2019
Evaluation of 11C-LSN3172176 as a Novel PET Tracer for Imaging M1 Muscarinic Acetylcholine Receptors in Nonhuman Primates
Nabulsi NB, Holden D, Zheng MQ, Bois F, Lin SF, Najafzadeh S, Gao H, Ropchan J, Lara-Jaime T, Labaree D, Shirali A, Slieker L, Jesudason C, Barth V, Navarro A, Kant N, Carson RE, Huang Y. Evaluation of 11C-LSN3172176 as a Novel PET Tracer for Imaging M1 Muscarinic Acetylcholine Receptors in Nonhuman Primates. Journal Of Nuclear Medicine 2019, 60: 1147-1153. PMID: 30733324, DOI: 10.2967/jnumed.118.222034.Peer-Reviewed Original ResearchConceptsMuscarinic acetylcholine receptorsAcetylcholine receptorsNonhuman primatesM1 muscarinic acetylcholine receptorBrain time-activity curvesRich brain regionsArterial blood samplingNovel PET tracersSuitable reference regionRegional distribution volumesReference regionDevelopment of drugsBrain uptakeGlobus pallidusDistribution volume valuesNucleus accumbensBlood samplingPET scansTime-activity curvesCognitive impairmentAlzheimer's diseaseBrain regionsDistribution volumeSelective radiotracerRhesus monkeys
2017
PET imaging of α7 nicotinic acetylcholine receptors: a comparative study of [18F]ASEM and [18F]DBT-10 in nonhuman primates, and further evaluation of [18F]ASEM in humans
Hillmer AT, Li S, Zheng MQ, Scheunemann M, Lin SF, Nabulsi N, Holden D, Pracitto R, Labaree D, Ropchan J, Teodoro R, Deuther-Conrad W, Esterlis I, Cosgrove KP, Brust P, Carson RE, Huang Y. PET imaging of α7 nicotinic acetylcholine receptors: a comparative study of [18F]ASEM and [18F]DBT-10 in nonhuman primates, and further evaluation of [18F]ASEM in humans. European Journal Of Nuclear Medicine And Molecular Imaging 2017, 44: 1042-1050. PMID: 28120003, PMCID: PMC5400702, DOI: 10.1007/s00259-017-3621-8.Peer-Reviewed Original Research
2014
Evaluation of the sensitivity of the novel α4β2* nicotinic acetylcholine receptor PET radioligand 18F‐(‐)‐NCFHEB to increases in synaptic acetylcholine levels in rhesus monkeys
Gallezot J, Esterlis I, Bois F, Zheng M, Lin S, Kloczynski T, Krystal JH, Huang Y, Sabri O, Carson RE, Cosgrove KP. Evaluation of the sensitivity of the novel α4β2* nicotinic acetylcholine receptor PET radioligand 18F‐(‐)‐NCFHEB to increases in synaptic acetylcholine levels in rhesus monkeys. Synapse 2014, 68: 556-564. PMID: 25043426, PMCID: PMC4224280, DOI: 10.1002/syn.21767.Peer-Reviewed Original ResearchConceptsSynaptic acetylcholine concentrationPositron emission tomographyAcetylcholine concentrationRhesus monkeysInfusion of physostigmineSynaptic acetylcholine levelsDose-dependent reductionNicotinic acetylcholine receptorsAcetylcholine levelsBolus injectionAcetylcholine receptorsAcetylcholine dynamicsNew radioligandEmission tomographyArterial input functionAcetylcholinesterase inhibitorsRadioligandThalamusPhysostigmineDonepezilΑ4β2Promising tracerBaselineMonkeysShort scan duration