2019
Direct List Mode Parametric Reconstruction for Dynamic Cardiac SPECT
Shi L, Lu Y, Wu J, Gallezot JD, Boutagy N, Thorn S, Sinusas AJ, Carson RE, Liu C. Direct List Mode Parametric Reconstruction for Dynamic Cardiac SPECT. IEEE Transactions On Medical Imaging 2019, 39: 119-128. PMID: 31180845, PMCID: PMC7030971, DOI: 10.1109/tmi.2019.2921969.Peer-Reviewed Original ResearchConceptsAppropriate kinetic modelConventional indirect methodImage reconstruction algorithmKinetic modelHigh noise levelsLow count levelsVivo canine studyIndirect methodImage noiseNoise levelParametric reconstructionNoiseReconstruction algorithmFrame imagePatient radiation dose reductionMethodDirect methodLower image noise
2016
T1-refBlochi: high resolution 3D post-contrast T1 myocardial mapping based on a single 3D late gadolinium enhancement volume, Bloch equations, and a reference T1
Hu C, Sinusas AJ, Huber S, Thorn S, Stacy MR, Mojibian H, Peters DC. T1-refBlochi: high resolution 3D post-contrast T1 myocardial mapping based on a single 3D late gadolinium enhancement volume, Bloch equations, and a reference T1. Journal Of Cardiovascular Magnetic Resonance 2016, 19: 63. PMID: 28821300, PMCID: PMC5563030, DOI: 10.1186/s12968-017-0375-1.Peer-Reviewed Original ResearchAlgorithmsAnimalsCardiomyopathiesComputer SimulationContrast MediaFeasibility StudiesFemaleFibrosisHeart AtriaHumansImage Interpretation, Computer-AssistedImaging, Three-DimensionalMagnetic Resonance ImagingMaleMiddle AgedModels, CardiovascularMonte Carlo MethodOrganometallic CompoundsPhantoms, ImagingPredictive Value of TestsReproducibility of ResultsSus scrofaQuantitative Analysis of Dynamic 123I-mIBG SPECT Imaging Data in Healthy Humans with a Population-Based Metabolite Correction Method
Wu J, Lin SF, Gallezot JD, Chan C, Prasad R, Thorn S, Stacy MR, Huang Y, Zonouz TH, Liu YH, Lampert RJ, Carson RE, Sinusas AJ, Liu C. Quantitative Analysis of Dynamic 123I-mIBG SPECT Imaging Data in Healthy Humans with a Population-Based Metabolite Correction Method. Journal Of Nuclear Medicine 2016, 57: 1226-1232. PMID: 27081169, DOI: 10.2967/jnumed.115.171710.Peer-Reviewed Original Research3-IodobenzylguanidineAdultAgedAlgorithmsArtifactsComputer SimulationFemaleHeartHumansImage EnhancementImage Interpretation, Computer-AssistedMaleMiddle AgedModels, CardiovascularModels, StatisticalMyocardiumRadiopharmaceuticalsReproducibility of ResultsSensitivity and SpecificityTissue DistributionTomography, Emission-Computed, Single-Photon
2015
Scatter and crosstalk corrections for 99mTc/123I dual‐radionuclide imaging using a CZT SPECT system with pinhole collimators
Fan P, Hutton BF, Holstensson M, Ljungberg M, Pretorius P, Prasad R, Ma T, Liu Y, Wang S, Thorn SL, Stacy MR, Sinusas AJ, Liu C. Scatter and crosstalk corrections for 99mTc/123I dual‐radionuclide imaging using a CZT SPECT system with pinhole collimators. Medical Physics 2015, 42: 6895-6911. PMID: 26632046, DOI: 10.1118/1.4934830.Peer-Reviewed Original ResearchConceptsDual-radionuclide imagingCrosstalk correction methodTEW methodLine source experimentDefect contrastSource experimentsMonte Carlo simulationsIncomplete charge collectionCadmium zinc telluride detectorsLow-energy tailImaging systemCarlo simulationsPinhole collimatorCardiac SPECT systemEnergy tailDetector effectsEnergy spectrumPoint source measurementsSPECT systemCZT detectorsTriple energy window (TEW) methodScatter modelDedicated cardiac SPECT systemsCorrection methodCrosstalk correction
2010
Kinetic model‐based factor analysis of dynamic sequences for 82‐rubidium cardiac positron emission tomography
Klein R, Beanlands RS, Wassenaar RW, Thorn SL, Lamoureux M, DaSilva JN, Adler A, deKemp RA. Kinetic model‐based factor analysis of dynamic sequences for 82‐rubidium cardiac positron emission tomography. Medical Physics 2010, 37: 3995-4010. PMID: 20879561, DOI: 10.1118/1.3438474.Peer-Reviewed Original Research