2020
Preclinical Validation of a Single-Scan Rest/Stress Imaging Technique for 13N-Ammonia Positron Emission Tomography Cardiac Perfusion Studies
Guehl N, Pelletier-Galarneau M, Wooten D, Guerrero J, Kas A, Normandin M, Fakhri G, Alpert N. Preclinical Validation of a Single-Scan Rest/Stress Imaging Technique for 13N-Ammonia Positron Emission Tomography Cardiac Perfusion Studies. Circulation Cardiovascular Imaging 2020, 13: e009407. PMID: 31959009, PMCID: PMC7205554, DOI: 10.1161/circimaging.119.009407.Peer-Reviewed Original ResearchConceptsMyocardial blood flowPerfusion imagingMyocardial perfusion imaging proceduresSCAN-ALeft anterior descending arteryDose of adenosineAbsolute myocardial blood flowStress perfusion imagingAnterior descending arteryCardiac perfusion studiesMyocardial blood flow measurementsBland-Altman analysisNonstationary kinetic modelPositron emission tomographyMeasurement of restMyocardial blood flow valuesPharmacological stressorDescending arteryPreclinical validationMyocardial blood flow estimatesSingle-scan acquisitionPerfusion studiesVariable dosesImaging sessionMicrosphere MBF measurements
2019
Autoradiography validation of novel tau PET tracer [F-18]-MK-6240 on human postmortem brain tissue
Aguero C, Dhaynaut M, Normandin M, Amaral A, Guehl N, Neelamegam R, Marquie M, Johnson K, El Fakhri G, Frosch M, Gomez-Isla T. Autoradiography validation of novel tau PET tracer [F-18]-MK-6240 on human postmortem brain tissue. Acta Neuropathologica Communications 2019, 7: 37. PMID: 30857558, PMCID: PMC6410510, DOI: 10.1186/s40478-019-0686-6.Peer-Reviewed Original ResearchConceptsIn vivo detection of neurofibrillary tanglesNeurofibrillary tanglesDetection of neurofibrillary tanglesAlzheimer's diseaseTDP-43Binds to neurofibrillary tanglesFrontotemporal lobar degeneration-tauOff-target bindingDNA-binding protein 43Binding patternsNon-Alzheimer tauopathiesHuman postmortem brain tissueTau aggregationPostmortem brain tissueBinding signalBinding targetsCerebral amyloid angiopathyIn vivo detectionB-amyloidNeurodegenerative diseasesHuman brain tissueTauTau positron emission tomographyBindingMK-6240
2016
Pharmacokinetic Evaluation of the Tau PET Radiotracer 18F-T807 (18F-AV-1451) in Human Subjects
Wooten D, Guehl N, Verwer E, Shoup T, Yokell D, Zubcevik N, Vasdev N, Zafonte R, Johnson K, Fakhri G, Normandin M. Pharmacokinetic Evaluation of the Tau PET Radiotracer 18F-T807 (18F-AV-1451) in Human Subjects. Journal Of Nuclear Medicine 2016, 58: 484-491. PMID: 27660144, PMCID: PMC5334185, DOI: 10.2967/jnumed.115.170910.Peer-Reviewed Original ResearchConceptsDistribution volume ratioTraumatic brain injuryMetabolite-corrected arterial input functionPET imagingPlasma radioactivity concentrationsTemporal cortexDynamic PET imagesTotal volume of distributionVolume of distributionTraumatic brain injury subjectsMesial temporal cortexArterial blood samplesPosterior cingulate gyrusFocal uptakeSUV ratioHuman subjectsArterial input functionPosterior corpus callosumBolus injectionPharmacokinetic evaluation