2024
Noninvasive quantification of [18F]SynVesT-1 binding using simplified reference tissue model 2
Naganawa M, Gallezot J, Li S, Nabulsi N, Henry S, Cai Z, Matuskey D, Huang Y, Carson R. Noninvasive quantification of [18F]SynVesT-1 binding using simplified reference tissue model 2. European Journal Of Nuclear Medicine And Molecular Imaging 2024, 1-9. PMID: 39155309, DOI: 10.1007/s00259-024-06885-6.Peer-Reviewed Original ResearchPositron emission tomographyCentrum semiovaleReference regionPositron emission tomography scanTest-retest variabilityTest-retest reproducibilitySynaptic vesicle glycoprotein 2AOne-tissue compartmentArterial blood samplesRetest scansGold standardBrain uptakeEmission tomographyBlood samplesCerebellumNoninvasive quantificationSRTM2ConclusionOur findingsPopulation averageHealthy participantsMetabolite analysisScan timeBPNDSemiovale
2021
Imaging Pituitary Vasopressin 1B Receptor in Humans with the PET Radiotracer 11C-TASP699
Naganawa M, Nabulsi NB, Matuskey D, Henry S, Ropchan J, Lin SF, Gao H, Pracitto R, Labaree D, Zhang MR, Suhara T, Nishino I, Sabia H, Ozaki S, Huang Y, Carson RE. Imaging Pituitary Vasopressin 1B Receptor in Humans with the PET Radiotracer 11C-TASP699. Journal Of Nuclear Medicine 2021, 63: 609-614. PMID: 34385336, DOI: 10.2967/jnumed.121.262430.Peer-Reviewed Original ResearchConceptsMultilinear analysis 1Test-retest variabilityPlasma concentrationsHealthy subjectsR occupancyR antagonistBrain regionsMetabolite-corrected arterial input functionAbsolute test-retest variabilityAdrenal axis activityNovel PET radiotracersSubstantial specific bindingDose-dependent fashionVasopressin 1b receptorTest-retest reproducibilityHalf maximal inhibitory concentrationAdverse eventsAxis activityOutcome measuresReceptor occupancyTime-activity curvesArginine vasopressinPosterior pituitaryDistribution volumeNeuropsychiatric disordersAssessment of test-retest reproducibility of [18F]SynVesT-1, a novel radiotracer for PET imaging of synaptic vesicle glycoprotein 2A
Li S, Naganawa M, Pracitto R, Najafzadeh S, Holden D, Henry S, Matuskey D, Emery PR, Cai Z, Ropchan J, Nabulsi N, Carson RE, Huang Y. Assessment of test-retest reproducibility of [18F]SynVesT-1, a novel radiotracer for PET imaging of synaptic vesicle glycoprotein 2A. European Journal Of Nuclear Medicine And Molecular Imaging 2021, 48: 1327-1338. PMID: 33416954, DOI: 10.1007/s00259-020-05149-3.Peer-Reviewed Original ResearchConceptsTest-retest reproducibilityTime-activity curvesBPND valuesNonhuman primatesAbsolute test-retest variabilitySynaptic vesicle glycoprotein 2AHigh brain uptakeNon-displaceable binding potentialExcellent test-retest reproducibilityGray matter areasHealthy human subjectsHigh uptakeTest-retest variabilityDynamic PET scanningTest-retest reliabilityBrain uptakeDistribution volume valuesCentrum semiovaleUrinary bladderOne-tissue compartment modelMaximum SUVPET scanningPET scansTracer uptakeBrain disorders
2020
First-in-Human Assessment of 11C-LSN3172176, an M1 Muscarinic Acetylcholine Receptor PET Radiotracer
Naganawa M, Nabulsi N, Henry S, Matuskey D, Lin SF, Slieker L, Schwarz AJ, Kant N, Jesudason C, Ruley K, Navarro A, Gao H, Ropchan J, Labaree D, Carson RE, Huang Y. First-in-Human Assessment of 11C-LSN3172176, an M1 Muscarinic Acetylcholine Receptor PET Radiotracer. Journal Of Nuclear Medicine 2020, 62: 553-560. PMID: 32859711, PMCID: PMC8049371, DOI: 10.2967/jnumed.120.246967.Peer-Reviewed Original ResearchConceptsSimplified reference tissue modelM1 receptorsHealthy subjectsMuscarinic acetylcholine receptor subtype M1Distribution volumePET radiotracersAbsolute test-retest variabilityExcellent test-retest reproducibilityReference tissue model 2Total distribution volumeSuitable reference regionTest-retest reproducibilityTest-retest variabilityReference regionTest-retest protocolNondisplaceable distribution volumeReference tissue modelTest-retest studySubtypes M1Preclinical studiesRegional time-activity curvesAcetylcholine concentrationHuman studiesReceptor occupancyTime-activity curvesKinetic Modeling and Test–Retest Reproducibility of 11C-EKAP and 11C-FEKAP, Novel Agonist Radiotracers for PET Imaging of the κ-Opioid Receptor in Humans
Naganawa M, Li S, Nabulsi N, Lin SF, Labaree D, Ropchan J, Gao H, Mei M, Henry S, Matuskey D, Carson RE, Huang Y. Kinetic Modeling and Test–Retest Reproducibility of 11C-EKAP and 11C-FEKAP, Novel Agonist Radiotracers for PET Imaging of the κ-Opioid Receptor in Humans. Journal Of Nuclear Medicine 2020, 61: 1636-1642. PMID: 32169917, PMCID: PMC9364890, DOI: 10.2967/jnumed.119.227694.Peer-Reviewed Original ResearchConceptsTest-retest reproducibilityΚ-opioid receptorsRegional time-activity curvesTest-retest variabilityTime-activity curves
2019
Imaging the Enzyme 11β-Hydroxysteroid Dehydrogenase Type 1 with PET: Evaluation of the Novel Radiotracer 11C-AS2471907 in Human Brain
Gallezot JD, Nabulsi N, Henry S, Pracitto R, Planeta B, Ropchan J, Lin SF, Labaree D, Kapinos M, Shirali A, Lara-Jaime T, Gao H, Matuskey D, Walzer M, Marek GJ, Bellaire S, Yuan N, Carson RE, Huang Y. Imaging the Enzyme 11β-Hydroxysteroid Dehydrogenase Type 1 with PET: Evaluation of the Novel Radiotracer 11C-AS2471907 in Human Brain. Journal Of Nuclear Medicine 2019, 60: 1140-1146. PMID: 30877174, DOI: 10.2967/jnumed.118.219766.Peer-Reviewed Original ResearchConceptsTest-retest variabilityNondisplaceable distribution volumeOccipital cortexEnzyme 11β-hydroxysteroid dehydrogenase type 1White matterDistribution volumeTreatment of depressionDehydrogenase type 1Large cortical regionsPosttraumatic stress disorderHuman brainAdditional scansIntraclass correlation coefficientAge-related cognitive functionBolus administrationFrontal cortexCaudate nucleusAdipose tissueTime-activity curvesNovel radiotracersGlucocorticoid levelsParietal cortexCortical regionsPattern of uptakeType 1