2018
Sex disparities in acute myocardial infarction care and outcomes
Gul B, Kozuma K, Haimi I, Zhao W, Simonton C, Ying S, Buda A, Mehta S, Baumbach A, Lansky A. Sex disparities in acute myocardial infarction care and outcomes. Catheterization And Cardiovascular Interventions 2018, 92: e341-e347. PMID: 29745453, DOI: 10.1002/ccd.27622.Peer-Reviewed Original ResearchMeSH KeywordsAgedChinaClinical Trials as TopicFemaleHealthcare DisparitiesHemorrhageHumansJapanMaleMiddle AgedNon-ST Elevated Myocardial InfarctionPercutaneous Coronary InterventionProduct Surveillance, PostmarketingRegistriesRetrospective StudiesRisk AssessmentRisk FactorsSex FactorsST Elevation Myocardial InfarctionStentsTime FactorsTreatment OutcomeUnited StatesConceptsMajor adverse cardiac eventsAcute myocardial infarctionPercutaneous coronary interventionTarget vessel failureCause mortalityXience V stentMajor bleedingUS patientsHigher major adverse cardiac eventsSetting of AMIContemporary percutaneous coronary interventionAcute myocardial infarction careDevice-specific outcomesAdverse cardiac eventsMyocardial infarction carePost-market registryCause deathCardiac eventsCoronary interventionMultivariable analysisFemale sexMyocardial infarctionPatient levelSex disparitiesPatientsComparison of Physician Visual Assessment With Quantitative Coronary Angiography in Assessment of Stenosis Severity in China
Zhang H, Mu L, Hu S, Nallamothu BK, Lansky AJ, Xu B, Bouras G, Cohen DJ, Spertus JA, Masoudi FA, Curtis JP, Gao R, Ge J, Yang Y, Li J, Li X, Zheng X, Li Y, Krumholz HM, Jiang L. Comparison of Physician Visual Assessment With Quantitative Coronary Angiography in Assessment of Stenosis Severity in China. JAMA Internal Medicine 2018, 178: 239-247. PMID: 29340571, PMCID: PMC5838612, DOI: 10.1001/jamainternmed.2017.7821.Peer-Reviewed Original ResearchMeSH KeywordsAgedAged, 80 and overChinaCoronary AngiographyCoronary StenosisCoronary VesselsCross-Sectional StudiesFemaleFollow-Up StudiesHumansIncidenceMaleMiddle AgedPercutaneous Coronary InterventionPractice Patterns, Physicians'Predictive Value of TestsProspective StudiesRisk AssessmentSeverity of Illness IndexTime FactorsConceptsPhysician visual assessmentPercutaneous coronary interventionAcute myocardial infarctionQuantitative coronary angiographyStenosis severityCoronary angiographyMean agePCI studiesMean percent diameter stenosisIndependent core laboratoryPercent diameter stenosisCross-sectional studyNon-AMI patientsStandard clinical practiceFractional flow reserveSubset of participantsQCA assessmentCoronary revascularizationMore stenosisCoronary interventionCoronary lesionsChina PatientCoronary angiogramDiameter stenosisMyocardial infarction
2016
Diagnostic Accuracy of Fast Computational Approaches to Derive Fractional Flow Reserve From Diagnostic Coronary Angiography The International Multicenter FAVOR Pilot Study
Tu S, Westra J, Yang J, von Birgelen C, Ferrara A, Pellicano M, Nef H, Tebaldi M, Murasato Y, Lansky A, Barbato E, van der Heijden LC, Reiber JH, Holm NR, Wijns W, Group F. Diagnostic Accuracy of Fast Computational Approaches to Derive Fractional Flow Reserve From Diagnostic Coronary Angiography The International Multicenter FAVOR Pilot Study. JACC Cardiovascular Interventions 2016, 9: 2024-2035. PMID: 27712739, DOI: 10.1016/j.jcin.2016.07.013.Peer-Reviewed Original ResearchMeSH KeywordsAdenosineAdministration, IntravenousAgedArea Under CurveBlood Flow VelocityCardiac CatheterizationChinaComputer SimulationCoronary AngiographyCoronary StenosisCoronary VesselsEuropeFeasibility StudiesFemaleFractional Flow Reserve, MyocardialHumansHyperemiaJapanMaleMiddle AgedModels, CardiovascularMyocardial Perfusion ImagingPilot ProjectsPredictive Value of TestsPrognosisProspective StudiesRadiographic Image Interpretation, Computer-AssistedRegional Blood FlowReproducibility of ResultsROC CurveSeverity of Illness IndexTime FactorsUnited StatesVasodilator AgentsWorkflowConceptsQuantitative flow ratioHyperemic flow velocityReceiver-operating characteristic curveCoronary angiographyDiagnostic accuracyAngiographic percent diameter stenosisDiagnostic coronary angiographyProspective multicenter studyIndependent core laboratoryAdenosine-induced hyperemiaPercent diameter stenosisQuantitative coronary angiographyIntermediate coronary lesionsCharacteristic curveFractional flow reservePositive likelihood ratioOverall diagnostic accuracyNegative likelihood ratioDrug-induced hyperemiaLikelihood ratioCoronary lesionsMulticenter studyDiameter stenosisMaximal hyperemiaFlow reserve
2015
Safety and efficacy of a novel abluminal groove‐filled biodegradable polymer sirolimus‐eluting stent for the treatment of de novo coronary lesions: Two‐year results from a prospective patient‐level pooled analysis of TARGET trials
Gao Z, Zhang R, Xu B, Yang Y, Ma C, Li H, Chen S, Han Y, Yuan Z, Lansky AJ, Guan C, Leon MB, Gao R, Investigators F. Safety and efficacy of a novel abluminal groove‐filled biodegradable polymer sirolimus‐eluting stent for the treatment of de novo coronary lesions: Two‐year results from a prospective patient‐level pooled analysis of TARGET trials. Catheterization And Cardiovascular Interventions 2015, 85: 734-743. PMID: 25678281, DOI: 10.1002/ccd.25861.Peer-Reviewed Original ResearchMeSH KeywordsAbsorbable ImplantsAgedCardiovascular AgentsChinaCoronary Artery DiseaseDrug-Eluting StentsFemaleHumansKaplan-Meier EstimateMaleMiddle AgedMyocardial InfarctionPercutaneous Coronary InterventionPolymersProspective StudiesProsthesis DesignRandomized Controlled Trials as TopicRegistriesRisk FactorsSirolimusTime FactorsTreatment OutcomeConceptsTarget lesion failureFIREHAWK stentStent thrombosisCoronary lesionsMyocardial infarctionNovel abluminal groove-filled biodegradable polymer sirolimus-eluting stentDe novo native coronary lesionsBiodegradable polymer sirolimus-eluting stentsDe novo coronary lesionsPatient-level pooled analysisTarget vessel myocardial infarctionNew drug-eluting stentsNative coronary lesionsNovo coronary lesionsProbable stent thrombosisTarget lesion revascularizationVessel myocardial infarctionSirolimus-eluting stentsPatient-level analysisPatient-level dataLong-term safetyDrug-eluting stentsTwo-year resultsObjective performance criteriaLesion revascularization
2013
A randomised comparison of a novel abluminal groove-filled biodegradable polymer sirolimus-eluting stent with a durable polymer everolimus-eluting stent: clinical and angiographic follow-up of the TARGET I trial.
Gao RL, Xu B, Lansky AJ, Yang YJ, Ma CS, Han YL, Chen SL, Li H, Zhang RY, Fu GS, Yuan ZY, Jiang H, Huo Y, Li W, Zhang YJ, Leon MB. A randomised comparison of a novel abluminal groove-filled biodegradable polymer sirolimus-eluting stent with a durable polymer everolimus-eluting stent: clinical and angiographic follow-up of the TARGET I trial. EuroIntervention 2013, 9: 75-83. PMID: 23685298, DOI: 10.4244/eijv9i1a12.Peer-Reviewed Original ResearchMeSH KeywordsAbsorbable ImplantsAgedAnalysis of VarianceAntineoplastic AgentsChinaChi-Square DistributionCoronary AngiographyCoronary Artery DiseaseCoronary RestenosisCoronary StenosisCoronary ThrombosisDrug-Eluting StentsEverolimusFemaleHumansLeast-Squares AnalysisMaleMiddle AgedMyocardial InfarctionPercutaneous Coronary InterventionPolymersPredictive Value of TestsProspective StudiesProsthesis DesignSirolimusTime FactorsTreatment OutcomeConceptsIschaemia-driven target lesion revascularisationStent late lumen lossTarget vessel myocardial infarctionLate lumen lossTarget lesion failureSingle de novo coronary lesionsDe novo coronary lesionsNovo coronary lesionsCoronary lesionsPrimary endpointCardiac deathI trialNovel abluminal groove-filled biodegradable polymer sirolimus-eluting stentSingle de novo native coronary lesionsDe novo native coronary lesionsBiodegradable polymer sirolimus-eluting stentsNine monthsNative coronary lesionsProbable stent thrombosisTarget lesion revascularisationVessel myocardial infarctionSirolimus-eluting stentsNon-inferiority trialLesion revascularisationEES group