2010
A coupled deformable model for tracking myocardial borders from real-time echocardiography using an incompressibility constraint
Zhu Y, Papademetris X, Sinusas AJ, Duncan JS. A coupled deformable model for tracking myocardial borders from real-time echocardiography using an incompressibility constraint. Medical Image Analysis 2010, 14: 429-448. PMID: 20350833, PMCID: PMC4318707, DOI: 10.1016/j.media.2010.02.005.Peer-Reviewed Original ResearchMeSH KeywordsAlgorithmsAnimalsArtificial IntelligenceComputer SystemsDogsEchocardiography, Three-DimensionalElasticity Imaging TechniquesHumansImage EnhancementImage Interpretation, Computer-AssistedPattern Recognition, AutomatedReproducibility of ResultsSensitivity and SpecificitySubtraction TechniqueConceptsDeformable modelImage-derived informationLV endocardial boundariesImage acquisition techniquesFinal segmentationAutomatic algorithmGround truthManual segmentationVolumetric imagesSegmentationSynthetic dataEndocardial boundaryNumber of effortsMyocardial bordersEpicardial boundariesAcquisition techniquesInstantaneous acquisitionConstraintsImagesEchocardiographic imagesSetSpeckle statisticsAlgorithmReal-time echocardiography
2009
A dynamical shape prior for LV segmentation from RT3D echocardiography.
Zhu Y, Papademetris X, Sinusas AJ, Duncan JS. A dynamical shape prior for LV segmentation from RT3D echocardiography. 2009, 12: 206-13. PMID: 20425989, PMCID: PMC7814293.Peer-Reviewed Original ResearchMeSH KeywordsAlgorithmsArtificial IntelligenceComputer SimulationComputer SystemsEchocardiography, Three-DimensionalHeart VentriclesHumansImage EnhancementImage Interpretation, Computer-AssistedImaging, Three-DimensionalModels, AnatomicPattern Recognition, AutomatedPhantoms, ImagingReproducibility of ResultsSensitivity and SpecificitySubtraction TechniqueConceptsSubject-specific dynamical modelCurrent frameMotion patternsRecursive Bayesian frameworkSegmentation taskPast framesAutomatic segmentationPrevious frameSegmentation processLV segmentationManual segmentationSegmentationIntensity informationCardiac sequenceEchocardiographic sequencesStatic modelPrior knowledgeTemporal coherenceCardiac motionCardiac modelsBayesian frameworkGeneric dynamical modelEchocardiographic imagesFrameInter-subject variability
2007
Challenges in image-guided therapy system design
DiMaio S, Kapur T, Cleary K, Aylward S, Kazanzides P, Vosburgh K, Ellis R, Duncan J, Farahani K, Lemke H, Peters T, Lorensen W, Gobbi D, Haller J, Clarke L, Pizer S, Taylor R, Galloway R, Fichtinger G, Hata N, Lawson K, Tempany C, Kikinis R, Jolesz F. Challenges in image-guided therapy system design. NeuroImage 2007, 37: s144-s151. PMID: 17644360, PMCID: PMC3780776, DOI: 10.1016/j.neuroimage.2007.04.026.Peer-Reviewed Original ResearchSegmentation of Myocardial Volumes from Real-Time 3D Echocardiography Using an Incompressibility Constraint
Zhu Y, Papademetris X, Sinusas A, Duncan JS. Segmentation of Myocardial Volumes from Real-Time 3D Echocardiography Using an Incompressibility Constraint. Lecture Notes In Computer Science 2007, 10: 44-51. PMID: 18051042, DOI: 10.1007/978-3-540-75757-3_6.Peer-Reviewed Original ResearchConceptsAutomatic segmentationImage-derived informationLV endocardial boundariesFinal representationManual segmentationSegmentationEndocardial boundaryEpicardial boundariesReal-time 3D echocardiographyTight couplingNew approachThree-dimensional shapeConstraintsVariety of effortsRepresentationInformationNew imaging modalitySet