2021
A layered single-side readout depth of interaction time-of-flight-PET detector
Bläckberg L, Sajedi S, Fakhri G, Sabet H. A layered single-side readout depth of interaction time-of-flight-PET detector. Physics In Medicine And Biology 2021, 66: 045025. PMID: 33570050, PMCID: PMC8130834, DOI: 10.1088/1361-6560/abd592.Peer-Reviewed Original ResearchConceptsDepth of interactionMulti-pixel photon counterDepth-of-interaction determinationDepth-of-interaction informationTime resolutionTime resolution valuesReduced crystal thicknessNon-DOI detectorsOptical photonsScintillator arrayPET detectorsPhoton counterCrystal pixelsReadout schemeCrystal arrayCrystal thicknessTransport simulationsDetectorPhotodetector arrayReadoutPixel sizePhotodetectorsResolution valuesFirst layerSignal amplitude
2005
Collimator Optimization for Detection and Quantitation Tasks: Application to Gallium-67 Imaging
Moore S, Kijewski M, Fakhri G. Collimator Optimization for Detection and Quantitation Tasks: Application to Gallium-67 Imaging. IEEE Transactions On Medical Imaging 2005, 24: 1347-1356. PMID: 16229420, DOI: 10.1109/tmi.2005.857211.Peer-Reviewed Original ResearchMeSH KeywordsCitratesComputer SimulationComputer-Aided DesignEquipment DesignEquipment Failure AnalysisGalliumHumansImage EnhancementImage Interpretation, Computer-AssistedModels, BiologicalNeoplasmsPhantoms, ImagingPositron-Emission TomographyRadiopharmaceuticalsReproducibility of ResultsSensitivity and SpecificityConceptsMedium-energy low-penetration collimatorCollimator optimizationGeometric spatial resolutionPhotopeak energy windowSimulation of photon transportLead X-raysClinical imaging tasksActivity estimation taskSignal-to-noise ratioGallium-67 imagingContaminating photonsEnergy windowGeometric efficiencyCollimator designFixed energyPhoton transportOptimal collimatorCollimatorHotelling observerFWHMSpatial resolutionNuclear medicineDetectorResolution valuesImaging tasks
2002
Optimal Parallel-Hole Collimation for Lesion Detection and Activity Estimation in Ga-67 Imaging
Moore S, Kijewski M, Fakhri G. Optimal Parallel-Hole Collimation for Lesion Detection and Activity Estimation in Ga-67 Imaging. 2002, 3: 1390-1392. DOI: 10.1109/nssmic.2002.1239580.Peer-Reviewed Original ResearchCollimator designMedium-energy (MESimulation of photon transportSignal-to-noise ratioParallel-hole collimatorDesign of collimatorsClinical imaging tasksGa-67Contaminating photonsField of nuclear medicineEnergy windowFixed energyPhoton transportOptimal collimatorCollimatorCommercial collimatorsStaging of lymphoma patientsHotelling observerGa-67 imagingNuclear medicine clinicsLesion detectionNuclear medicineDetectorActivity concentrationsResolution values