Featured Publications
First-in-Human Evaluation of 18F-SynVesT-1, a Radioligand for PET Imaging of Synaptic Vesicle Glycoprotein 2A
Naganawa M, Li S, Nabulsi N, Henry S, Zheng MQ, Pracitto R, Cai Z, Gao H, Kapinos M, Labaree D, Matuskey D, Huang Y, Carson RE. First-in-Human Evaluation of 18F-SynVesT-1, a Radioligand for PET Imaging of Synaptic Vesicle Glycoprotein 2A. Journal Of Nuclear Medicine 2020, 62: 561-567. PMID: 32859701, PMCID: PMC8049363, DOI: 10.2967/jnumed.120.249144.Peer-Reviewed Original ResearchConceptsC-UCBSynaptic densityRegional time-activity curvesTime-activity curvesDistribution volumeMetabolite-corrected arterial input functionPET imagingMultilinear analysis 1Synaptic vesicle glycoprotein 2AAntiepileptic drug levetiracetamTotal distribution volumeNondisplaceable distribution volumeCentrum semiovaleBlocking doseHealthy volunteersHuman studiesDrug levetiracetamLassen plotNeuropsychiatric disordersPET radioligandArterial input functionNonhuman primatesLevetiracetamReference regionRadioligand
2024
Validation of a Simplified Tissue-to-Reference Ratio Measurement Using SUVR to Assess Synaptic Density Alterations in Alzheimer Disease with [11C]UCB-J PET
Young J, O’Dell R, Naganawa M, Toyonaga T, Chen M, Nabulsi N, Huang Y, Cooper E, Miller A, Lam J, Bates K, Ruan A, Nelsen K, Salardini E, Carson R, van Dyck C, Mecca A. Validation of a Simplified Tissue-to-Reference Ratio Measurement Using SUVR to Assess Synaptic Density Alterations in Alzheimer Disease with [11C]UCB-J PET. Journal Of Nuclear Medicine 2024, 65: jnumed.124.267419. PMID: 39299782, PMCID: PMC11533916, DOI: 10.2967/jnumed.124.267419.Peer-Reviewed Original ResearchDistribution volume ratioSUV ratioSynaptic densityEffect sizeAlzheimer's diseaseLongitudinal study of Alzheimer's diseaseMethods:</b> ParticipantsLongitudinal studyMeasure synaptic densityAD participantsStudy of Alzheimer's diseaseNormal cognitionReference regionOlder adultsMulticenterDensity alterationsNoninvasive quantification of [18F]SynVesT-1 binding using simplified reference tissue model 2
Naganawa M, Gallezot J, Li S, Nabulsi N, Henry S, Cai Z, Matuskey D, Huang Y, Carson R. Noninvasive quantification of [18F]SynVesT-1 binding using simplified reference tissue model 2. European Journal Of Nuclear Medicine And Molecular Imaging 2024, 1-9. PMID: 39155309, DOI: 10.1007/s00259-024-06885-6.Peer-Reviewed Original ResearchPositron emission tomographyCentrum semiovaleReference regionPositron emission tomography scanTest-retest variabilityTest-retest reproducibilitySynaptic vesicle glycoprotein 2AOne-tissue compartmentArterial blood samplesRetest scansGold standardBrain uptakeEmission tomographyBlood samplesCerebellumNoninvasive quantificationSRTM2ConclusionOur findingsPopulation averageHealthy participantsMetabolite analysisScan timeBPNDSemiovale
2023
Relationships of in vivo brain norepinephrine transporter and age, BMI, and gender
Koohsari S, Sadabad F, Pittman B, Gallezot J, Carson R, van Dyck C, Li C, Potenza M, Matuskey D. Relationships of in vivo brain norepinephrine transporter and age, BMI, and gender. Synapse 2023, 77: e22279. PMID: 37382240, PMCID: PMC10416616, DOI: 10.1002/syn.22279.Peer-Reviewed Original ResearchConceptsBody mass indexMultilinear reference tissue model 2Gender-related differencesBrain norepinephrine transportersNorepinephrine transporterAge-related declineStructural MR scansBrain regionsReference tissue model 2Mass indexRaphe nucleusLocus coeruleusOccipital cortexBMI relationshipHealthy adultsHigh-resolution research tomographAvailable radiotracersHealthy participantsMR scansAgeAnatomic templateReference regionNegative associationNet availabilityPotential age
2020
Quantification of SV2A Binding in Rodent Brain Using [18F]SynVesT-1 and PET Imaging
Sadasivam P, Fang XT, Toyonaga T, Lee S, Xu Y, Zheng MQ, Spurrier J, Huang Y, Strittmatter SM, Carson RE, Cai Z. Quantification of SV2A Binding in Rodent Brain Using [18F]SynVesT-1 and PET Imaging. Molecular Imaging And Biology 2020, 23: 372-381. PMID: 33258040, PMCID: PMC8105262, DOI: 10.1007/s11307-020-01567-9.Peer-Reviewed Original ResearchConceptsBrain stemAlzheimer's diseaseMin postinjectionAnimal modelsAPP/PS1 miceReference regionStandardized uptake value ratioDynamic PET imaging dataUptake value ratioRodent brain tissueStatic PET scansDifferent imaging windowsPET imaging dataWild-type controlsReference tissue modelPS1 miceAD pathogenesisTherapeutic effectMouse modelRodent modelsLittermate controlsPET scansRodent brainPreclinical imaging studiesTherapeutic drug efficacyFirst-in-Human Assessment of 11C-LSN3172176, an M1 Muscarinic Acetylcholine Receptor PET Radiotracer
Naganawa M, Nabulsi N, Henry S, Matuskey D, Lin SF, Slieker L, Schwarz AJ, Kant N, Jesudason C, Ruley K, Navarro A, Gao H, Ropchan J, Labaree D, Carson RE, Huang Y. First-in-Human Assessment of 11C-LSN3172176, an M1 Muscarinic Acetylcholine Receptor PET Radiotracer. Journal Of Nuclear Medicine 2020, 62: 553-560. PMID: 32859711, PMCID: PMC8049371, DOI: 10.2967/jnumed.120.246967.Peer-Reviewed Original ResearchConceptsSimplified reference tissue modelM1 receptorsHealthy subjectsMuscarinic acetylcholine receptor subtype M1Distribution volumePET radiotracersAbsolute test-retest variabilityExcellent test-retest reproducibilityReference tissue model 2Total distribution volumeSuitable reference regionTest-retest reproducibilityTest-retest variabilityReference regionTest-retest protocolNondisplaceable distribution volumeReference tissue modelTest-retest studySubtypes M1Preclinical studiesRegional time-activity curvesAcetylcholine concentrationHuman studiesReceptor occupancyTime-activity curves
2019
Assessment of a white matter reference region for 11C-UCB-J PET quantification
Rossano S, Toyonaga T, Finnema SJ, Naganawa M, Lu Y, Nabulsi N, Ropchan J, De Bruyn S, Otoul C, Stockis A, Nicolas JM, Martin P, Mercier J, Huang Y, Maguire RP, Carson RE. Assessment of a white matter reference region for 11C-UCB-J PET quantification. Cerebrovascular And Brain Metabolism Reviews 2019, 40: 1890-1901. PMID: 31570041, PMCID: PMC7446568, DOI: 10.1177/0271678x19879230.Peer-Reviewed Original ResearchEvaluation of 11C-LSN3172176 as a Novel PET Tracer for Imaging M1 Muscarinic Acetylcholine Receptors in Nonhuman Primates
Nabulsi NB, Holden D, Zheng MQ, Bois F, Lin SF, Najafzadeh S, Gao H, Ropchan J, Lara-Jaime T, Labaree D, Shirali A, Slieker L, Jesudason C, Barth V, Navarro A, Kant N, Carson RE, Huang Y. Evaluation of 11C-LSN3172176 as a Novel PET Tracer for Imaging M1 Muscarinic Acetylcholine Receptors in Nonhuman Primates. Journal Of Nuclear Medicine 2019, 60: 1147-1153. PMID: 30733324, DOI: 10.2967/jnumed.118.222034.Peer-Reviewed Original ResearchConceptsMuscarinic acetylcholine receptorsAcetylcholine receptorsNonhuman primatesM1 muscarinic acetylcholine receptorBrain time-activity curvesRich brain regionsArterial blood samplingNovel PET tracersSuitable reference regionRegional distribution volumesReference regionDevelopment of drugsBrain uptakeGlobus pallidusDistribution volume valuesNucleus accumbensBlood samplingPET scansTime-activity curvesCognitive impairmentAlzheimer's diseaseBrain regionsDistribution volumeSelective radiotracerRhesus monkeys
2015
Test–Retest Reproducibility of Binding Parameters in Humans with 11C-LY2795050, an Antagonist PET Radiotracer for the κ Opioid Receptor
Naganawa M, Zheng MQ, Henry S, Nabulsi N, Lin SF, Ropchan J, Labaree D, Najafzadeh S, Kapinos M, Tauscher J, Neumeister A, Carson RE, Huang Y. Test–Retest Reproducibility of Binding Parameters in Humans with 11C-LY2795050, an Antagonist PET Radiotracer for the κ Opioid Receptor. Journal Of Nuclear Medicine 2015, 56: 243-248. PMID: 25593119, PMCID: PMC4322754, DOI: 10.2967/jnumed.114.147975.Peer-Reviewed Original ResearchConceptsTest-retest variabilityOpioid receptorsOutcome measuresAbsolute test-retest variabilityMultilinear analysis 1Healthy human subjectsSuitable reference regionTest-retest reproducibilityIntraclass correlation coefficientAntagonist radiotracersHealthy subjectsLY2795050PET scansBrain regionsDistribution volumePET radioligandTest-retest performancePET studiesArterial input functionPET radiotracersHuman subjectsReference regionReceptorsVT valuesKOR