2024
PET motion correction using subspace-based real-time MR imaging in simultaneous PET/MR
Mounime I, Marin T, Han P, Ouyang J, Gori P, Angelini E, Fakhri G, Ma C. PET motion correction using subspace-based real-time MR imaging in simultaneous PET/MR. 2024, 00: 1-1. DOI: 10.1109/nss/mic/rtsd57108.2024.10657647.Peer-Reviewed Original ResearchOrdered-subset expectation maximizationMotion correctionGated reconstructionsMotion-corrected PET reconstructionsPET eventsCardiac motion phasesMotion correction methodCardiac motionMotion phaseReconstructed dynamic imagesPET reconstructionReal-time MR imagingSimultaneous PET/MRPatient motionSoft tissue contrastDynamic MR image reconstructionReference phaseMitigate artifactsLow-rank propertyMR image reconstructionPositron emission tomographyManifold learning frameworkSpatial resolutionBlurring artifactsImage reconstruction
2011
Improvement in Lesion Detection with Whole-Body Oncologic Time-of-Flight PET
Fakhri G, Surti S, Trott C, Scheuermann J, Karp J. Improvement in Lesion Detection with Whole-Body Oncologic Time-of-Flight PET. Journal Of Nuclear Medicine 2011, 52: 347-353. PMID: 21321265, PMCID: PMC3088884, DOI: 10.2967/jnumed.110.080382.Peer-Reviewed Original ResearchConceptsTime-of-flight PETTime-of-flightTOF-PETTime-of-flight reconstructionBody mass indexList-mode dataNon-TOF PETObserver signal-to-noise ratioOrdered-subset expectation maximizationMass indexNon-TOFLesion detectionLesion detection performanceSpherical lesionsFunction of body mass indexSignal-to-noise ratioScan timePatient studiesLesion visibilityArtificial lesionsLiver lesionsPatientsLesionsLesion locationLow lesions
2007
Impact of Acquisition Geometry, Image Processing, and Patient Size on Lesion Detection in Whole-Body 18F-FDG PET
Fakhri G, Santos P, Badawi R, Holdsworth C, Van Den Abbeele A, Kijewski M. Impact of Acquisition Geometry, Image Processing, and Patient Size on Lesion Detection in Whole-Body 18F-FDG PET. Journal Of Nuclear Medicine 2007, 48: 1951-1960. PMID: 18006613, DOI: 10.2967/jnumed.108.007369.Peer-Reviewed Original ResearchConceptsAttenuation-weighted OSEMOrdered-subset expectation maximizationNoise equivalent countPhantom sizeBed positionCho SNRPatient sizeFourier rebinningAttenuation mapPET scannerLesion detectionMarginal detectionTransmission scanWhole-body (18)F-FDG PETAttenuation correctionWhole-body 18F-FDG PETHotelling observerScaling 2DSinogramReconstructed volumeDetection SNRPhantomSystematic improvementFBPScattering
2006
Fast Monte Carlo Simulation Based Joint Iterative Reconstruction for Simultaneous 99mTc/123I Brain SPECT Imaging
Ouyang J, Fakhri G, Moore S, Kijewski M. Fast Monte Carlo Simulation Based Joint Iterative Reconstruction for Simultaneous 99mTc/123I Brain SPECT Imaging. 2006, 4: 2251-2256. DOI: 10.1109/nssmic.2006.354362.Peer-Reviewed Original ResearchMC-JOSEMAW-OSEMMonte CarloFast Monte CarloIterative reconstructionOrdered-subset expectation maximizationStandard ordered subsetsIterative reconstruction algorithmScattered photonsPhoton transportSeptal penetrationAttenuation distributionPhysical effectsIdentical physiological conditionsPatient-specific activityReconstructed imagesReconstruction algorithmActivity estimationComptonRoot mean square errorPhotonsCorrection methodCollimatorBrain perfusionDetector
2001
Absolute activity quantitation in simultaneous 123I/99mTc brain SPECT.
El Fakhri G, Moore S, Maksud P, Aurengo A, Kijewski M. Absolute activity quantitation in simultaneous 123I/99mTc brain SPECT. Journal Of Nuclear Medicine 2001, 42: 300-8. PMID: 11216530.Peer-Reviewed Original ResearchMeSH KeywordsAlzheimer DiseaseBenzamidesBrainCerebellumCerebral CortexCerebrovascular CirculationCorpus CallosumHumansIodine RadioisotopesMonte Carlo MethodNeural Networks, ComputerParkinson DiseasePhantoms, ImagingPutamenPyrrolidinesRadiopharmaceuticalsSensitivity and SpecificityTechnetium Tc 99m ExametazimeTomography, Emission-Computed, Single-PhotonConceptsOrdered-subset expectation maximizationDistance-dependent collimator responseActivity quantitationActivity distributionIterative ordered-subsets expectation maximizationZubal brain phantomAsymmetric windowsSimulated normal populationPathological studiesDecay photonsBrain SPECTCollimator responseNonuniform attenuationDual-isotope imagingBrain phantomMonte Carlo simulationsCorpus callosumNormal populationPartial volume effectsCarlo simulationsCortical lobesAssessment of brain perfusionScatteringCross-talkBrain perfusion