Skip to Main Content

INFORMATION FOR

    Kirk Shelley, MD/PhD

    Professor Emeritus of Anesthesiology
    DownloadHi-Res Photo

    Contact Info

    Anesthesiology

    PO Box 208051, 333 Cedar Street, TMP 3

    New Haven, CT 06520-8051

    United States

    About

    Titles

    Professor Emeritus of Anesthesiology

    Biography

    Dr Kirk Shelley is boarded in Anesthesia and Internal Medicine. He obtained MD and PhD degrees (Biochemistry) from Penn State University. Dr. Shelley's current research focuses on the development of tools for the noninvasive measurement of physiologic parameters. He is also recognized for developing this technology in an "open source" manner to further scientific collaboration.

    Appointments

    Other Departments & Organizations

    Education & Training

    Resident - Anesthesiology
    Columbia Presbyterian Medical Center (1992)
    Resident - Internal Medicine
    Lenox Hill Hospital (1984)
    MD/PhD
    Pennsylvania State University, Biochemstry (1981)

    Board Certifications

    • Anesthesiology

      Certification Organization
      AB of Anesthesiology
      Original Certification Date
      1993
    • Internal Medicine

      Certification Organization
      AB of Internal Medicine
      Original Certification Date
      1985

    Research

    Overview

    The main thrust of my work has involved pulse oximetry technology. The pulse oximeter is the most commonly used clinical monitor in the healthcare system.  The photoplethysmographic (PPG) waveform is at the core of pulse oximeter technology. I have worked to expand the understanding and use of this noninvasive cardiopulmonary waveform.  Some of my most cited papers are educational and provocative in nature.  They challenge the reader to re-examine this ubiquitous wave for features beyond its primary use of oxygen saturation measurement.  These papers point out that the PPG contains information regarding the cardiovascular, pulmonary and autonomic systems. [1-4]

    1.      Shelley, K.H., Photoplethysmography: Beyond The Calculation Of Arterial Oxygen Saturation And Heart Rate. Anesth Analg, 2007. 105(6 Suppl): p. S31-6.

    2.         Shelley, K.H. and S. Shelley, Pulse Oximeter Waveform: Photoelectric Plethysmography, in Clinical Monitoring: Practical Applications for Anesthesia and Critical Care, C.L. Lake, R.L. Hines, and C.D. Blitt, Editors. 2001, W.B. Saunders Company: Philadelphia PA. p. 420-428.

    3.         Alian, A.A. and K.H. Shelley, Photoplethysmography. Best Pract Res Clin Anaesthesiol, 2014. 28(4): p. 395-406.

    4.         Alian, A.A. and K.H. Shelley, Photoplethysmography: Analysis of the pulse oximeter waveform, in Monitoring Technologies In Acute Care Environments, J.M. Ehrenfeld and M. Cannesson, Editors. 2014, Springer New York. p. 165-178.

    In the process of studying the pulse oximeter waveform (PPG) I have discovered a number of unanticipated features.  These have included the impact of peripheral venous blood on the waveform. This has allowed for the explanation of device artifact as well the calculation of new clinical parameters.  Most notably, this research is the key component of a new monitoring technique that my laboratory developed for the detection of blood loss during pediatric cases. (1-4)

    1.         Shelley KH, Dickstein M, Shulman SM. The detection of peripheral venous pulsation using the pulse oximeter as a plethysmograph. J Clin Monit 1993;9:283-7.

    2.         Shelley K, Tamai D, Jablonka D, Gesquiere M, Stout R, Silverman D. The effect of venous pulsation on the forehead pulse oximeter wave form as a possible source of error in SPo2 calculation. Anesth Analg 2005;100:743-7.

    3.         Walton ZD, Kyriacou PA, Silverman DG, Shelley KH. Measuring venous oxygenation using the photoplethysmograph waveform. J Clin Monit Comput 2010;24:295-303.

    4.         Alian AA, Atteya G, Gaal D, Golembeski T, Smith BG, Dai F, Silverman DG, Shelley K. Ventilation-Induced Modulation of Pulse Oximeter Waveforms: A Method for the Assessment of Early Changes in Intravascular Volume During Spinal Fusion Surgery in Pediatric Patients. Anesth Analg 2016;123:346-56.

    The photoplethysmographic (PPG) waveform is created by the interaction of the cardiac, pulmonary and autonomic systems.  By studying this interaction, one can gain clues as to a patient’s condition as well as ways of optimizing it via therapeutic interventions. One of the earliest observations was the impact of ventilation on the PPG waveform.  Through my research, it was discovered that both cardiac output (stroke volume) and pre-load (venous) blood are modulated.  These modulations can be identified and quantified.  Through optimization of these parameters it was found that they could be used to guide IV fluid therapy during hypovolemia. (1-4)

    1.         Shelley KH, Awad AA, Stout RG, Silverman DG. The use of joint time frequency analysis to quantify the effect of ventilation on the pulse oximeter waveform. J Clin Monit Comput 2006;20:81-7.

    2.         Shelley KH, Jablonka DH, Awad AA, Stout RG, Rezkanna H, Silverman DG. What is the best site for measuring the effect of ventilation on the pulse oximeter waveform? Anesth Analg 2006;103:372-7.

    3.         Alian AA, Galante NJ, Stachenfeld NS, Silverman DG, Shelley KH. Impact of central hypovolemia on photoplethysmographic waveform parameters in healthy volunteers part 2: frequency domain analysis. J Clin Monit Comput 2011;25:387-96.

    4.         Scully CG, Selvaraj N, Romberg FW, Wardhan R, Ryan J, Florian JP, Silverman DG, Shelley KH, Chon KH. Using time-frequency analysis of the photoplethysmographic waveform to detect the withdrawal of 900 mL of blood. Anesth Analg 2012;115:74-81.

     

    Medical Research Interests

    Ambulatory Care; Anesthesiology; Biochemistry; Cardiovascular Diseases; Cardiovascular Physiological Phenomena; Electronics, Medical; Monitoring, Intraoperative; Plethysmography

    Research at a Glance

    Yale Co-Authors

    Frequent collaborators of Kirk Shelley's published research.

    Publications

    Featured Publications

    2024

    2023

    2021

    Academic Achievements & Community Involvement

    • honor

      JS Gravenstein Award for Lifetime Achievement

    • activity

      Visiting Fellow at the Biomedical Engineering Research Group at the School of Engineering and Mathematical Sciences. Barts and The London School of Medicine, City University, London England

    • honor

      The Harvey W. Wiley Lifetime Achievement

    • activity

      Society for Technology In Anesthesia

    • honor

      Honorary Master of Arts degree

    Get In Touch

    Contacts

    Mailing Address

    Anesthesiology

    PO Box 208051, 333 Cedar Street, TMP 3

    New Haven, CT 06520-8051

    United States

    Administrative Support

    Locations

    • Yale Anesthesiology

      Academic Office

      Tompkins Memorial Pavilion

      789 Howard Avenue, Ste 3rd floor

      New Haven, CT 06519