2019
MR-based cardiac and respiratory motion correction of PET: application to static and dynamic cardiac 18F-FDG imaging
Petibon Y, Sun T, Han P, Ma C, Fakhri G, Ouyang J. MR-based cardiac and respiratory motion correction of PET: application to static and dynamic cardiac 18F-FDG imaging. Physics In Medicine And Biology 2019, 64: 195009. PMID: 31394518, PMCID: PMC7007962, DOI: 10.1088/1361-6560/ab39c2.Peer-Reviewed Original ResearchConceptsMR-based motion correctionRespiratory motion correctionMotion correctionImproved spatial resolutionReconstructed activity concentrationCardiac PET dataSpatial resolutionCoincidence eventsMR-basedPET imagingContrast-to-noise ratioCardiac PET imagingRespiratory phasesMC dataImprove image qualityMR acquisitionQuantitative accuracyCardiac PETPET dataActivity concentrationsMyocardium wallF-FDG PETDynamics studiesImage qualityMotion artifacts
2014
Relative role of motion and PSF compensation in whole‐body oncologic PET‐MR imaging
Petibon Y, Huang C, Ouyang J, Reese T, Li Q, Syrkina A, Chen Y, Fakhri G. Relative role of motion and PSF compensation in whole‐body oncologic PET‐MR imaging. Medical Physics 2014, 41: 042503. PMID: 24694156, PMCID: PMC3971824, DOI: 10.1118/1.4868458.Peer-Reviewed Original ResearchConceptsPoint spread function modelRespiratory motionPoint spread functionPET-MR scannersPencil-beam navigator echoesPET-MRMeasurement of respiratory motionPSF modelRespiratory motion correctionDetector blur effectsModel respiratory motionLung-liver interfacePatient studiesLesion contrastSimultaneous PET-MRSource of image degradationWhole-body PET imagingPET reconstruction algorithmMoving lesionsPhantom experiment resultsPET eventsContrast recoveryNavigator echoesIterative reconstruction processMotion correction
2012
MRI-Based Nonrigid Motion Correction in Simultaneous PET/MRI
Chun Y, Reese T, Ouyang J, Guerin B, Catana C, Zhu X, Alpert N, Fakhri G. MRI-Based Nonrigid Motion Correction in Simultaneous PET/MRI. Journal Of Nuclear Medicine 2012, 53: 1284-1291. PMID: 22743250, PMCID: PMC4077320, DOI: 10.2967/jnumed.111.092353.Peer-Reviewed Original ResearchConceptsChannelized Hotelling observerMotion correctionDetection signal-to-noise ratioSignal-to-noise ratioMRI-based motion correctionRespiratory motion correctionMotion-corrected reconstructionOrdered-subsets expectation maximization algorithmNonrigid motion correctionChannelized Hotelling observer studyPET image qualityNonrigid image registration methodCoincidence dataDeformable phantomRespiratory gatingReduce radiation doseDynamic phantomImage registration methodReduced signal-to-noise ratioSimultaneous PET/MRICost of increased noiseHotelling observerPhantomAttenuation measurementsRabbit studies