2020
Clinical outcome after interventions with paclitaxel-coated balloons: a PCR statement.
Lansky A, Cremonesi A, Scheller B, James S, Grubman D, Fajadet J, Sauguet A, Micari A, Sarno G, Bosiers M, Baumbach A, Wijns W. Clinical outcome after interventions with paclitaxel-coated balloons: a PCR statement. EuroIntervention 2020, 15: 1225-1227. PMID: 32044731, DOI: 10.4244/eijv15i14a220.Peer-Reviewed Original Research
2019
First-in-Human Study of Paclitaxel Drug-Coated Chocolate Coronary Percutaneous Transluminal Coronary Angioplasty Balloon Catheter in De Novo Coronary Artery Lesions
Garcia-Lithgow C, Tirziu D, Zhou S, Bouras G, Shah T, Grubman D, Javier JJ, Mustapha JA, Abizaid A, Lansky AJ. First-in-Human Study of Paclitaxel Drug-Coated Chocolate Coronary Percutaneous Transluminal Coronary Angioplasty Balloon Catheter in De Novo Coronary Artery Lesions. JACC Cardiovascular Interventions 2019, 12: 2568-2570. PMID: 31857033, DOI: 10.1016/j.jcin.2019.08.044.Peer-Reviewed Original ResearchClinical outcomes of complex lesions treated with an abluminal groove‐filled biodegradable polymer sirolimus‐eluting stent and durable polymer everolimus‐eluting stent
Saito Y, Baumbach A, Wijns W, Xu B, Kelbæk H, Zheng M, Morel M, Anderson R, Schächinger V, Lansky A, Investigators T. Clinical outcomes of complex lesions treated with an abluminal groove‐filled biodegradable polymer sirolimus‐eluting stent and durable polymer everolimus‐eluting stent. Catheterization And Cardiovascular Interventions 2019, 96: 1023-1028. PMID: 31769161, DOI: 10.1002/ccd.28609.Peer-Reviewed Original ResearchConceptsHigh-risk patientsClinical outcomesComer studyI trialDurable polymer everolimus-eluting stentsTarget vessel myocardial infarctionSirolimus-eluting coronary stentYear clinical outcomesTarget lesion failureVessel myocardial infarctionLow-risk patientsWorse clinical outcomesEverolimus-eluting stentsHigh-risk groupLow-risk groupStrict eligibility criteriaFIREHAWK stentLesion failurePrimary endpointRandomized trialsMyocardial infarctionRisk groupsInclusion criteriaComplex lesionsXIENCE stent2-Year Clinical Outcomes of an Abluminal Groove–Filled Biodegradable-Polymer Sirolimus-Eluting Stent Compared With a Durable-Polymer Everolimus-Eluting Stent
Xu B, Saito Y, Baumbach A, Kelbæk H, van Royen N, Zheng M, Morel MA, Knaapen P, Slagboom T, Johnson TW, Vlachojannis G, Arkenbout KE, Holmvang L, Janssens L, Ochala A, Brugaletta S, Naber CK, Anderson R, Rittger H, Berti S, Barbato E, Toth GG, Maillard L, Valina C, Buszman P, Thiele H, Schächinger V, Lansky A, Wijns W, Investigators T. 2-Year Clinical Outcomes of an Abluminal Groove–Filled Biodegradable-Polymer Sirolimus-Eluting Stent Compared With a Durable-Polymer Everolimus-Eluting Stent. JACC Cardiovascular Interventions 2019, 12: 1679-1687. PMID: 31129092, DOI: 10.1016/j.jcin.2019.05.001.Peer-Reviewed Original ResearchMeSH KeywordsAbsorbable ImplantsAgedCardiovascular AgentsCoronary Artery DiseaseCoronary ThrombosisDrug-Eluting StentsDual Anti-Platelet TherapyEuropeEverolimusFemaleHumansMaleMiddle AgedPercutaneous Coronary InterventionPolymersProspective StudiesProsthesis DesignRisk FactorsSirolimusTime FactorsTreatment OutcomeConceptsTarget lesion failureXIENCE stentXience groupLesion failurePrimary endpointClinical outcomesIschemia-driven target lesion revascularizationTarget vessel myocardial infarctionProbable stent thrombosisTarget lesion revascularizationVessel myocardial infarctionLong-term outcomesDurable polymer everolimusBiodegradable Polymer SirolimusAbluminal grooveFIREHAWK stentLesion revascularizationCardiac deathComparable safetyStent thrombosisMyocardial infarctionClinical trialsEfficacy profileNoninferiority trialLandmark analysis
2016
Clinical outcomes after PCI treatment of very long lesions with the XIENCE V everolimus eluting stent; Pooled analysis from the SPIRIT and XIENCE V USA prospective multicenter trials
Bouras G, Jhamnani S, Ng VG, Haimi I, Mao V, Deible R, Cao S, Sudhir K, Lansky AJ. Clinical outcomes after PCI treatment of very long lesions with the XIENCE V everolimus eluting stent; Pooled analysis from the SPIRIT and XIENCE V USA prospective multicenter trials. Catheterization And Cardiovascular Interventions 2016, 89: 984-991. PMID: 27545721, DOI: 10.1002/ccd.26711.Peer-Reviewed Original ResearchConceptsMajor adverse cardiac eventsLong coronary lesionsTarget lesion failurePercutaneous coronary interventionAcademic Research ConsortiumMean lesion lengthCoronary lesionsXIENCE VCoronary interventionStent thrombosisLesion lengthRate of TLFControl groupSecond generation drug eluting stentsLong lesion groupAdverse cardiac eventsProbable stent thrombosisPrimary outcome measureCoronary stent systemDrug eluting stentsLesion failureCardiac eventsPooled analysisWorse outcomesLesion group
2015
Bioabsorbable polymer‐coated sirolimus‐eluting stent implantation preserves coronary vasomotion: A DESSOLVE II trial sub‐study
Rusinaru D, Vrolix M, Verheye S, Chowdhary S, Schoors D, Di Mario C, Desmet W, Donohoe DJ, Ormiston JA, Knape C, Bezerra H, Lansky A, Wijns W, Investigators O. Bioabsorbable polymer‐coated sirolimus‐eluting stent implantation preserves coronary vasomotion: A DESSOLVE II trial sub‐study. Catheterization And Cardiovascular Interventions 2015, 86: 1141-1150. PMID: 25044635, DOI: 10.1002/ccd.25610.Peer-Reviewed Original ResearchMeSH KeywordsAbsorbable ImplantsAgedCardiac Pacing, ArtificialCardiovascular AgentsCoronary AngiographyCoronary Artery DiseaseCoronary VesselsDrug-Eluting StentsEuropeFemaleHistorically Controlled StudyHumansMaleMiddle AgedNew ZealandPercutaneous Coronary InterventionPolymersProspective StudiesSingle-Blind MethodSirolimusTime FactorsTreatment OutcomeVasoconstrictionVasodilationConceptsZotarolimus-eluting stentsDrug-eluting stentsCoronary vasomotionII trialVasomotor dysfunctionFirst-generation drug-eluting stentsEndeavor zotarolimus-eluting stentsGeneration drug-eluting stentsCoronary vasomotor dysfunctionSirolimus-eluting stentsQuantitative coronary angiographyVessel diameterMaximal pacingCoronary angiographyZES groupCoronary arteryVasomotor responsesHistorical groupStent edgeNormal vasomotionPatientsPercent changeReference segmentsVasomotionSES groupSafety and efficacy of a novel abluminal groove‐filled biodegradable polymer sirolimus‐eluting stent for the treatment of de novo coronary lesions: Two‐year results from a prospective patient‐level pooled analysis of TARGET trials
Gao Z, Zhang R, Xu B, Yang Y, Ma C, Li H, Chen S, Han Y, Yuan Z, Lansky AJ, Guan C, Leon MB, Gao R, Investigators F. Safety and efficacy of a novel abluminal groove‐filled biodegradable polymer sirolimus‐eluting stent for the treatment of de novo coronary lesions: Two‐year results from a prospective patient‐level pooled analysis of TARGET trials. Catheterization And Cardiovascular Interventions 2015, 85: 734-743. PMID: 25678281, DOI: 10.1002/ccd.25861.Peer-Reviewed Original ResearchMeSH KeywordsAbsorbable ImplantsAgedCardiovascular AgentsChinaCoronary Artery DiseaseDrug-Eluting StentsFemaleHumansKaplan-Meier EstimateMaleMiddle AgedMyocardial InfarctionPercutaneous Coronary InterventionPolymersProspective StudiesProsthesis DesignRandomized Controlled Trials as TopicRegistriesRisk FactorsSirolimusTime FactorsTreatment OutcomeConceptsTarget lesion failureFIREHAWK stentStent thrombosisCoronary lesionsMyocardial infarctionNovel abluminal groove-filled biodegradable polymer sirolimus-eluting stentDe novo native coronary lesionsBiodegradable polymer sirolimus-eluting stentsDe novo coronary lesionsPatient-level pooled analysisTarget vessel myocardial infarctionNew drug-eluting stentsNative coronary lesionsNovo coronary lesionsProbable stent thrombosisTarget lesion revascularizationVessel myocardial infarctionSirolimus-eluting stentsPatient-level analysisPatient-level dataLong-term safetyDrug-eluting stentsTwo-year resultsObjective performance criteriaLesion revascularization
2013
First-in-Human Evaluation of a Bioabsorbable Polymer–Coated Sirolimus-Eluting Stent Imaging and Clinical Results of the DESSOLVE I Trial (DES With Sirolimus and a Bioabsorbable Polymer for the Treatment of Patients With De Novo Lesion in the Native Coronary Arteries)
Ormiston J, Webster M, Stewart J, Vrolix M, Whitbourn R, Donohoe D, Knape C, Lansky A, Attizzani GF, Fitzgerald P, Kandzari DE, Wijns W. First-in-Human Evaluation of a Bioabsorbable Polymer–Coated Sirolimus-Eluting Stent Imaging and Clinical Results of the DESSOLVE I Trial (DES With Sirolimus and a Bioabsorbable Polymer for the Treatment of Patients With De Novo Lesion in the Native Coronary Arteries). JACC Cardiovascular Interventions 2013, 6: 1026-1034. PMID: 24055443, DOI: 10.1016/j.jcin.2013.05.013.Peer-Reviewed Original ResearchMeSH KeywordsAbsorbable ImplantsAdultAgedAged, 80 and overAngina, StableAngina, UnstableAustraliaBelgiumCardiovascular AgentsChromium AlloysCoronary AngiographyCoronary Artery DiseaseCoronary RestenosisCoronary StenosisCoronary VesselsDrug Therapy, CombinationDrug-Eluting StentsFemaleHumansMaleMiddle AgedMyocardial InfarctionNeointimaNew ZealandPercutaneous Coronary InterventionPlatelet Aggregation InhibitorsPolymersProspective StudiesProsthesis DesignSeverity of Illness IndexSirolimusTime FactorsTomography, Optical CoherenceTreatment OutcomeUltrasonography, InterventionalConceptsStent late lumen lossLate lumen lossSirolimus-eluting stentsOptical coherence tomographyIntravascular ultrasoundMajor adverse cardiac eventsSymptomatic coronary artery diseaseCoherence tomographyComplete strut coverageNeointimal volume obstructionUnderwent repeat angiographyAdverse cardiac eventsDual antiplatelet therapyCoronary artery diseaseUnstable angina pectorisDrug-eluting stentsLong-term riskAntiplatelet therapyVolume obstructionCardiac eventsRepeat angiographyAdverse eventsAngina pectorisArtery diseaseI trialMeta-Analysis of Everolimus-Eluting Versus Paclitaxel-Eluting Stents in Coronary Artery Disease Final 3-Year Results of the SPIRIT Clinical Trials Program (Clinical Evaluation of the Xience V Everolimus Eluting Coronary Stent System in the Treatment of Patients With De Novo Native Coronary Artery Lesions)
Dangas GD, Serruys PW, Kereiakes DJ, Hermiller J, Rizvi A, Newman W, Sudhir K, Smith RS, Cao S, Theodoropoulos K, Cutlip DE, Lansky AJ, Stone GW. Meta-Analysis of Everolimus-Eluting Versus Paclitaxel-Eluting Stents in Coronary Artery Disease Final 3-Year Results of the SPIRIT Clinical Trials Program (Clinical Evaluation of the Xience V Everolimus Eluting Coronary Stent System in the Treatment of Patients With De Novo Native Coronary Artery Lesions). JACC Cardiovascular Interventions 2013, 6: 914-922. PMID: 24050859, DOI: 10.1016/j.jcin.2013.05.005.Peer-Reviewed Original ResearchMeSH KeywordsAgedCardiovascular AgentsCoronary Artery DiseaseCoronary RestenosisCoronary ThrombosisDrug-Eluting StentsEverolimusFemaleHumansKaplan-Meier EstimateMaleMiddle AgedMulticenter Studies as TopicMultivariate AnalysisMyocardial InfarctionPaclitaxelPercutaneous Coronary InterventionProportional Hazards ModelsProsthesis DesignRandomized Controlled Trials as TopicRisk FactorsSirolimusTime FactorsTreatment OutcomeConceptsPaclitaxel-eluting stentsIschemia-driven target lesion revascularizationMajor adverse cardiac eventsAdverse cardiac eventsTarget lesion revascularizationLesion failureMyocardial infarctionLesion revascularizationCause mortalityCardiac eventsStent thrombosisStent typeEvent ratesTarget lesion failureClinical trial programException of diabetesIndividual patient dataIndividual clinical outcomesCardiac deathComposite endpointClinical outcomesSPIRIT IIClinical trialsCoronary implantationTrial programImpact of advanced age on the safety and effectiveness of paclitaxel‐eluting stent implantation in patients with ST‐segment elevation myocardial infarction undergoing primary angioplasty
Dudek D, Mehran R, Dziewierz A, Witzenbichler B, Brodie BR, Kornowski R, Fahy M, Lansky AJ, Rakowski T, Legutko J, Bryniarski L, Stone GW. Impact of advanced age on the safety and effectiveness of paclitaxel‐eluting stent implantation in patients with ST‐segment elevation myocardial infarction undergoing primary angioplasty. Catheterization And Cardiovascular Interventions 2013, 82: 869-877. PMID: 23359554, DOI: 10.1002/ccd.24813.Peer-Reviewed Original ResearchConceptsPrimary percutaneous coronary interventionST-segment elevation myocardial infarctionPaclitaxel-eluting stent implantationPrimary PCIBare metal stentsElevation myocardial infarctionYears of ageStent implantationOlder patientsMyocardial infarctionLower riskIschemic target vessel revascularizationMajor adverse cardiac eventsHORIZONS-AMI studyHORIZONS-AMI trialReduction of MACEAdverse cardiac eventsTarget vessel revascularizationClinical end pointsPercutaneous coronary interventionLong-term resultsImpact of ageCause deathMajor bleedingPrimary angioplastyDrug eluting balloons for de novocoronary lesions – a systematic review and meta-analysis
Fröhlich GM, Lansky AJ, Ko DT, Archangelidi O, De Palma R, Timmis A, Meier P. Drug eluting balloons for de novocoronary lesions – a systematic review and meta-analysis. BMC Medicine 2013, 11: 123. PMID: 23657123, PMCID: PMC3648374, DOI: 10.1186/1741-7015-11-123.Peer-Reviewed Original ResearchMeSH KeywordsCardiovascular AgentsCoronary Artery DiseaseDrug Delivery SystemsHumansPaclitaxelRandomized Controlled Trials as TopicTreatment OutcomeConceptsMajor adverse cardiac eventsNovo coronary lesionsTarget lesion revascularizationBare metal stentsLate lumen lossDrug-eluting balloonsDe novo coronary lesionsCurrent standard therapyDrug-Eluting BalloonRelative riskCoronary lesionsStent thrombosisMyocardial infarctionStandard therapyStent restenosisSystematic reviewLower late lumen lossAdverse cardiac eventsPooled relative riskRandom-effects modelLesion revascularizationSegment restenosisCardiac eventsComparator treatmentResultsEight studies
2011
Impact of Lesion Length and Vessel Size on Clinical Outcomes After Percutaneous Coronary Intervention With Everolimus- Versus Paclitaxel-Eluting Stents Pooled Analysis From the SPIRIT (Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System) and COMPARE (Second-generation everolimus-eluting and paclitaxel-eluting stents in real-life practice) Randomized Trials
Claessen BE, Smits PC, Kereiakes DJ, Parise H, Fahy M, Kedhi E, Serruys PW, Lansky AJ, Cristea E, Sudhir K, Sood P, Simonton CA, Stone GW. Impact of Lesion Length and Vessel Size on Clinical Outcomes After Percutaneous Coronary Intervention With Everolimus- Versus Paclitaxel-Eluting Stents Pooled Analysis From the SPIRIT (Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System) and COMPARE (Second-generation everolimus-eluting and paclitaxel-eluting stents in real-life practice) Randomized Trials. JACC Cardiovascular Interventions 2011, 4: 1209-1215. PMID: 22115661, DOI: 10.1016/j.jcin.2011.07.016.Peer-Reviewed Original ResearchMeSH KeywordsAgedAngioplasty, Balloon, CoronaryCardiovascular AgentsChi-Square DistributionCoronary AngiographyCoronary StenosisDrug-Eluting StentsEverolimusFemaleHumansKaplan-Meier EstimateMaleMiddle AgedMyocardial InfarctionPaclitaxelPredictive Value of TestsProportional Hazards ModelsProsthesis DesignRandomized Controlled Trials as TopicRisk AssessmentRisk FactorsSeverity of Illness IndexSirolimusThrombosisTime FactorsTreatment OutcomeConceptsMajor adverse cardiac eventsPaclitaxel-eluting stentsReference vessel diameterEverolimus-eluting stentsPercutaneous coronary interventionLong lesionsGroup BLesion lengthMACE rateCoronary interventionSmall vesselsGroup AStent typeShort lesionsAdverse cardiac eventsHigh-risk patientsPatient-level dataLarge vesselsLower ratesCOMPARE trialLesion revascularizationEfficacy outcomesAdverse eventsCardiac eventsIndependent predictors
2010
Side branch occlusion with everolimus-eluting and paclitaxel-eluting stents: three-year results from the SPIRIT III randomised trial.
Lansky AJ, Yaqub M, Hermiller JB, Smith RS, Farhat N, Caputo R, Williams JE, Sanz M, Koo K, Sood P, Sudhir K, Stone GW. Side branch occlusion with everolimus-eluting and paclitaxel-eluting stents: three-year results from the SPIRIT III randomised trial. EuroIntervention 2010, 6 Suppl J: j44-52. PMID: 21930490, DOI: 10.4244/eijv6supja8.Peer-Reviewed Original ResearchMeSH KeywordsAgedAngioplasty, Balloon, CoronaryCardiovascular AgentsCoronary AngiographyCoronary Artery DiseaseCoronary RestenosisDrug-Eluting StentsEverolimusFemaleHumansKaplan-Meier EstimateMaleMiddle AgedMyocardial InfarctionPaclitaxelProspective StudiesProsthesis DesignRisk AssessmentRisk FactorsSingle-Blind MethodSirolimusTime FactorsTreatment OutcomeUnited StatesConceptsPeriprocedural myocardial infarctionSide branch occlusionBranch occlusionMyocardial infarctionStent placementDrug-eluting stent placementIndependent angiographic core laboratoryPaclitaxel-eluting stent placementLong-term adverse outcomesSPIRIT III trialPaclitaxel-eluting stentsAngiographic core laboratoryThree-year resultsLower ratesSide branchesEES armIII trialsMI ratesIndependent predictorsClinical outcomesAdverse outcomesProcedural angiogramsGrade 0Stent typeCore laboratoryEvaluation of the effects of everolimus‐eluting and paclitaxel‐eluting stents on target lesions with jailed side branches: 2‐year results from the SPIRIT III randomized trial
Applegate R, Hermiller J, Williams J, Gordon P, Doostzadeh J, Cao S, Su X, Sudhir K, Lansky A, Simonton C, Stone G. Evaluation of the effects of everolimus‐eluting and paclitaxel‐eluting stents on target lesions with jailed side branches: 2‐year results from the SPIRIT III randomized trial. Catheterization And Cardiovascular Interventions 2010, 76: 644-651. PMID: 20506356, DOI: 10.1002/ccd.22606.Peer-Reviewed Original ResearchMeSH KeywordsAgedAngioplasty, Balloon, CoronaryBiomarkersCardiovascular AgentsCoronary AngiographyCoronary Artery DiseaseCreatine Kinase, MB FormDrug-Eluting StentsEverolimusFemaleHumansKaplan-Meier EstimateMaleMiddle AgedMyocardial InfarctionMyocardiumNecrosisPaclitaxelProspective StudiesProsthesis DesignRisk AssessmentRisk FactorsSeverity of Illness IndexSingle-Blind MethodSirolimusTime FactorsTreatment OutcomeUnited StatesConceptsPaclitaxel-eluting stentsMajor adverse cardiac eventsTwo-year clinical outcomesTAXUS paclitaxel-eluting stentSPIRIT III trialXience V EESAdverse cardiac eventsMyocardial infarction rateUpper normal levelCreatine kinase-MBSide branchesLower ratesThinner stent strutsPeriprocedural increasePeriprocedural myonecrosisPES patientsEES groupIII trialsInfarction rateCardiac eventsSide branch compromiseCardiac deathPES groupClinical outcomesAdverse outcomesA pooled gender based analysis comparing the XIENCE V(R) everolimus-eluting stent and the TAXUS paclitaxel-eluting stent in male and female patients with coronary artery disease, results of the SPIRIT II and SPIRIT III studies: two-year analysis.
Seth A, Serruys PW, Lansky A, Hermiller J, Onuma Y, Miquel-Hebert K, Yu S, Veldhof S, Sood P, Sudhir K, Stone GW. A pooled gender based analysis comparing the XIENCE V(R) everolimus-eluting stent and the TAXUS paclitaxel-eluting stent in male and female patients with coronary artery disease, results of the SPIRIT II and SPIRIT III studies: two-year analysis. EuroIntervention 2010, 5: 788-94. PMID: 20142192, DOI: 10.4244/eijv5i7a132.Peer-Reviewed Original ResearchMeSH KeywordsAgedAngioplasty, Balloon, CoronaryCardiovascular AgentsCoronary AngiographyCoronary RestenosisCoronary StenosisDrug-Eluting StentsEverolimusFemaleHumansKaplan-Meier EstimateMaleMiddle AgedMulticenter Studies as TopicMyocardial InfarctionPaclitaxelProsthesis DesignRandomized Controlled Trials as TopicRetrospective StudiesRisk AssessmentRisk FactorsSex FactorsSingle-Blind MethodSirolimusThrombosisTime FactorsTreatment OutcomeConceptsMajor adverse cardiac eventsPaclitaxel-eluting stentsTAXUS paclitaxel-eluting stentTarget vessel failureAngiographic late lossLate lossDiameter stenosisIII studyPooled analysisSPIRIT IIAdverse cardiac eventsSegment late lossStent late lossCoronary artery diseaseEES groupCardiac eventsArtery diseaseFemale patientsPES groupPatient levelClinical dataXIENCE VStent typeTwo-year analysisWomen
2009
Clinical and angiographic outcomes with an everolimus‐eluting stent in large coronary arteries: The SPIRIT III 4.0 mm registry
Gordon PC, Applegate RJ, Hermiller JB, Weinsier SB, Doostzadeh J, Cao S, Sudhir K, Lansky AJ, Stone GW. Clinical and angiographic outcomes with an everolimus‐eluting stent in large coronary arteries: The SPIRIT III 4.0 mm registry. Catheterization And Cardiovascular Interventions 2009, 75: 179-186. PMID: 19877267, DOI: 10.1002/ccd.22259.Peer-Reviewed Original ResearchMeSH KeywordsAgedAngioplasty, Balloon, CoronaryCardiovascular AgentsCoronary AngiographyCoronary StenosisDrug-Eluting StentsEverolimusFemaleHumansKaplan-Meier EstimateMaleMiddle AgedMyocardial InfarctionPaclitaxelPredictive Value of TestsProspective StudiesRegistriesRisk AssessmentSingle-Blind MethodSirolimusThrombosisTime FactorsTreatment OutcomeUnited StatesConceptsMajor adverse cardiac eventsTarget vessel failureSegment late lossSPIRIT III trialLarge coronary arteriesPaclitaxel-eluting stentsLate lossCoronary arteryIII trialsXIENCE VDe novo native coronary artery lesionsNovo native coronary artery lesionsNative coronary artery lesionsPE armSPIRIT IIIAdverse cardiac eventsCoronary artery lesionsAdverse clinical eventsAngiographic late lossEES patientsNoninferior ratesPrimary endpointAngiographic outcomesArtery lesionsCardiac eventsGender‐based evaluation of the XIENCE V™ everolimus‐eluting coronary stent system:
Lansky AJ, Ng VG, Mutlu H, Cristea E, Guiran JB, Midei M, Newman W, Sanz M, Sood P, Doostzadeh J, Su X, White R, Cao S, Sudhir K, Stone GW. Gender‐based evaluation of the XIENCE V™ everolimus‐eluting coronary stent system:. Catheterization And Cardiovascular Interventions 2009, 74: 719-727. PMID: 19530147, DOI: 10.1002/ccd.22067.Peer-Reviewed Original ResearchMeSH KeywordsAgedAngioplasty, Balloon, CoronaryCardiovascular AgentsCardiovascular DiseasesCoronary AngiographyCoronary Artery DiseaseCoronary RestenosisDrug-Eluting StentsEverolimusFemaleHumansKaplan-Meier EstimateLinear ModelsLogistic ModelsMaleMiddle AgedMyocardial InfarctionPaclitaxelProspective StudiesProsthesis DesignRisk AssessmentRisk FactorsSex FactorsSingle-Blind MethodSirolimusThrombosisTime FactorsTreatment OutcomeWomen's HealthConceptsSPIRIT III trialIII trialsXIENCE VTaxus stentXience V stentTVF rateTAXUS paclitaxel-eluting stentRate of MACECoronary artery lesionsStent thrombosis ratesPercutaneous coronary interventionStent late lossPaclitaxel-eluting stentsCoronary stent systemHigher MACEMore hypertensionAngiographic characteristicsArtery lesionsCoronary interventionThrombosis rateAngiographic resultsClinical outcomesClinical benefitStent placementSubset analysis
2007
Nonrandomized Comparison of Coronary Stenting Under Intravascular Ultrasound Guidance of Direct Stenting Without Predilation Versus Conventional Predilation With a Semi-Compliant Balloon Versus Predilation With a New Scoring Balloon
de Ribamar Costa J, Mintz GS, Carlier SG, Mehran R, Teirstein P, Sano K, Liu X, Lui J, Na Y, Castellanos C, Biro S, Dani L, Rinker J, Moussa I, Dangas G, Lansky AJ, Kreps EM, Collins M, Stone GW, Moses JW, Leon MB. Nonrandomized Comparison of Coronary Stenting Under Intravascular Ultrasound Guidance of Direct Stenting Without Predilation Versus Conventional Predilation With a Semi-Compliant Balloon Versus Predilation With a New Scoring Balloon. The American Journal Of Cardiology 2007, 100: 812-817. PMID: 17719325, DOI: 10.1016/j.amjcard.2007.03.100.Peer-Reviewed Original ResearchConceptsIntravascular ultrasound guidanceMinimum stent areaStent expansionDirect stentingStent areaUltrasound guidanceStent diameterConsecutive de novo lesionsFinal minimum stent areaDrug-eluting stent eraDe novo lesionsReference vessel sizeSemi-compliant balloonMinimum stent diameterNovo lesionsCoronary stentingStent eraNonrandomized studyNonrandomized comparisonLesion preparationFinal stent expansionScoring balloonPredilationLesion morphologyDES expansionPercutaneous Coronary Revascularization Using a Trilayer Metal Phosphorylcholine-Coated Zotarolimus-Eluting Stent
Abizaid A, Lansky AJ, Fitzgerald PJ, Tanajura LF, Feres F, Staico R, Mattos L, Abizaid A, Chaves A, Centemero M, Sousa AG, Sousa JE, Zaugg MJ, Schwartz LB. Percutaneous Coronary Revascularization Using a Trilayer Metal Phosphorylcholine-Coated Zotarolimus-Eluting Stent. The American Journal Of Cardiology 2007, 99: 1403-1408. PMID: 17493469, DOI: 10.1016/j.amjcard.2006.12.064.Peer-Reviewed Original ResearchMeSH KeywordsAgedAngioplasty, Balloon, CoronaryBlood Vessel Prosthesis ImplantationCardiovascular AgentsCoronary AngiographyCoronary CirculationCoronary RestenosisCoronary StenosisFemaleFollow-Up StudiesHumansMaleMiddle AgedPhosphorylcholineProspective StudiesProsthesis DesignResearch DesignSirolimusStentsTreatment OutcomeTunica IntimaUltrasonography, InterventionalConceptsCoronary artery stenosisQuantitative coronary angiographyZoMaxx stentCoronary angiographyArtery stenosisDe novo coronary artery stenosisSingle-arm prospective clinical trialDevice-deployment success ratesMajor adverse cardiac eventsSegment late lumen lossCoronary occlusive diseaseIntravascular ultrasound resultsNeointimal volume obstructionAdverse cardiac eventsIndependent core laboratoryLate lumen lossNative coronary arteriesPercutaneous coronary revascularizationProspective clinical trialsCoronary stent systemReduction of restenosisCoronary revascularizationVolume obstructionCardiac eventsObstructive lesions