2017
Magnetic Resonance–based Motion Correction for Quantitative PET in Simultaneous PET-MR Imaging
Rakvongthai Y, Fakhri G. Magnetic Resonance–based Motion Correction for Quantitative PET in Simultaneous PET-MR Imaging. PET Clinics 2017, 12: 321-327. PMID: 28576170, PMCID: PMC6452624, DOI: 10.1016/j.cpet.2017.02.004.Peer-Reviewed Original ResearchConceptsSimultaneous PET-MRQuantitative PET imagingMotion correctionSimultaneous PET-MR imagingReconstructed PET imagesMotion-corrected imagesPET-MRMotion correction strategiesPET imagingPET-MR imagingQuantitation of PET imagesPatient studiesQuantitative PETImage qualityMotionCorrectionPhantomAnatomical informationCorrection strategyMR imaging
2016
Impact of motion and partial volume effects correction on PET myocardial perfusion imaging using simultaneous PET-MR
Petibon Y, Guehl N, Reese T, Ebrahimi B, Normandin M, Shoup T, Alpert N, Fakhri G, Ouyang J. Impact of motion and partial volume effects correction on PET myocardial perfusion imaging using simultaneous PET-MR. Physics In Medicine And Biology 2016, 62: 326-343. PMID: 27997375, PMCID: PMC5241952, DOI: 10.1088/1361-6560/aa5087.Peer-Reviewed Original ResearchConceptsSimultaneous PET-MRPET myocardial perfusion imagingMyocardial perfusion imagingPoint spread functionPoint-spread function correctionUngated dataMotion correctionPET-MRPartial volume effectsApparent wall thicknessMyocardial blood flowPartial volume effect correctionMR-based motion correctionMotion fieldPET-MR scannersPoint spread function modelPET dataPerfusion imagingImage qualityImpact of motionDynamic myocardial perfusion imagingAttenuation mapNon-rigid registrationAbsolute myocardial blood flowUngated images
2015
Accelerated acquisition of tagged MRI for cardiac motion correction in simultaneous PET‐MR: Phantom and patient studies
Huang C, Petibon Y, Ouyang J, Reese T, Ahlman M, Bluemke D, El Fakhri G. Accelerated acquisition of tagged MRI for cardiac motion correction in simultaneous PET‐MR: Phantom and patient studies. Medical Physics 2015, 42: 1087-1097. PMID: 25652521, PMCID: PMC4312342, DOI: 10.1118/1.4906247.Peer-Reviewed Original ResearchConceptsPET motion correctionMotion correctionSimultaneous PET-MRTMR dataPET list-mode dataPET-MRList-mode dataCardiac motion correctionPET-MR scannersImage qualityParallel imagingAcquisition timePET imagingRespiratory motionCompressive sensingMotion fieldAttenuation correctionDefect contrastModerate acceleration factorsDegradation of image qualityTagged MRCardiac phantomLong acquisition timesPhantomAccurate motion field
2014
Relative role of motion and PSF compensation in whole‐body oncologic PET‐MR imaging
Petibon Y, Huang C, Ouyang J, Reese T, Li Q, Syrkina A, Chen Y, Fakhri G. Relative role of motion and PSF compensation in whole‐body oncologic PET‐MR imaging. Medical Physics 2014, 41: 042503. PMID: 24694156, PMCID: PMC3971824, DOI: 10.1118/1.4868458.Peer-Reviewed Original ResearchConceptsPoint spread function modelRespiratory motionPoint spread functionPET-MR scannersPencil-beam navigator echoesPET-MRMeasurement of respiratory motionPSF modelRespiratory motion correctionDetector blur effectsModel respiratory motionLung-liver interfacePatient studiesLesion contrastSimultaneous PET-MRSource of image degradationWhole-body PET imagingPET reconstruction algorithmMoving lesionsPhantom experiment resultsPET eventsContrast recoveryNavigator echoesIterative reconstruction processMotion correctionMR‐based motion correction for PET imaging using wired active MR microcoils in simultaneous PET‐MR: Phantom study
Huang C, Ackerman J, Petibon Y, Brady T, Fakhri G, Ouyang J. MR‐based motion correction for PET imaging using wired active MR microcoils in simultaneous PET‐MR: Phantom study. Medical Physics 2014, 41: 041910. PMID: 24694141, PMCID: PMC3978416, DOI: 10.1118/1.4868457.Peer-Reviewed Original ResearchConceptsMotion correctionMR-based motion correctionStatic phantom dataPET quantitative accuracyPET-MRPET-MR scannersSimultaneous PET-MRHoffman phantomList-modePositron emission tomography imagingPET reconstructionBrain positron emission tomographyIterative PET reconstructionPhantom dataPhantomQuantitative accuracyIndependent noise realizationsImage contrastNoise realizationsHead motionPET dataPositron emission tomographyStatic referenceBrain PET scansMotion artifactsTowards coronary plaque imaging using simultaneous PET-MR: a simulation study
Petibon Y, Fakhri G, Nezafat R, Johnson N, Brady T, Ouyang J. Towards coronary plaque imaging using simultaneous PET-MR: a simulation study. Physics In Medicine And Biology 2014, 59: 1203-1222. PMID: 24556608, PMCID: PMC4061607, DOI: 10.1088/0031-9155/59/5/1203.Peer-Reviewed Original ResearchMeSH KeywordsComputer SimulationCoronary AngiographyCoronary StenosisHumansImage Interpretation, Computer-AssistedImaging, Three-DimensionalMagnetic Resonance AngiographyModels, CardiovascularMultimodal ImagingPhantoms, ImagingPositron-Emission TomographyReproducibility of ResultsSensitivity and SpecificityConceptsSimultaneous PET-MRChannelized Hotelling observerAttenuation mapMotion correctionPET-MRFluorodeoxyglucose-positron emission tomography imagingRespiratory motion fieldsMotion correction methodCho SNRMotion correction techniqueAnthropomorphic phantomUncorrected reconstructionsRespiratory motionXCAT phantomCoronary plaque imagingMonte Carlo simulationsPET reconstructionXCATActivity distributionCardiac gatingNon-rigid registrationHotelling observerCarlo simulationsPlaque imagingPhantomMotion compensation for brain PET imaging using wireless MR active markers in simultaneous PET–MR: Phantom and non-human primate studies
Huang C, Ackerman J, Petibon Y, Normandin M, Brady T, Fakhri G, Ouyang J. Motion compensation for brain PET imaging using wireless MR active markers in simultaneous PET–MR: Phantom and non-human primate studies. NeuroImage 2014, 91: 129-137. PMID: 24418501, PMCID: PMC3965607, DOI: 10.1016/j.neuroimage.2013.12.061.Peer-Reviewed Original ResearchConceptsMotion correctionWireless markersList-mode reconstructionReconstructed PET imagesMotion correction techniqueObserver signal-to-noise ratioSimultaneous PET-MRMotion artifactsPET phantomPET contrastPET reconstructionBrain PET imagingPET imagingPhantomBrain PETPET-MRIndependent noise realizationsAccurate quantitative valuesHead motionNoise realizationsPET dataSignal-to-noise ratioStatic referenceBrain PET scansActivation markers
2013
Cardiac motion compensation and resolution modeling in simultaneous PET-MR: a cardiac lesion detection study
Petibon Y, Ouyang J, Zhu X, Huang C, Reese T, Chun S, Li Q, Fakhri G. Cardiac motion compensation and resolution modeling in simultaneous PET-MR: a cardiac lesion detection study. Physics In Medicine And Biology 2013, 58: 2085-2102. PMID: 23470288, PMCID: PMC3657754, DOI: 10.1088/0031-9155/58/7/2085.Peer-Reviewed Original ResearchConceptsContrast recoveryDetector point spread functionPartial volume effectsK-spaceMotion compensationB-spline registrationLesion-detection studiesCardiac motion compensationPET-MR scannersSimultaneous PET-MRPET contrastIterative reconstruction frameworkPoint spread functionMotion correctionPET countsNon-rigid B-spline registrationCardiac phantomPSF modelPET-MRMotion deblurringReconstruction frameworkSystem matrixCardiac PETSpread functionDefect detection