2022
PET myocardial perfusion imaging in superior vena cava syndrome
Mezue K, Chow D, Tawakol A, Fakhri G, Osborne M. PET myocardial perfusion imaging in superior vena cava syndrome. Journal Of Nuclear Cardiology 2022, 30: 1720-1724. PMID: 35764777, PMCID: PMC9794631, DOI: 10.1007/s12350-022-03033-1.Peer-Reviewed Original Research
2020
Preclinical Validation of a Single-Scan Rest/Stress Imaging Technique for 13N-Ammonia Positron Emission Tomography Cardiac Perfusion Studies
Guehl N, Pelletier-Galarneau M, Wooten D, Guerrero J, Kas A, Normandin M, Fakhri G, Alpert N. Preclinical Validation of a Single-Scan Rest/Stress Imaging Technique for 13N-Ammonia Positron Emission Tomography Cardiac Perfusion Studies. Circulation Cardiovascular Imaging 2020, 13: e009407. PMID: 31959009, PMCID: PMC7205554, DOI: 10.1161/circimaging.119.009407.Peer-Reviewed Original ResearchConceptsMyocardial blood flowPerfusion imagingMyocardial perfusion imaging proceduresSCAN-ALeft anterior descending arteryDose of adenosineAbsolute myocardial blood flowStress perfusion imagingAnterior descending arteryCardiac perfusion studiesMyocardial blood flow measurementsBland-Altman analysisNonstationary kinetic modelPositron emission tomographyMeasurement of restMyocardial blood flow valuesPharmacological stressorDescending arteryPreclinical validationMyocardial blood flow estimatesSingle-scan acquisitionPerfusion studiesVariable dosesImaging sessionMicrosphere MBF measurements
2019
Quantification of PET Myocardial Blood Flow
Pelletier-Galarneau M, Martineau P, El Fakhri G. Quantification of PET Myocardial Blood Flow. Current Cardiology Reports 2019, 21: 11. PMID: 30815744, DOI: 10.1007/s11886-019-1096-x.Peer-Reviewed Original ResearchMeSH KeywordsCoronary AngiographyCoronary Artery DiseaseCoronary CirculationFractional Flow Reserve, MyocardialHumansMicrocirculationMicrovesselsMyocardial Perfusion ImagingPositron-Emission TomographyConceptsPositron emission tomographyMyocardial blood flowMyocardial flow reserveMicrovascular dysfunctionEvaluation of cardiac allograft vasculopathyAssessment of coronary microvascular dysfunctionFlow reserveHyperemic myocardial blood flowFlow quantificationCardiac allograft vasculopathyMarkers of disease severityCoronary microvascular dysfunctionImprove risk stratificationQuantification of myocardial blood flowFractional flow reserveMyocardial blood flow quantificationAllograft vasculopathyPrognostic valueRisk stratificationEpicardial diseaseAcademic centersReviewThe aimClinical aspectsEmission tomographyBlood flow
2018
Joint reconstruction of rest/stress myocardial perfusion SPECT
Lai X, Petibon Y, Fakhri G, Ouyang J. Joint reconstruction of rest/stress myocardial perfusion SPECT. Physics In Medicine And Biology 2018, 63: 135019. PMID: 29897044, PMCID: PMC6245543, DOI: 10.1088/1361-6560/aacc2f.Peer-Reviewed Original ResearchMeSH KeywordsHumansImage Processing, Computer-AssistedModels, TheoreticalMyocardial Perfusion ImagingMyocardiumPhantoms, ImagingSignal-To-Noise RatioTomography, Emission-Computed, Single-PhotonConceptsMyocardial perfusion imagingSingle photon emission computed tomographyReversible defectsSignal-to-noise ratioRest/stress SPECT myocardial perfusion imagingSPECT myocardial perfusion imagingConventional subtraction methodDefect detectionJoint methodPhoton emission computed tomographySubtraction methodReverse mappingClinical dose levelsEmission computed tomographyImprove defect detectionLow noiseNon-invasive assessmentClinical dosePerfusion defectsReduced doseImprove radiologists' performanceReconstruction frameworkRest imagesPerfusion imagingDose levels
2017
Direct parametric reconstruction in dynamic PET myocardial perfusion imaging: in vivo studies
Petibon Y, Rakvongthai Y, Fakhri G, Ouyang J. Direct parametric reconstruction in dynamic PET myocardial perfusion imaging: in vivo studies. Physics In Medicine And Biology 2017, 62: 3539-3565. PMID: 28379843, PMCID: PMC5739089, DOI: 10.1088/1361-6560/aa6394.Peer-Reviewed Original ResearchMeSH KeywordsAlgorithmsAnimalsImage Processing, Computer-AssistedMyocardial Perfusion ImagingPositron-Emission TomographyPyridazinesRadiopharmaceuticalsSignal-To-Noise RatioSwineConceptsPET sinogramsSignal-to-noise ratioList-mode PET dataSiemens Biograph mMR scannerList-mode dataMyocardial perfusion imagingNoise realizationsPET myocardial perfusion imagingLow count levelsLeast-squares fitBiograph mMR scannerPET projection dataOriginal list-mode dataMyocardial blood flowCount levelsParametric reconstructionOSEMReconstruction methodIndependent noise realizationsNormal count levelsSinogramDirect reconstructionDynamic sinogramsKinetic modelPoor signal-to-noise ratioSingle-scan rest/stress imaging: validation in a porcine model with 18F-Flurpiridaz
Guehl N, Normandin M, Wooten D, Rozen G, Sitek A, Ruskin J, Shoup T, Ptaszek L, El Fakhri G, Alpert N. Single-scan rest/stress imaging: validation in a porcine model with 18F-Flurpiridaz. European Journal Of Nuclear Medicine And Molecular Imaging 2017, 44: 1538-1546. PMID: 28365789, DOI: 10.1007/s00259-017-3684-6.Peer-Reviewed Original ResearchMeSH KeywordsAnimalsCoronary CirculationMyocardial Perfusion ImagingPyridazinesRestStress, PhysiologicalSwineConceptsMyocardial blood flowMicrosphere flow measurementsBlood flowStress myocardial blood flowSingle-scan protocolClinical applicationShort-axis viewMyocardial blood flow measurementsPET dataBlood flow changesIntroduction of adenosineHalf-life of 18FAdenosine infusionRadiotracer injectionAxis viewMyocardial segmentsHealthy pigsClinical translationPET acquisitionTwo-injectionPig modelIschemic areaPorcine modelHalf-lifeAdenosine
2016
Impact of motion and partial volume effects correction on PET myocardial perfusion imaging using simultaneous PET-MR
Petibon Y, Guehl N, Reese T, Ebrahimi B, Normandin M, Shoup T, Alpert N, Fakhri G, Ouyang J. Impact of motion and partial volume effects correction on PET myocardial perfusion imaging using simultaneous PET-MR. Physics In Medicine And Biology 2016, 62: 326-343. PMID: 27997375, PMCID: PMC5241952, DOI: 10.1088/1361-6560/aa5087.Peer-Reviewed Original ResearchMeSH KeywordsAnimalsImage Processing, Computer-AssistedMagnetic Resonance ImagingMovementMyocardial Perfusion ImagingMyocardiumPositron-Emission TomographySwineConceptsSimultaneous PET-MRPET myocardial perfusion imagingMyocardial perfusion imagingPoint spread functionPoint-spread function correctionUngated dataMotion correctionPET-MRPartial volume effectsApparent wall thicknessMyocardial blood flowPartial volume effect correctionMR-based motion correctionMotion fieldPET-MR scannersPoint spread function modelPET dataPerfusion imagingImage qualityImpact of motionDynamic myocardial perfusion imagingAttenuation mapNon-rigid registrationAbsolute myocardial blood flowUngated images
2009
Quantitative relationship between coronary calcium content and coronary flow reserve as assessed by integrated PET/CT imaging
Curillova Z, Yaman B, Dorbala S, Kwong R, Sitek A, El Fakhri G, Anagnostopoulos C, Di Carli M. Quantitative relationship between coronary calcium content and coronary flow reserve as assessed by integrated PET/CT imaging. European Journal Of Nuclear Medicine And Molecular Imaging 2009, 36: 1603-1610. PMID: 19387640, PMCID: PMC3117296, DOI: 10.1007/s00259-009-1121-1.Peer-Reviewed Original ResearchConceptsCoronary artery calcium scoreCoronary artery calciumCoronary vasodilator functionCoronary flow reserveCoronary artery diseaseHyperemic myocardial blood flowMyocardial blood flowVasodilator functionWeak inverse correlationCAC scoreCoronary artery calcium contentFlow reserveIncreasing CAC scorePer-vessel basisPer-patient basisInverse correlationBody mass indexCoronary calcium contentCoronary risk factorsCoronary vascular resistancePET/CT imagingConclusionIn patientsArtery calciumVascular resistanceMass index