2024
Free‐breathing 3D cardiac extracellular volume (ECV) mapping using a linear tangent space alignment (LTSA) model
Lee W, Han P, Marin T, Mounime I, Eslahi S, Djebra Y, Chi D, Bijari F, Normandin M, Fakhri G, Ma C. Free‐breathing 3D cardiac extracellular volume (ECV) mapping using a linear tangent space alignment (LTSA) model. Magnetic Resonance In Medicine 2024 PMID: 39402014, DOI: 10.1002/mrm.30284.Peer-Reviewed Original ResearchExtracellular volume mappingContrast agent injectionExtracellular volumeGradient echo readoutECV mapsAgent injectionWhole heartEcho readoutExtracellular volume valuesVoxel-by-voxelInversion recovery sequenceSpatial resolutionScan timeImaging timeIn vivo studiesHealthy volunteersModel-based methodsRecovery sequenceInjectionReadout
2023
Arterial spin labeled perfusion imaging with balanced steady-state free precession readout and radial sampling
Han P, Marin T, Zhuo Y, Ouyang J, El Fakhri G, Ma C. Arterial spin labeled perfusion imaging with balanced steady-state free precession readout and radial sampling. Magnetic Resonance Imaging 2023, 102: 126-132. PMID: 37187264, PMCID: PMC10524790, DOI: 10.1016/j.mri.2023.05.005.Peer-Reviewed Original ResearchConceptsOff-resonance effectsBalanced steady-state free precessionPhase-cycling techniqueTemporal SNRBalanced steady-state free precession acquisitionRadial sampling schemeSpoiled gradient-recalled acquisitionRadial samplingCartesian sampling schemeBalanced steady-state free precession readoutK-space dataSampling schemeSpin labelingSteady-state free precessionK-spaceImage readoutBanding artifactsMotion-related artifactsReadoutFree precessionArterial spin labelingImage reconstructionParallel imagingImaging timePerfusion-weighted imaging
2021
A layered single-side readout depth of interaction time-of-flight-PET detector
Bläckberg L, Sajedi S, Fakhri G, Sabet H. A layered single-side readout depth of interaction time-of-flight-PET detector. Physics In Medicine And Biology 2021, 66: 045025. PMID: 33570050, PMCID: PMC8130834, DOI: 10.1088/1361-6560/abd592.Peer-Reviewed Original ResearchConceptsDepth of interactionMulti-pixel photon counterDepth-of-interaction determinationDepth-of-interaction informationTime resolutionTime resolution valuesReduced crystal thicknessNon-DOI detectorsOptical photonsScintillator arrayPET detectorsPhoton counterCrystal pixelsReadout schemeCrystal arrayCrystal thicknessTransport simulationsDetectorPhotodetector arrayReadoutPixel sizePhotodetectorsResolution valuesFirst layerSignal amplitude
2019
New Detector Designs for High Resolution Brain PET
Bläckberg L, Sajedi S, Fakhri G, Sabet H. New Detector Designs for High Resolution Brain PET. 2019, 00: 1-5. DOI: 10.1109/nss/mic42101.2019.9059785.Peer-Reviewed Original ResearchLaser induced optical barriersLYSO:Ce crystalsScintillation light spreadIntrinsic resolutionDetector designCe crystalsOptical barrierBrain positron emission tomographyScintillationCrystal thicknessPhotodetector elementsTransverse resolutionDetectorPositron emission tomographyPhotodetectorsImproved positionLYSOCrystalReadoutResolutionLaserDependenceEmission tomography