2025
Common arrhythmias and their management in the adolescent with congenital heart disease
Beach C, Vinocur J. Common arrhythmias and their management in the adolescent with congenital heart disease. Current Opinion In Pediatrics 2025, 37: 433-440. PMID: 40831345, DOI: 10.1097/mop.0000000000001491.Peer-Reviewed Original ResearchConceptsCongenital heart diseaseTranscatheter pulmonary valve replacementRisk of ventricular tachycardiaHeart diseasePulmonary valve replacementPacing-induced cardiomyopathyPacemaker lead placementLong-term riskCardiac dyssynchronyValve replacementCatheter ablationCongenital anomaliesInfrequent complicationLead placementAdolescent patientsVentricular tachycardiaDevice implantationLong-term benefitsArrhythmiasSuccess rateTachyarrhythmiasPatientsRiskDiseaseAdolescents
2024
PATCH (Preferred Attachment Strategy for Optimal Electrocardiograms)-1 Study
Becker R, Harnett B, Wayne D, Mardis R, Meganathan K, Steen D. PATCH (Preferred Attachment Strategy for Optimal Electrocardiograms)-1 Study. Clinical Research In Cardiology 2024, 114: 497-506. PMID: 39527276, DOI: 10.1007/s00392-024-02572-6.Peer-Reviewed Original ResearchStable cardiovascular diseaseAmbulatory clinic visitsAmbulatory clinic settingCardiovascular diseaseS-ECGClinical research coordinatorsClinical indicationsClinic visitsResearch coordinatorsValvular heart diseaseCoronary artery diseaseMedical practiceParticipantsEssential hypertensionClinical settingLead placementAtrial fibrillationHeart diseaseHeart failureTreatment decisionsArtery diseaseST-TElectrocardiographyBaselineHeart rhythm
2023
Responsive neurostimulation as a treatment for super-refractory focal status epilepticus: a systematic review and case series.
Ernst L, Raslan A, Wabulya A, Shin H, Cash S, Yang J, Sagi V, King-Stephens D, Damisah E, Ramos A, Hussain B, Toprani S, Brandman D, Shahlaie K, Kanth K, Arain A, Peters A, Rolston J, Berns M, Patel S, Uysal U. Responsive neurostimulation as a treatment for super-refractory focal status epilepticus: a systematic review and case series. Journal Of Neurosurgery 2023, 140: 201-209. PMID: 37329518, DOI: 10.3171/2023.4.jns23367.Peer-Reviewed Original ResearchConceptsSuper-refractory status epilepticusStatus epilepticusCase seriesTreatment optionsCase reportCollection formFocal status epilepticusRetrospective chart reviewSignificant adverse eventsEffective treatment optionResponsive neurostimulation systemUnique clinical scenarioData collection formOptimal stimulation settingsFocal SEAdverse eventsChart reviewLead placementEligibility criteriaResponsive neurostimulationTenth caseTotal casesIRB approvalStimulation settingsClinical scenarios
2020
Mapping of subthalamic nucleus using microelectrode recordings during deep brain stimulation
Koirala N, Serrano L, Paschen S, Falk D, Anwar A, Kuravi P, Deuschl G, Groppa S, Muthuraman M. Mapping of subthalamic nucleus using microelectrode recordings during deep brain stimulation. Scientific Reports 2020, 10: 19241. PMID: 33159098, PMCID: PMC7648837, DOI: 10.1038/s41598-020-74196-5.Peer-Reviewed Original ResearchConceptsMicroelectrode recordingsBackground activityStereotactic magnetic resonance imagingLow beta frequency rangeDeep brain stimulation surgeryBilateral STN-DBSSide effect ratioDeep brain stimulationBeta frequency rangeMagnetic resonance imagingSTN-DBSAwake patientsLead placementSubthalamic nucleusIntraoperative decisionAnatomical sitesBrain stimulationDBS electrodesOptimal target localizationResonance imagingMaximum spike rateBeta rangeSpike ratePatientsImplantation
2019
Association of body mass index with cardiac resynchronization therapy intention and left ventricular lead implantation failure: insights from the NCDR implantable cardioverter-defibrillator registry
Nishimura M, Marcus GM, Varosy PD, Bao H, Wang Y, Curtis JP, Hsu JC. Association of body mass index with cardiac resynchronization therapy intention and left ventricular lead implantation failure: insights from the NCDR implantable cardioverter-defibrillator registry. Journal Of Interventional Cardiac Electrophysiology 2019, 57: 279-288. PMID: 31004224, DOI: 10.1007/s10840-019-00550-x.Peer-Reviewed Original ResearchConceptsBody mass indexLV lead placementLead placementImplantation failureMass indexExtreme obesityBody habitusHigher oddsNational Cardiovascular Data Registry ICD RegistryImplantable Cardioverter-Defibrillator RegistrySuccessful LV lead placementPatient body mass indexWorld Health Organization classificationBackgroundCardiac resynchronization therapyNormal weight patientsVentricular lead placementCRT-D therapyPatient body habitusHierarchical logistic regressionEligible patientsWeight patientsMultivariable adjustmentClinical characteristicsDefibrillator implantationBiventricular pacing
2017
Coronary Venous Dissection from Left Ventricular Lead Placement During Cardiac Resynchronization Therapy With Defibrillator Implantation and Associated in-Hospital Adverse Events (from the NCDR ICD Registry)
Hsu JC, Varosy PD, Bao H, Dewland TA, Curtis JP, Marcus GM. Coronary Venous Dissection from Left Ventricular Lead Placement During Cardiac Resynchronization Therapy With Defibrillator Implantation and Associated in-Hospital Adverse Events (from the NCDR ICD Registry). The American Journal Of Cardiology 2017, 121: 55-61. PMID: 29102348, DOI: 10.1016/j.amjcard.2017.09.019.Peer-Reviewed Original ResearchConceptsCRT-D recipientsVentricular lead placementHospital adverse eventsVenous dissectionMultivariable adjustmentAdverse eventsMajor complicationsLead placementGreater oddsPrevious coronary artery bypass graftImplantable Cardioverter-Defibrillator RegistryLeft ventricular lead placementCoronary artery bypass graftHierarchical multivariable logistic regressionHospital clinical outcomesArtery bypass graftCardiac resynchronization therapyMultivariable logistic regressionBundle branch blockHospital complicationsHospital mortalityHospital deathHospital stayDefibrillator implantationProlonged hospitalization
2013
CARDIAC PERFORATION FROM IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR LEAD PLACEMENT AND IN-HOSPITAL ADVERSE EVENTS AND MORTALITY: INSIGHTS FROM THE NCDR®
Hsu J, Varosy P, Bao H, Dewland T, Curtis J, Marcus G. CARDIAC PERFORATION FROM IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR LEAD PLACEMENT AND IN-HOSPITAL ADVERSE EVENTS AND MORTALITY: INSIGHTS FROM THE NCDR®. Journal Of The American College Of Cardiology 2013, 61: e249. DOI: 10.1016/s0735-1097(13)60249-1.Peer-Reviewed Original Research
2007
Coronary magnetic resonance vein imaging: Imaging contrast, sequence, and timing
Nezafat R, Han Y, Peters DC, Herzka DA, Wylie JV, Goddu B, Kissinger KK, Yeon SB, Zimetbaum PJ, Manning WJ. Coronary magnetic resonance vein imaging: Imaging contrast, sequence, and timing. Magnetic Resonance In Medicine 2007, 58: 1196-1206. PMID: 17969081, DOI: 10.1002/mrm.21395.Peer-Reviewed Original ResearchConceptsCardiac resynchronization therapyCoronary vein anatomyCongestive heart failureCoronary veinVein anatomyCardiovascular MRCoronary sinus leadCoronary venous anatomyTransvenous lead placementInterventional cardiovascular proceduresResynchronization therapyDevice therapyHeart failureVenous anatomyLead placementEpicardial leadsCardiovascular proceduresLeft ventricleCHF subjectsCMR techniquesVivo studiesLateral wallVeinTherapyCardiac cycle
This site is protected by hCaptcha and its Privacy Policy and Terms of Service apply