2021
Differential impact of abluminal groove‐filled biodegradable‐polymer sirolimus‐eluting stent versus durable‐polymer everolimus‐eluting stent on and off dual antiplatelet therapy
Saito Y, Wijns W, Baumbach A, Xu B, Kelbæk H, Zheng M, Morel M, Anderson R, Schächinger V, Lansky A, Investigators T. Differential impact of abluminal groove‐filled biodegradable‐polymer sirolimus‐eluting stent versus durable‐polymer everolimus‐eluting stent on and off dual antiplatelet therapy. Catheterization And Cardiovascular Interventions 2021, 99: 357-365. PMID: 33502809, DOI: 10.1002/ccd.29468.Peer-Reviewed Original ResearchConceptsDual antiplatelet therapyTarget lesion failureDrug-eluting stentsTarget vessel myocardial infarctionBiodegradable polymer drug-eluting stentsChronic coronary syndromeAcute coronary syndromeDAPT discontinuationVessel myocardial infarctionAntiplatelet therapyCoronary syndromeMyocardial infarctionDurable polymer drug-eluting stentsIschemia-driven target lesion revascularizationIschemic coronary artery diseaseTarget lesion revascularizationIschemia-driven revascularizationPercutaneous coronary interventionCoronary artery diseaseIschemic coronary diseaseComer studyLesion revascularizationDAPT durationLesion failurePrimary endpoint
2018
Targeted therapy with a localised abluminal groove, low-dose sirolimus-eluting, biodegradable polymer coronary stent (TARGET All Comers): a multicentre, open-label, randomised non-inferiority trial
Lansky A, Wijns W, Xu B, Kelbæk H, van Royen N, Zheng M, Morel MA, Knaapen P, Slagboom T, Johnson TW, Vlachojannis G, Arkenbout KE, Holmvang L, Janssens L, Ochala A, Brugaletta S, Naber CK, Anderson R, Rittger H, Berti S, Barbato E, Toth GG, Maillard L, Valina C, Buszman P, Thiele H, Schächinger V, Baumbach A, Investigators T. Targeted therapy with a localised abluminal groove, low-dose sirolimus-eluting, biodegradable polymer coronary stent (TARGET All Comers): a multicentre, open-label, randomised non-inferiority trial. The Lancet 2018, 392: 1117-1126. PMID: 30190206, DOI: 10.1016/s0140-6736(18)31649-0.Peer-Reviewed Original ResearchConceptsLate lumen lossStent late lumen lossTarget lesion failureCoronary artery diseaseNon-inferiority trialXience groupPrimary endpointLesion failureLumen lossAbluminal grooveAngiographic substudyComers populationArtery diseaseMyocardial ischaemiaMyocardial infarctionIschaemia-driven target lesion revascularisationAsymptomatic coronary artery diseaseTarget vessel myocardial infarctionIschemic coronary artery diseaseST-elevation myocardial infarctionRandom block allocationTarget lesion revascularisationStent thrombosis ratesVessel myocardial infarctionElevation myocardial infarction
2002
New-Device Angioplasty in Women: Clinical Outcome and Predictors in a 7,372-Patient Registry
Lansky AJ, Mehran R, Dangas G, Desai K, Costantini-Ortiz C, Cristea E, New G, Negoita M, Stone GW, Leon MB. New-Device Angioplasty in Women: Clinical Outcome and Predictors in a 7,372-Patient Registry. Epidemiology 2002, 13: s46-s51. PMID: 12071484, DOI: 10.1097/00001648-200205001-00010.Peer-Reviewed Original ResearchConceptsMajor adverse cardiac eventsNew device angioplastyClinical outcomesFemale genderHospital mortalityLate mortalityIndependent predictorsMortality rateHospital major adverse cardiac eventsIschemic coronary artery diseaseLong-term clinical outcomesSaphenous vein graft lesionsMultivariable logistic regression analysisDevice-specific outcomesHospital cardiac mortalityLate clinical outcomesAdverse cardiac eventsComorbid risk factorsCongestive heart failureNative coronary arteriesOutcomes of womenVein graft lesionsCoronary artery diseaseReference vessel sizeConventional balloon angioplasty