2021
Free‐breathing 3D cardiac T1 mapping with transmit B1 correction at 3T
Han P, Marin T, Djebra Y, Landes V, Zhuo Y, Fakhri G, Ma C. Free‐breathing 3D cardiac T1 mapping with transmit B1 correction at 3T. Magnetic Resonance In Medicine 2021, 87: 1832-1845. PMID: 34812547, PMCID: PMC8810588, DOI: 10.1002/mrm.29097.Peer-Reviewed Original ResearchMeSH KeywordsHeartHumansImage Interpretation, Computer-AssistedMagnetic Resonance ImagingPhantoms, ImagingReproducibility of ResultsConceptsFlip-angle estimationCardiac T<sub>1</sub> mappingGradient echo readoutThrough-plane spatial resolutionImaging timePractical imaging timesFree breathingPhantom studyB1 correctionAccelerated imagingIn-planeT)-spaceMyocardial T<sub>1</sub> valuesSubspace-based methodsSpatial resolutionImaging experimentsAcquisition schemeT)-space dataSubject-specific timeCorrectionModified Look-Locker inversion recoveryLook-Locker inversion recoveryTime of data acquisitionAverage imaging timeInversion-recovery sequence
2015
High‐resolution 1H‐MRSI of the brain using SPICE: Data acquisition and image reconstruction
Lam F, Ma C, Clifford B, Johnson C, Liang Z. High‐resolution 1H‐MRSI of the brain using SPICE: Data acquisition and image reconstruction. Magnetic Resonance In Medicine 2015, 76: 1059-1070. PMID: 26509928, PMCID: PMC4848237, DOI: 10.1002/mrm.26019.Peer-Reviewed Original ResearchMeSH KeywordsAlgorithmsBrainHumansImage EnhancementImage Interpretation, Computer-AssistedMagnetic Resonance ImagingProton Magnetic Resonance SpectroscopyReproducibility of ResultsSensitivity and SpecificitySignal Processing, Computer-AssistedConceptsSubspace structureSpectroscopic imaging sequenceImage reconstructionSubspace modelImage sequencesImage reconstruction purposesEdge-preserving regularizationData acquisitionReconstruction methodThrough-plane resolutionImage reconstruction methodIn-planeIn vivo brain experimentsEncoding schemeField inhomogeneity correctionIn-plane resolutionTwo-dimensional (2DImaging frameworkInhomogeneity correctionData setsSubspaceHigh-resolutionHybrid data setsSpatial resolutionBrain experiments
2014
Design of multidimensional Shinnar–Le Roux radiofrequency pulses
Ma C, Liang Z. Design of multidimensional Shinnar–Le Roux radiofrequency pulses. Magnetic Resonance In Medicine 2014, 73: 633-645. PMID: 24578212, PMCID: PMC4147023, DOI: 10.1002/mrm.25179.Peer-Reviewed Original ResearchMeSH KeywordsAlgorithmsImage EnhancementImage Interpretation, Computer-AssistedMagnetic Resonance ImagingMagnetic Resonance SpectroscopyPhantoms, ImagingRadio WavesReproducibility of ResultsSensitivity and SpecificitySignal Processing, Computer-Assisted
2012
Reduced field‐of‐view excitation using second‐order gradients and spatial‐spectral radiofrequency pulses
Ma C, Xu D, King K, Liang Z. Reduced field‐of‐view excitation using second‐order gradients and spatial‐spectral radiofrequency pulses. Magnetic Resonance In Medicine 2012, 69: 503-508. PMID: 22489022, PMCID: PMC3406253, DOI: 10.1002/mrm.24259.Peer-Reviewed Original ResearchMeSH KeywordsAlgorithmsImage EnhancementImage Interpretation, Computer-AssistedPhantoms, ImagingRadio WavesReproducibility of ResultsSensitivity and SpecificitySignal Processing, Computer-AssistedConceptsRF pulsesRF pulse lengthSpatially selective radiofrequencyReduced field-of-view imagingBloch equation simulationsField-of-view imagingPulse lengthRadiofrequency pulsesPhantom experimentsSelective radiofrequencyEquation simulationsPulseSecond-order gradientsNonlinear gradientsExcitation accuracyRegion-of-interestSpatial selectivityBlochSpatial dependencePhantom
2010
Joint design of spoke trajectories and RF pulses for parallel excitation
Ma C, Xu D, King K, Liang Z. Joint design of spoke trajectories and RF pulses for parallel excitation. Magnetic Resonance In Medicine 2010, 65: 973-985. PMID: 21413061, DOI: 10.1002/mrm.22676.Peer-Reviewed Original ResearchMeSH KeywordsAlgorithmsImage EnhancementImage Interpretation, Computer-AssistedMagnetic Resonance ImagingPhantoms, ImagingReproducibility of ResultsSensitivity and SpecificityConceptsJoint design problemExcitation errorsTransmitting sensitivityJoint designCost function evaluationsExcitation systemDesign problemRF pulse designSelection problemMultidimensional RF pulsesExperimental resultsComputational efficiencyRF pulsesPulse designThin slice selectionEquation simulationsBloch equation simulationsSequential selectionConventional methodsSpoke locationExcitation patternsK-spacePulseFunction evaluationsLength limit
2009
Perturbation Analysis of the Effects of $B_{1}^{+}$ Errors on Parallel Excitation in MRI
Ma C, Xu D, King K, Liang Z. Perturbation Analysis of the Effects of $B_{1}^{+}$ Errors on Parallel Excitation in MRI. Annual International Conference Of The IEEE Engineering In Medicine And Biology Society (EMBC) 2009, 1: 4064-4066. PMID: 19964100, DOI: 10.1109/iembs.2009.5333196.Peer-Reviewed Original Research