2021
Impact of reconstruction parameters on lesion detection and localization in joint ictal/inter-ictal SPECT reconstruction
Onwanna J, Chantadisai M, Tepmongkol S, Fahey F, Ouyang J, Rakvongthai Y. Impact of reconstruction parameters on lesion detection and localization in joint ictal/inter-ictal SPECT reconstruction. Annals Of Nuclear Medicine 2021, 36: 24-32. PMID: 34559366, DOI: 10.1007/s12149-021-01680-x.Peer-Reviewed Original ResearchConceptsLocalization receiver operating characteristicsDetection performanceSubtraction methodJoint methodOptimization iterationsLesion detection performanceSPECT reconstructionEpileptic focus localizationLocalization receiver operating characteristic curvesDifferential imagingInter-ictalLesion detectionIterationPhantom dataConventional subtraction methodPerformanceImagesPatient datasetsReconstruction parametersImpact of reconstruction parametersFocus localizationSubtractionDetectionSPECT dataJoint reconstruction
2014
Relative role of motion and PSF compensation in whole‐body oncologic PET‐MR imaging
Petibon Y, Huang C, Ouyang J, Reese T, Li Q, Syrkina A, Chen Y, Fakhri G. Relative role of motion and PSF compensation in whole‐body oncologic PET‐MR imaging. Medical Physics 2014, 41: 042503. PMID: 24694156, PMCID: PMC3971824, DOI: 10.1118/1.4868458.Peer-Reviewed Original ResearchConceptsPoint spread function modelRespiratory motionPoint spread functionPET-MR scannersPencil-beam navigator echoesPET-MRMeasurement of respiratory motionPSF modelRespiratory motion correctionDetector blur effectsModel respiratory motionLung-liver interfacePatient studiesLesion contrastSimultaneous PET-MRSource of image degradationWhole-body PET imagingPET reconstruction algorithmMoving lesionsPhantom experiment resultsPET eventsContrast recoveryNavigator echoesIterative reconstruction processMotion correctionMyocardial Defect Detection Using PET-CT: Phantom Studies
Mananga E, Fakhri G, Schaefferkoetter J, Bonab A, Ouyang J. Myocardial Defect Detection Using PET-CT: Phantom Studies. PLOS ONE 2014, 9: e88200. PMID: 24505429, PMCID: PMC3914931, DOI: 10.1371/journal.pone.0088200.Peer-Reviewed Original ResearchConceptsMyocardial defect detectionFiltered back projectionChannelized Hotelling observerPhantom studyActivity distributionSubset expectation maximizationDefect detectionCardiac PET studiesMyocardial defectsHotelling observerNoise levelBack-projectionPET-CTPhantomExpectation maximizationOP-OSEMReconstruction schemePET studiesOSEMDefectsNoise
2012
MRI-Based Nonrigid Motion Correction in Simultaneous PET/MRI
Chun Y, Reese T, Ouyang J, Guerin B, Catana C, Zhu X, Alpert N, Fakhri G. MRI-Based Nonrigid Motion Correction in Simultaneous PET/MRI. Journal Of Nuclear Medicine 2012, 53: 1284-1291. PMID: 22743250, PMCID: PMC4077320, DOI: 10.2967/jnumed.111.092353.Peer-Reviewed Original ResearchConceptsChannelized Hotelling observerMotion correctionDetection signal-to-noise ratioSignal-to-noise ratioMRI-based motion correctionRespiratory motion correctionMotion-corrected reconstructionOrdered-subsets expectation maximization algorithmNonrigid motion correctionChannelized Hotelling observer studyPET image qualityNonrigid image registration methodCoincidence dataDeformable phantomRespiratory gatingReduce radiation doseDynamic phantomImage registration methodReduced signal-to-noise ratioSimultaneous PET/MRICost of increased noiseHotelling observerPhantomAttenuation measurementsRabbit studies