2024
EEG for good outcome prediction after cardiac arrest: A multicentre cohort study
Turella S, Dankiewicz J, Ben-Hamouda N, Nilsen K, Düring J, Endisch C, Engstrøm M, Flügel D, Gaspard N, Grejs A, Haenggi M, Haffey S, Imbach L, Johnsen B, Kemlink D, Leithner C, Legriel S, Lindehammar H, Mazzon G, Nielsen N, Peyre A, Stanford B, Roman-Pognuz E, Rossetti A, Schrag C, Valeriánová A, Wendel-Garcia P, Zubler F, Cronberg T, Westhall E, investigators T. EEG for good outcome prediction after cardiac arrest: A multicentre cohort study. Resuscitation 2024, 202: 110319. PMID: 39029579, DOI: 10.1016/j.resuscitation.2024.110319.Peer-Reviewed Original ResearchConceptsMalignant EEG patternsEEG reactivityReactive EEGsCardiac arrestComatose patientsEEG patternsOut-of-hospital cardiac arrest trialModified Rankin Scale scoreMulticentre cohort studyRankin Scale scoreLong-term outcomesOut-of-hospitalCardiac arrest trialsSpecificity of EEGEEG assessmentHospital stayGood outcomeMultimodal prognosticationPrognostic performanceNon-highlyPrognostic abilityCohort studyMalignant patternArrest trialsBurst suppression
2018
EEG Reactivity Evaluation Practices for Adult and Pediatric Hypoxic-Ischemic Coma Prognostication in North America
Amorim E, Gilmore EJ, Abend NS, Hahn CD, Gaspard N, Herman ST, Hirsch LJ, Lee JW, Cash SS, Westover MB. EEG Reactivity Evaluation Practices for Adult and Pediatric Hypoxic-Ischemic Coma Prognostication in North America. Journal Of Clinical Neurophysiology 2018, 35: 510-514. PMID: 30216207, PMCID: PMC6424574, DOI: 10.1097/wnp.0000000000000517.Peer-Reviewed Original ResearchConceptsCardiac arrest prognosticationAcademic hospitalCritical Care EEG Monitoring Research ConsortiumNail bed pressureLight tactile stimuliMajority of hospitalsNeurodiagnostic technologistsPercent of respondentsPediatric hospitalMultiple-choice surveyPractice patternsEEG reactivityNational guidelinesComa prognosticationHospitalProcedure modalitiesReactivity testingPrognosticationEEG amplitudeMean numberTactile stimuliResearch ConsortiumSubstantial variabilityReactivity evaluationHypothermiaS96. EEG reactivity testing practices for cardiac arrest coma prognostication in North America
Amorim E, Gaspard N, Gilmore E, Hahn C, Abend N, Herman S, Hirsch L, Lee J, Cash S, Westover M. S96. EEG reactivity testing practices for cardiac arrest coma prognostication in North America. Clinical Neurophysiology 2018, 129: e178. DOI: 10.1016/j.clinph.2018.04.456.Peer-Reviewed Original ResearchEEG reactivityReactivity testingPractice patternsCritical Care EEG Monitoring Research ConsortiumHypoxic-ischemic brain injuryNorth American academic medical centersCardiac arrest prognosticationNail bed pressureEEG technologistsUnfavorable functional outcomeAcademic medical centerAmerican academic medical centersReactivity assessmentPediatric hospitalFunctional outcomeIctal dischargesBrain injuryMultiple-choice surveyMedical CenterInter-rater agreementStimulation protocolComa prognosticationAuditory stimulationStimulation modalitiesTesting protocol
2016
Effect of stimulus type and temperature on EEG reactivity in cardiac arrest
Fantaneanu T, Tolchin B, Alvarez V, Friolet R, Avery K, Scirica B, O’Brien M, Henderson G, Lee J. Effect of stimulus type and temperature on EEG reactivity in cardiac arrest. Clinical Neurophysiology 2016, 127: 3412-3417. PMID: 27693940, DOI: 10.1016/j.clinph.2016.09.002.Peer-Reviewed Original ResearchConceptsCardiac arrest patientsNipple pressureTherapeutic hypothermiaArrest patientsDifferent stimulus modalitiesTesting modalitiesModerate agreement ratesReliable outcome predictorsAgreement rateStimulus modalityInterrater agreementCardiac arrestOutcome predictorsEEG reactivityPressure reactivityReactive backgroundBetter outcomesHypothermiaPatientsOutcome determinationNormothermiaModalitiesBackground reactivityStimulus typePrior studies
2015
Acute brain failure in severe sepsis: a prospective study in the medical intensive care unit utilizing continuous EEG monitoring
Gilmore EJ, Gaspard N, Choi HA, Cohen E, Burkart KM, Chong DH, Claassen J, Hirsch LJ. Acute brain failure in severe sepsis: a prospective study in the medical intensive care unit utilizing continuous EEG monitoring. Intensive Care Medicine 2015, 41: 686-694. PMID: 25763756, DOI: 10.1007/s00134-015-3709-1.Peer-Reviewed Original ResearchConceptsNonconvulsive seizuresSevere sepsisEEG reactivityPeriodic dischargesLate seizuresSOFA scoreAPACHE IIFunctional outcomeContinuous sedationHigh riskLower riskMedical intensive care unitLong-term cognitive outcomesPresence of sedationAPACHE II scoreGood functional outcomeNonconvulsive status epilepticusIntensive care unitContinuous EEG monitoringAcute brain failureAcademic medical centerNew epilepsyII scoreClinical seizuresMedical ICU
2006
Prognostic significance of continuous EEG monitoring in patients with poor-grade subarachnoid hemorrhage
Claassen J, Hirsch LJ, Frontera JA, Fernandez A, Schmidt M, Kapinos G, Wittman J, Connolly ES, Emerson RG, Mayer SA. Prognostic significance of continuous EEG monitoring in patients with poor-grade subarachnoid hemorrhage. Neurocritical Care 2006, 4: 103-112. PMID: 16627897, DOI: 10.1385/ncc:4:2:103.Peer-Reviewed Original ResearchConceptsModified Rankin ScalePeriodic lateralized epileptiform dischargesSubarachnoid hemorrhageHess gradePoor outcomeEEG findingsCEEG monitoringEpileptiform dischargesPoor-grade subarachnoid hemorrhageMultivariate logistic regression analysisAdmission CT scanPeriodic epileptiform dischargesLogistic regression analysisRankin ScaleIll patientsIntraventricular hemorrhageMRS 4Functional outcomeSleep architectureEEG reactivityCT scanPatientsOutcomesHemorrhageRegression analysis
This site is protected by hCaptcha and its Privacy Policy and Terms of Service apply