2024
Validation of a Simplified Tissue-to-Reference Ratio Measurement Using SUVR to Assess Synaptic Density Alterations in Alzheimer Disease with [11C]UCB-J PET
Young J, O’Dell R, Naganawa M, Toyonaga T, Chen M, Nabulsi N, Huang Y, Cooper E, Miller A, Lam J, Bates K, Ruan A, Nelsen K, Salardini E, Carson R, van Dyck C, Mecca A. Validation of a Simplified Tissue-to-Reference Ratio Measurement Using SUVR to Assess Synaptic Density Alterations in Alzheimer Disease with [11C]UCB-J PET. Journal Of Nuclear Medicine 2024, 65: jnumed.124.267419. PMID: 39299782, PMCID: PMC11533916, DOI: 10.2967/jnumed.124.267419.Peer-Reviewed Original ResearchDistribution volume ratioSUV ratioSynaptic densityEffect sizeAlzheimer's diseaseLongitudinal study of Alzheimer's diseaseMethods:</b> ParticipantsLongitudinal studyMeasure synaptic densityAD participantsStudy of Alzheimer's diseaseNormal cognitionReference regionOlder adultsMulticenterDensity alterationsNoninvasive quantification of [18F]SynVesT-1 binding using simplified reference tissue model 2
Naganawa M, Gallezot J, Li S, Nabulsi N, Henry S, Cai Z, Matuskey D, Huang Y, Carson R. Noninvasive quantification of [18F]SynVesT-1 binding using simplified reference tissue model 2. European Journal Of Nuclear Medicine And Molecular Imaging 2024, 1-9. PMID: 39155309, DOI: 10.1007/s00259-024-06885-6.Peer-Reviewed Original ResearchPositron emission tomographyCentrum semiovaleReference regionPositron emission tomography scanTest-retest variabilityTest-retest reproducibilitySynaptic vesicle glycoprotein 2AOne-tissue compartmentArterial blood samplesRetest scansGold standardBrain uptakeEmission tomographyBlood samplesCerebellumNoninvasive quantificationSRTM2ConclusionOur findingsPopulation averageHealthy participantsMetabolite analysisScan timeBPNDSemiovale
2020
First-in-Human Assessment of 11C-LSN3172176, an M1 Muscarinic Acetylcholine Receptor PET Radiotracer
Naganawa M, Nabulsi N, Henry S, Matuskey D, Lin SF, Slieker L, Schwarz AJ, Kant N, Jesudason C, Ruley K, Navarro A, Gao H, Ropchan J, Labaree D, Carson RE, Huang Y. First-in-Human Assessment of 11C-LSN3172176, an M1 Muscarinic Acetylcholine Receptor PET Radiotracer. Journal Of Nuclear Medicine 2020, 62: 553-560. PMID: 32859711, PMCID: PMC8049371, DOI: 10.2967/jnumed.120.246967.Peer-Reviewed Original ResearchConceptsSimplified reference tissue modelM1 receptorsHealthy subjectsMuscarinic acetylcholine receptor subtype M1Distribution volumePET radiotracersAbsolute test-retest variabilityExcellent test-retest reproducibilityReference tissue model 2Total distribution volumeSuitable reference regionTest-retest reproducibilityTest-retest variabilityReference regionTest-retest protocolNondisplaceable distribution volumeReference tissue modelTest-retest studySubtypes M1Preclinical studiesRegional time-activity curvesAcetylcholine concentrationHuman studiesReceptor occupancyTime-activity curvesFirst-in-Human Evaluation of 18F-SynVesT-1, a Radioligand for PET Imaging of Synaptic Vesicle Glycoprotein 2A
Naganawa M, Li S, Nabulsi N, Henry S, Zheng MQ, Pracitto R, Cai Z, Gao H, Kapinos M, Labaree D, Matuskey D, Huang Y, Carson RE. First-in-Human Evaluation of 18F-SynVesT-1, a Radioligand for PET Imaging of Synaptic Vesicle Glycoprotein 2A. Journal Of Nuclear Medicine 2020, 62: 561-567. PMID: 32859701, PMCID: PMC8049363, DOI: 10.2967/jnumed.120.249144.Peer-Reviewed Original ResearchConceptsC-UCBSynaptic densityRegional time-activity curvesTime-activity curvesDistribution volumeMetabolite-corrected arterial input functionPET imagingMultilinear analysis 1Synaptic vesicle glycoprotein 2AAntiepileptic drug levetiracetamTotal distribution volumeNondisplaceable distribution volumeCentrum semiovaleBlocking doseHealthy volunteersHuman studiesDrug levetiracetamLassen plotNeuropsychiatric disordersPET radioligandArterial input functionNonhuman primatesLevetiracetamReference regionRadioligand
2019
Assessment of a white matter reference region for 11C-UCB-J PET quantification
Rossano S, Toyonaga T, Finnema SJ, Naganawa M, Lu Y, Nabulsi N, Ropchan J, De Bruyn S, Otoul C, Stockis A, Nicolas JM, Martin P, Mercier J, Huang Y, Maguire RP, Carson RE. Assessment of a white matter reference region for 11C-UCB-J PET quantification. Cerebrovascular And Brain Metabolism Reviews 2019, 40: 1890-1901. PMID: 31570041, PMCID: PMC7446568, DOI: 10.1177/0271678x19879230.Peer-Reviewed Original ResearchEvaluation of 11C-LSN3172176 as a Novel PET Tracer for Imaging M1 Muscarinic Acetylcholine Receptors in Nonhuman Primates
Nabulsi NB, Holden D, Zheng MQ, Bois F, Lin SF, Najafzadeh S, Gao H, Ropchan J, Lara-Jaime T, Labaree D, Shirali A, Slieker L, Jesudason C, Barth V, Navarro A, Kant N, Carson RE, Huang Y. Evaluation of 11C-LSN3172176 as a Novel PET Tracer for Imaging M1 Muscarinic Acetylcholine Receptors in Nonhuman Primates. Journal Of Nuclear Medicine 2019, 60: 1147-1153. PMID: 30733324, DOI: 10.2967/jnumed.118.222034.Peer-Reviewed Original ResearchConceptsMuscarinic acetylcholine receptorsAcetylcholine receptorsNonhuman primatesM1 muscarinic acetylcholine receptorBrain time-activity curvesRich brain regionsArterial blood samplingNovel PET tracersSuitable reference regionRegional distribution volumesReference regionDevelopment of drugsBrain uptakeGlobus pallidusDistribution volume valuesNucleus accumbensBlood samplingPET scansTime-activity curvesCognitive impairmentAlzheimer's diseaseBrain regionsDistribution volumeSelective radiotracerRhesus monkeys
2018
2181 Age-related change in 5-HT6 receptor availability in healthy male volunteers measured with 11C-GSK215083 PET
Radhakrishnan R, Nabulsi N, Gaiser E, Gallezot J, Henry S, Planeta B, Lin S, Ropchan J, Williams W, Morris E, D’Souza D, Huang Y, Carson R, Matuskey D. 2181 Age-related change in 5-HT6 receptor availability in healthy male volunteers measured with 11C-GSK215083 PET. Journal Of Clinical And Translational Science 2018, 2: 3-4. PMCID: PMC6799074, DOI: 10.1017/cts.2018.44.Peer-Reviewed Original ResearchReceptor availabilityEffect of ageHealthy male volunteersSerotonin receptor 6Healthy male subjectsPotential therapeutic targetSignificant age-related declineMultilinear analysis-1 (MA1) methodAge-related changesAge-related declineMale volunteersTherapeutic targetNegative correlationTime-activity curvesReceptor 6PET ligandMale subjectsBrain regionsCortical regionsVentral striatumAgePutamenStriatumCaudateReference region
2017
Evaluation of (‐)‐[18F]Flubatine‐specific binding: Implications for reference region approaches
Bhatt S, Hillmer AT, Nabulsi N, Matuskey D, Lim K, Lin S, Esterlis I, Carson RE, Huang Y, Cosgrove KP. Evaluation of (‐)‐[18F]Flubatine‐specific binding: Implications for reference region approaches. Synapse 2017, 72 PMID: 29105121, PMCID: PMC6547815, DOI: 10.1002/syn.22016.Peer-Reviewed Original ResearchConceptsNicotinic acetylcholine receptorsPositron emission tomographyCorpus callosumAcetylcholine receptorsGreater receptor occupancyReference regionRegion-based quantificationMin bolusTobacco smokersFrontal cortexTobacco cigarettesReceptor occupancyConstant infusionDistribution volumeEmission tomographyCallosumSpecific bindingBrainReceptorsSmokersSmokingPutamenInfusionBolusCortex
2015
Test–Retest Reproducibility of Binding Parameters in Humans with 11C-LY2795050, an Antagonist PET Radiotracer for the κ Opioid Receptor
Naganawa M, Zheng MQ, Henry S, Nabulsi N, Lin SF, Ropchan J, Labaree D, Najafzadeh S, Kapinos M, Tauscher J, Neumeister A, Carson RE, Huang Y. Test–Retest Reproducibility of Binding Parameters in Humans with 11C-LY2795050, an Antagonist PET Radiotracer for the κ Opioid Receptor. Journal Of Nuclear Medicine 2015, 56: 243-248. PMID: 25593119, PMCID: PMC4322754, DOI: 10.2967/jnumed.114.147975.Peer-Reviewed Original ResearchConceptsTest-retest variabilityOpioid receptorsOutcome measuresAbsolute test-retest variabilityMultilinear analysis 1Healthy human subjectsSuitable reference regionTest-retest reproducibilityIntraclass correlation coefficientAntagonist radiotracersHealthy subjectsLY2795050PET scansBrain regionsDistribution volumePET radioligandTest-retest performancePET studiesArterial input functionPET radiotracersHuman subjectsReference regionReceptorsVT valuesKOR
2013
Studies of the metabotropic glutamate receptor 5 radioligand [11C]ABP688 with N‐acetylcysteine challenge in rhesus monkeys
Sandiego CM, Nabulsi N, Lin S, Labaree D, Najafzadeh S, Huang Y, Cosgrove K, Carson RE. Studies of the metabotropic glutamate receptor 5 radioligand [11C]ABP688 with N‐acetylcysteine challenge in rhesus monkeys. Synapse 2013, 67: 489-501. PMID: 23424090, PMCID: PMC3710146, DOI: 10.1002/syn.21656.Peer-Reviewed Original ResearchConceptsN-acetylcysteineRhesus monkeysCerebellum gray matterMetabotropic glutamate receptor 5N-acetylcysteine challengeBaboon studiesGlutamate receptor 5Non-displaceable binding potentialHigh intersubject variabilityReference regionRecent pilot studySignificant global decreaseGlutamate transmissionNAC doseEndogenous glutamatePsychiatric illnessReceptor 5Gray matterAllosteric antagonistsPilot studyReceptor bindingIntersubject variabilitySame dayDoseMonkeys
2010
Evaluation of [11C]MRB for assessment of occupancy of norepinephrine transporters: Studies with atomoxetine in non-human primates
Gallezot JD, Weinzimmer D, Nabulsi N, Lin SF, Fowles K, Sandiego C, McCarthy TJ, Maguire RP, Carson RE, Ding YS. Evaluation of [11C]MRB for assessment of occupancy of norepinephrine transporters: Studies with atomoxetine in non-human primates. NeuroImage 2010, 56: 268-279. PMID: 20869448, PMCID: PMC3710586, DOI: 10.1016/j.neuroimage.2010.09.040.Peer-Reviewed Original ResearchConceptsAttention deficit hyperactivity disorderPositron emission tomographyNorepinephrine transporterDrug occupancy studiesRhesus monkeysReference regionTreatment of depressionDose-dependent reductionVolume of distributionArterial blood samplingSuitable reference regionOccupancy studiesNon-human primatesBrain norepinephrine transportersPromising radioligandPlasma levelsTherapeutic doseOccipital cortexBlood samplingUptake inhibitorAtomoxetineEmission tomographyEffective dosePET studiesArterial input function