2016
Energy Modulated Photon Radiotherapy: A Monte Carlo Feasibility Study
Zhang Y, Feng Y, Ming X, Deng J. Energy Modulated Photon Radiotherapy: A Monte Carlo Feasibility Study. BioMed Research International 2016, 2016: 7319843. PMID: 26977413, PMCID: PMC4763028, DOI: 10.1155/2016/7319843.Peer-Reviewed Original ResearchConceptsIMRT plansPediatric brain tumorsNovel treatment modalitiesNormal tissue sparingDifferent tumor sitesDosimetric gainLung cancerTreatment modalitiesIndividual patientsBrain tumorsTissue sparingIMRT techniqueTumor sitePersonalized carePhoton radiotherapyThyroid lesionsDose distributionIntegral doseRadiotherapy treatmentInverse planning systemPatientsRadiotherapyFeasibility studyModern radiotherapy treatmentsClinical IMRT plans
2006
Potential impact of prostate edema on the dosimetry of permanent seed implants using the new (model CS‐1) seeds
Chen Z, Deng J, Roberts K, Nath R. Potential impact of prostate edema on the dosimetry of permanent seed implants using the new (model CS‐1) seeds. Medical Physics 2006, 33: 968-975. PMID: 16696473, DOI: 10.1118/1.2179170.Peer-Reviewed Original Research
2003
Commissioning 6 MV photon beams of a stereotactic radiosurgery system for Monte Carlo treatment planning
Deng J, Ma C, Hai J, Nath R. Commissioning 6 MV photon beams of a stereotactic radiosurgery system for Monte Carlo treatment planning. Medical Physics 2003, 30: 3124-3134. PMID: 14713079, DOI: 10.1118/1.1624753.Peer-Reviewed Original ResearchConceptsMonte Carlo dose calculationsMonte Carlo treatment planningBeam phase spaceOutput factorsCentral axis depth dose curvesDose profilesMonte Carlo treatmentMeasurement dataMultiple source modelCyberknife stereotactic radiosurgery systemPhase spaceMV photon beamDepth dose curvesDose calculationsSource modelStereotactic radiosurgery systemFluence distributionStandard measurement dataSource distributionPhoton beamsAxis distanceEnergy spectrumCollimator sizeDose curvesAveraging effectDose correlation for thoracic motion in radiation therapy of breast cancer
Ding M, Li J, Deng J, Fourkal E, Ma C. Dose correlation for thoracic motion in radiation therapy of breast cancer. Medical Physics 2003, 30: 2520-2529. PMID: 14528974, DOI: 10.1118/1.1603744.Peer-Reviewed Original ResearchMeSH KeywordsArtifactsBreast NeoplasmsHumansMammographyMotionMovementOnline SystemsPhantoms, ImagingRadiographic Image Interpretation, Computer-AssistedRadiography, ThoracicRadiometryRadiotherapy DosageRadiotherapy Planning, Computer-AssistedRadiotherapy, Computer-AssistedReproducibility of ResultsRespirationSensitivity and SpecificityStatistics as TopicThoraxTomography, X-Ray ComputedConceptsBreathing patternDose correlationBreast cancerChest wall motionChest wall movementPatient's breathing patternDose dataRadiation therapyThoracic motionRadiotherapy treatmentTreatment planningExpiration phaseDifferent breathing phasesFinal dose distributionCancerBreathing phasesPatient anatomyWall motionTreatmentDose distributionCT dataBreathing levelTherapyDosePatient geometryA comparative dosimetric study on tangential photon beams, intensity-modulated radiation therapy (IMRT) and modulated electron radiotherapy (MERT) for breast cancer treatment
Ma C, Ding M, Li JS, Lee MC, Pawlicki T, Deng J. A comparative dosimetric study on tangential photon beams, intensity-modulated radiation therapy (IMRT) and modulated electron radiotherapy (MERT) for breast cancer treatment. Physics In Medicine And Biology 2003, 48: 909-924. PMID: 12701895, DOI: 10.1088/0031-9155/48/7/308.Peer-Reviewed Original ResearchConceptsIntensity-modulated radiation therapyTangential photon beamsContralateral breastBreast cancerRadiation therapyTreatment planMaximum doseBreast cancer treatmentTreatment optimizationComparative dosimetric studyBreast treatment plansPhoton treatment plansPhoton beamsElectron radiotherapySuperficial targetsMultiple beam anglesLungMedium dosesDose conformityTangential beamsNormal tissuesCancer treatmentMERT plansIMRT plansMV photon beamA quality assurance phantom for IMRT dose verification
Ma C, Jiang SB, Pawlicki T, Chen Y, Li JS, Deng J, Boyer AL. A quality assurance phantom for IMRT dose verification. Physics In Medicine And Biology 2003, 48: 561-572. PMID: 12696795, DOI: 10.1088/0031-9155/48/5/301.Peer-Reviewed Original Research
2002
A Monte Carlo investigation of fluence profiles collimated by an electron specific MLC during beam delivery for modulated electron radiation therapy
Deng J, Lee MC, Ma C. A Monte Carlo investigation of fluence profiles collimated by an electron specific MLC during beam delivery for modulated electron radiation therapy. Medical Physics 2002, 29: 2472-2483. PMID: 12462711, DOI: 10.1118/1.1513160.Peer-Reviewed Original ResearchConceptsFluence profilesVarian Clinac 2100C linear acceleratorElectron radiation therapyElectron beamMonte Carlo methodBeam energyBeam deliveryMonte Carlo investigationElectron beam energyCarlo methodMonte CarloOff-axis locationBEAM codeSigmoid functionLeaf endsEnergy dependenceInverse planning algorithmLinear acceleratorVariable energyMLC aperturesOperatorsBeamField sizeDose distributionMultileaf collimator
2001
The MLC tongue-and-groove effect on IMRT dose distributions
Deng J, Pawlicki T, Chen Y, Li J, Jiang S, Ma C. The MLC tongue-and-groove effect on IMRT dose distributions. Physics In Medicine And Biology 2001, 46: 1039-1060. PMID: 11324950, DOI: 10.1088/0031-9155/46/4/310.Peer-Reviewed Original Research
2000
Energy- and intensity-modulated electron beams for radiotherapy
Ma C, Pawlicki T, Lee MC, Jiang SB, Li JS, Deng J, Yi B, Mok E, Boyer AL. Energy- and intensity-modulated electron beams for radiotherapy. Physics In Medicine And Biology 2000, 45: 2293-2311. PMID: 10958195, DOI: 10.1088/0031-9155/45/8/316.Peer-Reviewed Original ResearchConceptsModulated electron radiotherapyIntensity-modulated electron beamElectron beamMultileaf collimatorElectron beam energyInter-leaf leakageDose distributionElectron intraMonte Carlo dose calculationsPencil beam algorithmLeaf endsBeam energyPhoton beamsElectron radiotherapyOblique incidencePatient surfaceMonte Carlo methodBeamBeam algorithmField shapeMonte Carlo simulationsDose calculationsSuperficial targetsCarlo methodCarlo simulations