2019
Direct List Mode Parametric Reconstruction for Dynamic Cardiac SPECT
Shi L, Lu Y, Wu J, Gallezot JD, Boutagy N, Thorn S, Sinusas AJ, Carson RE, Liu C. Direct List Mode Parametric Reconstruction for Dynamic Cardiac SPECT. IEEE Transactions On Medical Imaging 2019, 39: 119-128. PMID: 31180845, PMCID: PMC7030971, DOI: 10.1109/tmi.2019.2921969.Peer-Reviewed Original ResearchConceptsAppropriate kinetic modelConventional indirect methodImage reconstruction algorithmKinetic modelHigh noise levelsLow count levelsVivo canine studyIndirect methodImage noiseNoise levelParametric reconstructionNoiseReconstruction algorithmFrame imagePatient radiation dose reductionMethodDirect methodLower image noise
2016
T1-refBlochi: high resolution 3D post-contrast T1 myocardial mapping based on a single 3D late gadolinium enhancement volume, Bloch equations, and a reference T1
Hu C, Sinusas AJ, Huber S, Thorn S, Stacy MR, Mojibian H, Peters DC. T1-refBlochi: high resolution 3D post-contrast T1 myocardial mapping based on a single 3D late gadolinium enhancement volume, Bloch equations, and a reference T1. Journal Of Cardiovascular Magnetic Resonance 2016, 19: 63. PMID: 28821300, PMCID: PMC5563030, DOI: 10.1186/s12968-017-0375-1.Peer-Reviewed Original ResearchAlgorithmsAnimalsCardiomyopathiesComputer SimulationContrast MediaFeasibility StudiesFemaleFibrosisHeart AtriaHumansImage Interpretation, Computer-AssistedImaging, Three-DimensionalMagnetic Resonance ImagingMaleMiddle AgedModels, CardiovascularMonte Carlo MethodOrganometallic CompoundsPhantoms, ImagingPredictive Value of TestsReproducibility of ResultsSus scrofaQuantitative Analysis of Dynamic 123I-mIBG SPECT Imaging Data in Healthy Humans with a Population-Based Metabolite Correction Method
Wu J, Lin SF, Gallezot JD, Chan C, Prasad R, Thorn S, Stacy MR, Huang Y, Zonouz TH, Liu YH, Lampert RJ, Carson RE, Sinusas AJ, Liu C. Quantitative Analysis of Dynamic 123I-mIBG SPECT Imaging Data in Healthy Humans with a Population-Based Metabolite Correction Method. Journal Of Nuclear Medicine 2016, 57: 1226-1232. PMID: 27081169, DOI: 10.2967/jnumed.115.171710.Peer-Reviewed Original Research3-IodobenzylguanidineAdultAgedAlgorithmsArtifactsComputer SimulationFemaleHeartHumansImage EnhancementImage Interpretation, Computer-AssistedMaleMiddle AgedModels, CardiovascularModels, StatisticalMyocardiumRadiopharmaceuticalsReproducibility of ResultsSensitivity and SpecificityTissue DistributionTomography, Emission-Computed, Single-Photon
2012
A three-dimensional model-based partial volume correction strategy for gated cardiac mouse PET imaging
Dumouchel T, Thorn S, Kordos M, DaSilva J, Beanlands RS, deKemp RA. A three-dimensional model-based partial volume correction strategy for gated cardiac mouse PET imaging. Physics In Medicine And Biology 2012, 57: 4309-4334. PMID: 22705820, DOI: 10.1088/0031-9155/57/13/4309.Peer-Reviewed Original Research