2009
Transtelephonic Versus Remote Monitoring of Cardiovascular Implantable Electronic Devices Is One Approach to Be Preferred?⁎⁎Editorials published in the Journal of the American College of Cardiology reflect the views of the authors and do not necessarily represent the views of JACC or the American College of Cardiology.
Schoenfeld MH. Transtelephonic Versus Remote Monitoring of Cardiovascular Implantable Electronic Devices Is One Approach to Be Preferred?⁎⁎Editorials published in the Journal of the American College of Cardiology reflect the views of the authors and do not necessarily represent the views of JACC or the American College of Cardiology. Journal Of The American College Of Cardiology 2009, 54: 2020-2022. PMID: 19926007, DOI: 10.1016/j.jacc.2009.09.019.Peer-Reviewed Original Research
2005
Sophisticated Remote Implantable Cardioverter‐Defibrillator Follow‐Up: A Status Report
SCHOENFELD MH, REYNOLDS DW. Sophisticated Remote Implantable Cardioverter‐Defibrillator Follow‐Up: A Status Report. Pacing And Clinical Electrophysiology 2005, 28: 235-240. PMID: 15733185, DOI: 10.1111/j.1540-8159.2005.09554.x.Peer-Reviewed Original Research
2004
Remote Monitoring of Implantable Cardioverter Defibrillators:
SCHOENFELD MH, COMPTON SJ, MEAD RH, WEISS DN, SHERFESEE L, ENGLUND J, MONGEON LR. Remote Monitoring of Implantable Cardioverter Defibrillators:. Pacing And Clinical Electrophysiology 2004, 27: 757-763. PMID: 15189530, DOI: 10.1111/j.1540-8159.2004.00524.x.Peer-Reviewed Original ResearchConceptsImplantable cardioverter defibrillatorData transmissionCardioverter defibrillatorWeb access dataDevice dataRemote monitoring serviceStandard desktop computerAntiarrhythmic drug efficacyStudy support centerStandard telephone linesMonitor functionalityDesktop computerDevice managementSecure serverCareLink NetworkAF patientsICD patientsPatient websitesProspective studyInternet accessEase of useVentricular tachycardiaChronic diseasesInvestigational sitesDevice interrogation
2001
Inability to Communicate with ICDs: An Underreported Failure Mode
BLITZER M, MARIEB M, SCHOENFELD M. Inability to Communicate with ICDs: An Underreported Failure Mode. Pacing And Clinical Electrophysiology 2001, 24: 13-15. PMID: 11227962, DOI: 10.1046/j.1460-9592.2001.00013.x.Peer-Reviewed Original Research
1994
Troubleshooting Implantable Cardioverter Defibrillator System Malfunctions: The Role of Impedance Measurements
HADDAD L, PADULA L, MOREAU M, SCHOENFELD M. Troubleshooting Implantable Cardioverter Defibrillator System Malfunctions: The Role of Impedance Measurements. Pacing And Clinical Electrophysiology 1994, 17: 1456-1461. PMID: 7991415, DOI: 10.1111/j.1540-8159.1994.tb01509.x.Peer-Reviewed Original Research