2019
Direct List Mode Parametric Reconstruction for Dynamic Cardiac SPECT
Shi L, Lu Y, Wu J, Gallezot JD, Boutagy N, Thorn S, Sinusas AJ, Carson RE, Liu C. Direct List Mode Parametric Reconstruction for Dynamic Cardiac SPECT. IEEE Transactions On Medical Imaging 2019, 39: 119-128. PMID: 31180845, PMCID: PMC7030971, DOI: 10.1109/tmi.2019.2921969.Peer-Reviewed Original ResearchConceptsAppropriate kinetic modelConventional indirect methodImage reconstruction algorithmKinetic modelHigh noise levelsLow count levelsVivo canine studyIndirect methodImage noiseNoise levelParametric reconstructionNoiseReconstruction algorithmFrame imagePatient radiation dose reductionMethodDirect methodLower image noise
2016
Quantitative Analysis of Dynamic 123I-mIBG SPECT Imaging Data in Healthy Humans with a Population-Based Metabolite Correction Method
Wu J, Lin SF, Gallezot JD, Chan C, Prasad R, Thorn S, Stacy MR, Huang Y, Zonouz TH, Liu YH, Lampert RJ, Carson RE, Sinusas AJ, Liu C. Quantitative Analysis of Dynamic 123I-mIBG SPECT Imaging Data in Healthy Humans with a Population-Based Metabolite Correction Method. Journal Of Nuclear Medicine 2016, 57: 1226-1232. PMID: 27081169, DOI: 10.2967/jnumed.115.171710.Peer-Reviewed Original Research3-IodobenzylguanidineAdultAgedAlgorithmsArtifactsComputer SimulationFemaleHeartHumansImage EnhancementImage Interpretation, Computer-AssistedMaleMiddle AgedModels, CardiovascularModels, StatisticalMyocardiumRadiopharmaceuticalsReproducibility of ResultsSensitivity and SpecificityTissue DistributionTomography, Emission-Computed, Single-Photon
2015
Scatter and crosstalk corrections for 99mTc/123I dual‐radionuclide imaging using a CZT SPECT system with pinhole collimators
Fan P, Hutton BF, Holstensson M, Ljungberg M, Pretorius P, Prasad R, Ma T, Liu Y, Wang S, Thorn SL, Stacy MR, Sinusas AJ, Liu C. Scatter and crosstalk corrections for 99mTc/123I dual‐radionuclide imaging using a CZT SPECT system with pinhole collimators. Medical Physics 2015, 42: 6895-6911. PMID: 26632046, DOI: 10.1118/1.4934830.Peer-Reviewed Original ResearchConceptsDual-radionuclide imagingCrosstalk correction methodTEW methodLine source experimentDefect contrastSource experimentsMonte Carlo simulationsIncomplete charge collectionCadmium zinc telluride detectorsLow-energy tailImaging systemCarlo simulationsPinhole collimatorCardiac SPECT systemEnergy tailDetector effectsEnergy spectrumPoint source measurementsSPECT systemCZT detectorsTriple energy window (TEW) methodScatter modelDedicated cardiac SPECT systemsCorrection methodCrosstalk correction
2009
The impact of respiratory motion on tumor quantification and delineation in static PET/CT imaging
Liu C, Pierce LA, Alessio AM, Kinahan PE. The impact of respiratory motion on tumor quantification and delineation in static PET/CT imaging. Physics In Medicine And Biology 2009, 54: 7345-7362. PMID: 19926910, PMCID: PMC2895622, DOI: 10.1088/0031-9155/54/24/007.Peer-Reviewed Original Research