2021
PET Imaging Estimates of Regional Acetylcholine Concentration Variation in Living Human Brain
Smart K, Naganawa M, Baldassarri SR, Nabulsi N, Ropchan J, Najafzadeh S, Gao H, Navarro A, Barth V, Esterlis I, Cosgrove KP, Huang Y, Carson RE, Hillmer AT. PET Imaging Estimates of Regional Acetylcholine Concentration Variation in Living Human Brain. Cerebral Cortex 2021, 31: 2787-2798. PMID: 33442731, PMCID: PMC8355478, DOI: 10.1093/cercor/bhaa387.Peer-Reviewed Original ResearchConceptsACh concentrationHuman volunteersHigh ACh concentrationsMuscarinic antagonist scopolamineHealthy human volunteersHuman brainCholinergic receptorsNicotine challengeAntagonist scopolaminePreclinical studiesStriatal regionsPET scansEndogenous neurotransmittersNeuropsychiatric diseasesNonhuman primatesWhole-brain imagesDrug occupancyNicotinic ligandsClinical populationsBrainAcetylcholineDistinct functional rolesStriatumVolunteersFunctional roleAssessment of test-retest reproducibility of [18F]SynVesT-1, a novel radiotracer for PET imaging of synaptic vesicle glycoprotein 2A
Li S, Naganawa M, Pracitto R, Najafzadeh S, Holden D, Henry S, Matuskey D, Emery PR, Cai Z, Ropchan J, Nabulsi N, Carson RE, Huang Y. Assessment of test-retest reproducibility of [18F]SynVesT-1, a novel radiotracer for PET imaging of synaptic vesicle glycoprotein 2A. European Journal Of Nuclear Medicine And Molecular Imaging 2021, 48: 1327-1338. PMID: 33416954, DOI: 10.1007/s00259-020-05149-3.Peer-Reviewed Original ResearchConceptsTest-retest reproducibilityTime-activity curvesBPND valuesNonhuman primatesAbsolute test-retest variabilitySynaptic vesicle glycoprotein 2AHigh brain uptakeNon-displaceable binding potentialExcellent test-retest reproducibilityGray matter areasHealthy human subjectsHigh uptakeTest-retest variabilityDynamic PET scanningTest-retest reliabilityBrain uptakeDistribution volume valuesCentrum semiovaleUrinary bladderOne-tissue compartment modelMaximum SUVPET scanningPET scansTracer uptakeBrain disorders
2020
First-in-Human Evaluation of 18F-SynVesT-1, a Radioligand for PET Imaging of Synaptic Vesicle Glycoprotein 2A
Naganawa M, Li S, Nabulsi N, Henry S, Zheng MQ, Pracitto R, Cai Z, Gao H, Kapinos M, Labaree D, Matuskey D, Huang Y, Carson RE. First-in-Human Evaluation of 18F-SynVesT-1, a Radioligand for PET Imaging of Synaptic Vesicle Glycoprotein 2A. Journal Of Nuclear Medicine 2020, 62: 561-567. PMID: 32859701, PMCID: PMC8049363, DOI: 10.2967/jnumed.120.249144.Peer-Reviewed Original ResearchConceptsC-UCBSynaptic densityRegional time-activity curvesTime-activity curvesDistribution volumeMetabolite-corrected arterial input functionPET imagingMultilinear analysis 1Synaptic vesicle glycoprotein 2AAntiepileptic drug levetiracetamTotal distribution volumeNondisplaceable distribution volumeCentrum semiovaleBlocking doseHealthy volunteersHuman studiesDrug levetiracetamLassen plotNeuropsychiatric disordersPET radioligandArterial input functionNonhuman primatesLevetiracetamReference regionRadioligand
2017
Novel 18F-Labeled κ-Opioid Receptor Antagonist as PET Radiotracer: Synthesis and In Vivo Evaluation of 18F-LY2459989 in Nonhuman Primates
Li S, Cai Z, Zheng MQ, Holden D, Naganawa M, Lin SF, Ropchan J, Labaree D, Kapinos M, Lara-Jaime T, Navarro A, Huang Y. Novel 18F-Labeled κ-Opioid Receptor Antagonist as PET Radiotracer: Synthesis and In Vivo Evaluation of 18F-LY2459989 in Nonhuman Primates. Journal Of Nuclear Medicine 2017, 59: 140-146. PMID: 28747521, PMCID: PMC5750518, DOI: 10.2967/jnumed.117.195586.Peer-Reviewed Original ResearchConceptsPET radiotracersNonhuman primatesTime-activity curvesHigh specific binding signalsΚ-opioid receptor antagonistCentral nervous system disordersFast tissue kineticsBrain time-activity curvesCaudate/putamenNervous system disordersΚ-opioid receptorsRegional binding potentialPeak uptake timeRegional distribution volumesAntagonist radiotracersReceptor antagonistFrontal cortexNovel 18FRegional time-activity curvesSystem disordersNovel radioligandPET scansSpecific binding signalsTemporal cortexMonkey brain
2016
First-in-Human Assessment of the Novel PDE2A PET Radiotracer 18F-PF-05270430
Naganawa M, Waterhouse RN, Nabulsi N, Lin SF, Labaree D, Ropchan J, Tarabar S, DeMartinis N, Ogden A, Banerjee A, Huang Y, Carson RE. First-in-Human Assessment of the Novel PDE2A PET Radiotracer 18F-PF-05270430. Journal Of Nuclear Medicine 2016, 57: 1388-1395. PMID: 27103022, PMCID: PMC5093918, DOI: 10.2967/jnumed.115.166850.Peer-Reviewed Original ResearchMeSH KeywordsAnimalsAzabicyclo CompoundsAzetidinesBrainComputer SimulationCyclic Nucleotide Phosphodiesterases, Type 2Feasibility StudiesFemaleHumansIsotope LabelingMacaca mulattaMaleMetabolic Clearance RateModels, BiologicalMolecular ImagingOrgan SpecificityPilot ProjectsPositron-Emission TomographyRadiopharmaceuticalsReproducibility of ResultsSensitivity and SpecificityTissue DistributionConceptsTest-retest variabilityHuman studiesPET ligandWhite matterNeocortical regionsMultilinear analysis 1MSv/MBqHealthy male subjectsDetectable pharmacologic effectsAppropriate tracer kinetic modelsTest-retest protocolAdverse eventsBrain uptakePharmacologic effectsRegional time-activity curvesTarget doseTime-activity curvesTracer uptakeMale subjectsWhole brainBrain regionsEffective doseCritical organsPET radiotracersNonhuman primates