1991
Assessment of potential contrast sensitivity Part 1: Preoperative prediction of contrast sensitivity following intraocular lens implantation
Morris M, Klett Z, Gieser S, Couch J, Hirsch J. Assessment of potential contrast sensitivity Part 1: Preoperative prediction of contrast sensitivity following intraocular lens implantation. Journal Of Cataract & Refractive Surgery 1991, 17: 37-44. PMID: 2005557, DOI: 10.1016/s0886-3350(13)80982-0.Peer-Reviewed Original ResearchConceptsPostoperative contrast sensitivity functionPreoperative visual acuityContrast sensitivity functionPreoperative visual acuity of 20/200Contrast sensitivityMild to moderate cataractsVisual acuity of 20/200Postoperative contrast sensitivityAcuity of 20/200Intraocular lens implantationModerate cataractLens implantationVisual acuityCataract patientsLens opacitiesPostoperative complicationsPreoperative measurementsPreoperative predictionCataractPatientsEyesAcuityComplicationsAssessment of contrast sensitivity Part II: The relationship between objective lens opacity and laser interferometric contrast sensitivity in the cataract patient
Klett Z, Morris M, Gieser S, Couch J, Hirsch J. Assessment of contrast sensitivity Part II: The relationship between objective lens opacity and laser interferometric contrast sensitivity in the cataract patient. Journal Of Cataract & Refractive Surgery 1991, 17: 45-57. PMID: 2005558, DOI: 10.1016/s0886-3350(13)80983-2.Peer-Reviewed Original ResearchConceptsLens opacitiesContrast sensitivityRetinal functionLaser interferometric measurementMeasure retinal functionPreoperative lens opacitiesRetinal contrast sensitivityOpacity lensmeterCataract densityCataract populationCataract patientsCataract typeImmature cataractCataractPatientsInverse linear relationshipOpacitySensitivityLensmeterCorrelation coefficient
1988
Assessment of retinal function in cataract patients by a combination of laser interferometry and conventional display methods to measure contrast sensitivity.
Jankelovits E, Lichtenstein S, Groll S, Remijan P, Hirsch J. Assessment of retinal function in cataract patients by a combination of laser interferometry and conventional display methods to measure contrast sensitivity. Applied Optics 1988, 27: 1057-63. PMID: 20531519, DOI: 10.1364/ao.27.001057.Peer-Reviewed Original ResearchMeasure retinal functionRetinal functionCompare contrast sensitivity functionLoss of visual functionMeasures of retinal functionAssessment of retinal functionMeasuring contrast sensitivityCataract patientsNormal eyesVisual functionCataractContrast sensitivityContrast sensitivity functionEye's opticsEyesContrast thresholdsConventional display methodContrast transfer functionLaser interferometryPatients