2021
First Transfemoral Implantation of a Novel Transcatheter Valve in an LVAD Patient With Aortic Insufficiency
Ranard LS, Kaple R, Khalique OK, Agarwal V, Bellumkonda L, Bonde P, George I, Uriel N, Leon MB, Vahl TP. First Transfemoral Implantation of a Novel Transcatheter Valve in an LVAD Patient With Aortic Insufficiency. JACC Case Reports 2021, 3: 1806-1810. PMID: 34917959, PMCID: PMC8642726, DOI: 10.1016/j.jaccas.2021.08.026.Peer-Reviewed Original ResearchTranscatheter valveSuccessful aortic valve replacementDecompensated heart failureSignificant aortic regurgitationAortic valve replacementVentricular assist deviceAortic insufficiencyAortic regurgitationLVAD patientsValve replacementHeart failureTransfemoral implantationClinical statusAssist deviceRegurgitationPatientsLVADInsufficiencyValve
2018
Fully Implantable Percutaneous Right Ventricular Assist Device via Direct Superior Vena Cava to Right Pulmonary Artery Connection
Park J, Bonde P. Fully Implantable Percutaneous Right Ventricular Assist Device via Direct Superior Vena Cava to Right Pulmonary Artery Connection. Journal Of The American College Of Surgeons 2018, 227: e91. DOI: 10.1016/j.jamcollsurg.2018.08.243.Peer-Reviewed Original Research
2017
Preliminary Design and Testing of a Cavo-Arterial Pump Utilizing Axial Magnetic Couplings
Valdovinos J, Bouwmeester J, Bonde P. Preliminary Design and Testing of a Cavo-Arterial Pump Utilizing Axial Magnetic Couplings. Journal Of Medical Devices 2017, 12: 011001. DOI: 10.1115/1.4038221.Peer-Reviewed Original ResearchRight ventricular assist deviceCirculatory supportMechanical circulatory support therapyAdequate circulatory supportRight ventricular dysfunctionHeart failure patientsPartial circulatory supportVentricular assist deviceIntravascular pumpVentricular dysfunctionFailure patientsSupport therapyPulmonary circulationPulmonary supportAssist deviceExtensive operationsAxial magnetic couplingBlood contactTorque transmissionDrive mechanismContactless torque transmissionHgDirect drive mechanismMagnetic drive mechanismMaximum pressure difference
2011
Powering a Ventricular Assist Device over Meter Distances Wirelessly: The Free-Range Resonant Electrical Energy Delivery (FREE-D) System
Waters B, Sample A, Kormos R, Smith J, Bonde P. Powering a Ventricular Assist Device over Meter Distances Wirelessly: The Free-Range Resonant Electrical Energy Delivery (FREE-D) System. Journal Of Cardiac Failure 2011, 17: s42-s43. DOI: 10.1016/j.cardfail.2011.06.144.Peer-Reviewed Original Research
2010
Cost-sensitive decision tree model for optimal identification of need for right ventricular support
Wang Y, Bonde P, Uber B, Teuteberg J, Kormos R, Antaki J. Cost-sensitive decision tree model for optimal identification of need for right ventricular support. IEEE Journal Of Biomedical And Health Informatics 2010, 1-4. DOI: 10.1109/itab.2010.5687641.Peer-Reviewed Original ResearchRight ventricular assist deviceLeft ventricular assist deviceVentricular assist deviceAssist deviceRight ventricular failureRight ventricular supportPittsburgh Medical CenterRV failureRVAD supportVentricular failureSignificant complicationsVentricular supportRetrospective analysisMedical CenterPatientsClinical expertsDecision tree modelComplicationsFailure