2018
The relationship between baseline and follow-up left ventricular ejection fraction with adverse events among primary prevention ICD patients
Friedman DJ, Fudim M, Overton R, Shaw LK, Patel D, Pokorney SD, Velazquez EJ, Al-Khatib SM. The relationship between baseline and follow-up left ventricular ejection fraction with adverse events among primary prevention ICD patients. American Heart Journal 2018, 201: 17-24. PMID: 29910051, PMCID: PMC6309220, DOI: 10.1016/j.ahj.2018.03.017.Peer-Reviewed Original ResearchConceptsLeft ventricular assist devicePrimary prevention ICD patientsAppropriate ICD therapyVentricular ejection fractionImplantable cardioverter defibrillatorICD therapyICD implantationEjection fractionICD patientsMultivariable Cox proportional hazards modelsPrimary prevention implantable cardioverter defibrillatorsCo-primary study endpointsPrimary prevention ICD recipientsFollow-up left ventricular ejection fractionLeft ventricular ejection fractionCox proportional hazards modelComposite of timeLong-term followProportional hazards modelVentricular assist deviceLong-term riskBaseline LVEFLVEF improvementAdverse eventsComposite endpoint
2016
Reassessment of Cardiac Function and Implantable Cardioverter-Defibrillator Use Among Medicare Patients With Low Ejection Fraction After Myocardial Infarction
Pokorney SD, Miller AL, Chen AY, Thomas L, Fonarow GC, de Lemos JA, Al-Khatib SM, Velazquez EJ, Peterson ED, Wang TY. Reassessment of Cardiac Function and Implantable Cardioverter-Defibrillator Use Among Medicare Patients With Low Ejection Fraction After Myocardial Infarction. Circulation 2016, 135: 38-47. PMID: 27881561, DOI: 10.1161/circulationaha.116.022359.Peer-Reviewed Original ResearchMeSH KeywordsAgedDatabases, FactualDefibrillators, ImplantableFemaleHeart VentriclesHumansMagnetic Resonance ImagingMaleMedicareMyocardial InfarctionMyocardial RevascularizationProportional Hazards ModelsRegistriesRetrospective StudiesStroke VolumeSurvival RateTomography, X-Ray ComputedUltrasonographyUnited StatesConceptsLow ejection fractionEjection fractionICD implantationMyocardial infarctionMI admissionsRevascularization statusImplantable cardioverter-defibrillator (ICD) useACTION Registry-GWTGICD implantation ratesMultivariable Cox modelPost-MI patientsYears of ageImplantation rateCardiac functionMedicare patientsCox modelPatientsAdmissionHigher likelihoodInfarctionImplantationAssociationYearsStatusICD
2013
Early Echocardiographic Deformation Analysis for the Prediction of Sudden Cardiac Death and Life-Threatening Arrhythmias After Myocardial Infarction
Ersbøll M, Valeur N, Andersen MJ, Mogensen UM, Vinther M, Svendsen JH, Møller JE, Kisslo J, Velazquez EJ, Hassager C, Søgaard P, Køber L. Early Echocardiographic Deformation Analysis for the Prediction of Sudden Cardiac Death and Life-Threatening Arrhythmias After Myocardial Infarction. JACC Cardiovascular Imaging 2013, 6: 851-860. PMID: 23850252, DOI: 10.1016/j.jcmg.2013.05.009.Peer-Reviewed Original ResearchMeSH KeywordsAgedArrhythmias, CardiacDeath, Sudden, CardiacDefibrillators, ImplantableDenmarkEchocardiographyElectric CountershockFemaleHumansMaleMiddle AgedMultivariate AnalysisMyocardial InfarctionPredictive Value of TestsPrimary PreventionProportional Hazards ModelsProspective StudiesRisk FactorsStroke VolumeTreatment OutcomeVentricular Function, LeftConceptsGlobal longitudinal strainAcute myocardial infarctionSudden cardiac deathMalignant ventricular arrhythmiasMyocardial infarctionNet reclassification indexVentricular arrhythmiasCardiac deathAddition of GLSMeasurement of GLSSCD/VAsChronic ischemic heart failureNovel echocardiographic parametersPrimary composite endpointPrimary composite outcomeIschemic heart failureEchocardiographic parametersPrimary endpointComposite outcomeHospital dischargeLate complicationsMultivariate adjustmentComposite endpointHeart failureRisk stratification
2012
Mechanical dyssynchrony evaluated by tissue Doppler cross-correlation analysis is associated with long-term survival in patients after cardiac resynchronization therapy
Risum N, Williams ES, Khouri MG, Jackson KP, Olsen NT, Jons C, Storm KS, Velazquez EJ, Kisslo J, Bruun NE, Sogaard P. Mechanical dyssynchrony evaluated by tissue Doppler cross-correlation analysis is associated with long-term survival in patients after cardiac resynchronization therapy. European Heart Journal 2012, 34: 48-56. PMID: 22390911, DOI: 10.1093/eurheartj/ehs035.Peer-Reviewed Original ResearchMeSH KeywordsAgedArrhythmias, CardiacCardiac Resynchronization TherapyCardiac Resynchronization Therapy DevicesCross-Sectional StudiesDefibrillators, ImplantableFeasibility StudiesFemaleHumansMaleMiddle AgedRetrospective StudiesStroke VolumeTreatment OutcomeUltrasonography, Doppler, ColorVentricular Dysfunction, LeftConceptsCardiac resynchronization therapyLong-term survivalMechanical dyssynchronyYu indexResynchronization therapyCox proportional hazards regressionLeft bundle branch blockProportional hazards regressionTissue Doppler imagingBundle branch blockPre-implant assessmentActivation delayVentricular assist deviceCardiac transplantationCause mortalityCRT candidatesImproved survivalHazards regressionPoor prognosisSubgroup analysisBranch blockWall delayPoor survivalDyssynchronyDoppler imaging
2011
Circumstances and Outcomes of Sudden Unexpected Death in Patients With High-Risk Myocardial Infarction
Ye S, Grunnert M, Thune JJ, Stephenson KM, Uno H, Finn PV, McMurray JJ, Velazquez EJ, Califf R, Pfeffer MA, Solomon SD. Circumstances and Outcomes of Sudden Unexpected Death in Patients With High-Risk Myocardial Infarction. Circulation 2011, 123: 2674-2680. PMID: 21606398, DOI: 10.1161/circulationaha.110.990655.Peer-Reviewed Original ResearchConceptsHigh-risk myocardial infarctionSudden deathMyocardial infarctionHospital eventsVentricular tachycardia/ventricular fibrillationPrevention of SDSD eventsLong-term mortalityMajority of patientsSudden unexpected deathInitial ECG rhythmCatastrophic complicationUnwitnessed arrestsUnexpected deathVentricular fibrillationTrial trialsPatientsInfarctionECG rhythmDeathPreventionHigher proportionHome eventsArrestSource documentation
2007
Racial Disparity in the Utilization of Implantable-Cardioverter Defibrillators Among Patients With Prior Myocardial Infarction and an Ejection Fraction of ≤35%
Thomas KL, Al-Khatib SM, Kelsey RC, Bush H, Brosius L, Velazquez EJ, Peterson ED, Gilliam FR. Racial Disparity in the Utilization of Implantable-Cardioverter Defibrillators Among Patients With Prior Myocardial Infarction and an Ejection Fraction of ≤35%. The American Journal Of Cardiology 2007, 100: 924-929. PMID: 17826371, DOI: 10.1016/j.amjcard.2007.04.024.Peer-Reviewed Original ResearchConceptsSudden cardiac deathLeft ventricular systolic dysfunctionVentricular systolic dysfunctionCardiac deathEjection fractionBlack patientsMyocardial infarctionSystolic dysfunctionWhite patientsPrimary preventionSignificant left ventricular systolic dysfunctionLower mean ejection fractionSudden cardiac death rateCardiac death rateMean ejection fractionPrior myocardial infarctionMultivariate logistic regressionImplantable cardioverter defibrillatorClinical characteristicsICD implantationICD useOverall mortalityProphylactic implantationPatient raceNational registry
2006
Letter by Bourque et al Regarding Article, “Changing Incidence and Survival for Heart Failure in a Well-Defined Older Population, 1970–1974 and 1990–1994”
Bourque JM, O’Connor C, Velazquez EJ. Letter by Bourque et al Regarding Article, “Changing Incidence and Survival for Heart Failure in a Well-Defined Older Population, 1970–1974 and 1990–1994”. Circulation 2006, 114: e255-e255. PMID: 16908779, DOI: 10.1161/circulationaha.106.632786.Peer-Reviewed Original ResearchMeSH KeywordsAgedAged, 80 and overCardiac Output, LowDefibrillators, ImplantableDrug TherapyFemaleHumansIncidenceMaleProportional Hazards ModelsSex FactorsSurvival RateSystole