2022
Balanced Steady‐State Free Precession Cine MR Imaging in the Presence of Cardiac Devices: Value of Interleaved Radial Linear Combination Acquisition With Partial Dephasing
Xiang J, Lamy J, Lampert R, Peters D. Balanced Steady‐State Free Precession Cine MR Imaging in the Presence of Cardiac Devices: Value of Interleaved Radial Linear Combination Acquisition With Partial Dephasing. Journal Of Magnetic Resonance Imaging 2022, 58: 782-791. PMID: 36373998, PMCID: PMC11238270, DOI: 10.1002/jmri.28528.Peer-Reviewed Original Research
2019
Left atrial fibrosis correlates with extent of left ventricular myocardial delayed enhancement and left ventricular strain in hypertrophic cardiomyopathy
Latif SR, Nguyen VQ, Peters DC, Soufer A, Henry ML, Grunseich K, Testani J, Hur DJ, Huber S, Mojibian H, Dicks D, Sinusas AJ, Meadows JL, Papoutsidakis N, Jacoby D, Baldassarre LA. Left atrial fibrosis correlates with extent of left ventricular myocardial delayed enhancement and left ventricular strain in hypertrophic cardiomyopathy. The International Journal Of Cardiovascular Imaging 2019, 35: 1309-1318. PMID: 30790116, DOI: 10.1007/s10554-019-01551-7.Peer-Reviewed Original ResearchMeSH KeywordsAdultAgedAngiotensin Receptor AntagonistsAngiotensin-Converting Enzyme InhibitorsAtrial Function, LeftAtrial RemodelingCardiomyopathy, HypertrophicContrast MediaFemaleFibrosisHeart AtriaHeart VentriclesHumansHypertrophy, Left VentricularMagnetic Resonance Imaging, CineMaleMiddle AgedOrganometallic CompoundsPredictive Value of TestsRetrospective StudiesVentricular Dysfunction, LeftVentricular Function, LeftVentricular RemodelingConceptsLA fibrosisLV-LGEHypertrophic cardiomyopathyLA-LGELV fibrosisLV parametersLV end-diastolic volumeSetting of HCMAldosterone system inhibitionLate gadolinium enhancement (LGE) sequencesLV global strainLeft ventricular massEnd-diastolic volumeLeft atrial fibrosisMaximum wall thicknessFibrosis correlatesRenin-AngiotensinVentricular strainMedication usageAtrial fibrosisLV remodelingVentricular massLV massSystem inhibitionDiastolic volume
2017
Reverse double inversion‐recovery: Improving motion robustness of cardiac T2‐weighted dark‐blood turbo spin‐echo sequence
Hu C, Huber S, Latif SR, Santacana‐Laffitte G, Mojibian HR, Baldassarre LA, Peters DC. Reverse double inversion‐recovery: Improving motion robustness of cardiac T2‐weighted dark‐blood turbo spin‐echo sequence. Journal Of Magnetic Resonance Imaging 2017, 47: 1498-1508. PMID: 29112315, PMCID: PMC6346424, DOI: 10.1002/jmri.25886.Peer-Reviewed Original ResearchAdultAgedAlgorithmsArtifactsComputer SimulationDiastoleFemaleHealthy VolunteersHeartHeart DiseasesHeart VentriclesHumansImage EnhancementImage Interpretation, Computer-AssistedImage Processing, Computer-AssistedMagnetic Resonance ImagingMaleMiddle AgedMotionMyocardiumProspective StudiesQuality ControlReproducibility of ResultsSignal-To-Noise Ratio
2014
Algebraic reconstruction technique for parallel imaging reconstruction of undersampled radial data: Application to cardiac cine
Li S, Chan C, Stockmann JP, Tagare H, Adluru G, Tam LK, Galiana G, Constable RT, Kozerke S, Peters DC. Algebraic reconstruction technique for parallel imaging reconstruction of undersampled radial data: Application to cardiac cine. Magnetic Resonance In Medicine 2014, 73: 1643-1653. PMID: 24753213, PMCID: PMC4504217, DOI: 10.1002/mrm.25265.Peer-Reviewed Original Research
2009
Association of Thrombolysis in Myocardial Infarction Myocardial Perfusion Grade with cardiovascular magnetic resonance measures of infarct architecture after primary percutaneous coronary intervention for ST-segment elevation myocardial infarction
Appelbaum E, Abraham JM, Pride YB, Harrigan CJ, Peters DC, Biller LH, Manning WJ, Gibson CM. Association of Thrombolysis in Myocardial Infarction Myocardial Perfusion Grade with cardiovascular magnetic resonance measures of infarct architecture after primary percutaneous coronary intervention for ST-segment elevation myocardial infarction. American Heart Journal 2009, 158: 84-91. PMID: 19540396, DOI: 10.1016/j.ahj.2009.04.012.Peer-Reviewed Original ResearchMeSH KeywordsAdultAgedAngioplasty, Balloon, CoronaryCardiac VolumeContrast MediaCoronary AngiographyCoronary CirculationElectrocardiographyEndocardiumFemaleGadolinium DTPAHeart VentriclesHumansImage Processing, Computer-AssistedMagnetic Resonance ImagingMaleMiddle AgedMyocardial InfarctionMyocardial Reperfusion InjuryMyocardiumPericardiumPrognosisSignal Processing, Computer-AssistedThrombolytic TherapyTreatment OutcomeConceptsST-segment elevation myocardial infarctionPrimary percutaneous coronary interventionMyocardial perfusion gradeInfarct border zoneMyocardial Infarction (TIMI) myocardial perfusion gradeElevation myocardial infarctionPercutaneous coronary interventionInfarct sizePerfusion gradeMyocardial perfusionInfarct surface areaCoronary interventionMyocardial infarctionInfarct architectureCardiovascular magnetic resonance measuresNormal epicardial flowDays of presentationMagnetic resonance measuresCardiovascular magnetic resonanceImpaired thrombolysisEpicardial flowThrombolysisPatientsPerfusionTMPG
2004
Reduced field of view and undersampled PR combined for interventional imaging of a fully dynamic field of view
Peters DC, Guttman MA, Dick AJ, Raman VK, Lederman RJ, McVeigh ER. Reduced field of view and undersampled PR combined for interventional imaging of a fully dynamic field of view. Magnetic Resonance In Medicine 2004, 51: 761-767. PMID: 15065249, PMCID: PMC2034278, DOI: 10.1002/mrm.20037.Peer-Reviewed Original ResearchConceptsTemporal filtering techniquesTemporal resolutionField of viewArtifact suppressionFiltering techniqueTrue frameGood temporal resolutionAccurate monitoringProjection reconstructionMRI experimentsCatheter imagingImage artifactsInterventional imagingDynamic fieldDynamic eventsImage qualityFieldProcessingFOVResolutionRFOVSimulations
2003
Undersampled projection reconstruction for active catheter imaging with adaptable temporal resolution and catheter‐only views
Peters DC, Lederman RJ, Dick AJ, Raman VK, Guttman MA, Derbyshire JA, McVeigh ER. Undersampled projection reconstruction for active catheter imaging with adaptable temporal resolution and catheter‐only views. Magnetic Resonance In Medicine 2003, 49: 216-222. PMID: 12541240, PMCID: PMC2396305, DOI: 10.1002/mrm.10390.Peer-Reviewed Original Research