2025
Solvent Transport in Disordered and Dynamic Membrane Pores: Implications for Reverse Osmosis and Nanofiltration Membranes
Fan H, Elimelech M. Solvent Transport in Disordered and Dynamic Membrane Pores: Implications for Reverse Osmosis and Nanofiltration Membranes. Environmental Science And Technology 2025, 59: 17922-17931. PMID: 40815600, PMCID: PMC12392456, DOI: 10.1021/acs.est.5c07128.Peer-Reviewed Original ResearchConceptsReverse osmosisNanofiltration membranesSolvent permeabilityPore sizeSolvent transportNanoporous membranesSolvent transport mechanismsLocal friction coefficientInfluence of pore connectivityMembrane poresMembrane separation technologyImpact of pore structurePressure-driven separationViscous naturePorous structure propertiesPore connectivityMembrane performanceFriction coefficientMolecular dynamics simulationsMembrane porosityPorous structurePolymeric membranesNanofiltrationPore structureSolvent molecules
2024
Revolutionizing Airborne Virus Defense: Electromagnetic MXene-Coated Air Filtration for Superior Aerosol Viral Removal
Liu F, Ma Q, Sabuj M, Yen S, Govindan D, Gao J, Zhao M, Elimelech M, Zhang W. Revolutionizing Airborne Virus Defense: Electromagnetic MXene-Coated Air Filtration for Superior Aerosol Viral Removal. ACS Applied Materials & Interfaces 2024, 16: 10148-10157. PMID: 38363186, DOI: 10.1021/acsami.3c18227.Peer-Reviewed Original ResearchConceptsLog removalNonwoven fabric filterElectromagnetic power densityLocal heatingElectromagnetic induction fieldElectromagnetic fieldCatalyst coatingFabric filterPower densityCOMSOL simulationInactivation performanceRemoval efficiencyCoating densityFiltration systemAir filtration systemMicrobial inactivationInduction fieldFilterAir filtrationCoatingSecondary pollutionAir filtersElectromagnetic irradiationElectromagnetismAlternative solution
2023
Re-Evaluating Cross-Contamination: Additional Trials on Co-Ventilation
McMahon J, Doukas D, Hanuscin C, Quale J, Eason J, Asrat H, Silverberg M, Paladino L. Re-Evaluating Cross-Contamination: Additional Trials on Co-Ventilation. Journal Of Emergency Medicine 2023, 66: e477-e482. PMID: 38433037, DOI: 10.1016/j.jemermed.2023.10.003.Peer-Reviewed Original Research
2020
Evaluating cross contamination on a shared ventilator
Doukas D, Paladino L, Hanuscin C, McMahon J, Quale J, Bhatt I, Eason J, Silverberg M. Evaluating cross contamination on a shared ventilator. Emergency Medicine Journal 2020, 38: 220-223. PMID: 33277345, DOI: 10.1136/emermed-2020-209972.Peer-Reviewed Original ResearchComment on “Aerosol Filtration Efficiency of Common Fabrics Used in Respiratory Cloth Masks”
Hancock JN, Plumley MJ, Schilling K, Sheets D, Wilen L. Comment on “Aerosol Filtration Efficiency of Common Fabrics Used in Respiratory Cloth Masks”. ACS Nano 2020, 14: 10758-10763. PMID: 32961642, DOI: 10.1021/acsnano.0c05827.Peer-Reviewed Original ResearchReducing ECG Artifact From Left Ventricular Assist Device Electromagnetic Interference
Loring Z, Sen S, Black-Maier E, Atwater BD, Russell SD, DeVore AD, Piccini JP. Reducing ECG Artifact From Left Ventricular Assist Device Electromagnetic Interference. Journal Of The American Heart Association 2020, 9: e017563. PMID: 32787630, PMCID: PMC7660795, DOI: 10.1161/jaha.120.017563.Peer-Reviewed Original ResearchConceptsHeartMate 3 LVADElectromagnetic interferenceRotational speedBandstop filterLow-pass filterHigh-frequency signal componentsImpeller rotationFrequency peakFast Fourier transformWaveform dataSignal componentsLeft ventricular assist deviceFourier transformFilterECG artifactsSignal peaksNoise artifactsDevicesSpeedVentricular assist devicePotential solutionsAssist deviceAdditional peaksInterferenceFrequencyAn accessible method for screening aerosol filtration identifies poor-performing commercial masks and respirators
Schilling K, Gentner DR, Wilen L, Medina A, Buehler C, Perez-Lorenzo LJ, Pollitt KJG, Bergemann R, Bernardo N, Peccia J, Wilczynski V, Lattanza L. An accessible method for screening aerosol filtration identifies poor-performing commercial masks and respirators. Journal Of Exposure Science & Environmental Epidemiology 2020, 31: 943-952. PMID: 32764709, PMCID: PMC7406964, DOI: 10.1038/s41370-020-0258-7.Peer-Reviewed Original Research
2014
Spectral CT Using Multiple Balanced K-Edge Filters
Rakvongthai Y, Worstell W, Fakhri G, Bian J, Lorsakul A, Ouyang J. Spectral CT Using Multiple Balanced K-Edge Filters. IEEE Transactions On Medical Imaging 2014, 34: 740-747. PMID: 25252276, PMCID: PMC4349342, DOI: 10.1109/tmi.2014.2358561.Peer-Reviewed Original ResearchConceptsK-edge filtersReconstructed attenuation coefficientsEnergy binsAttenuation coefficientMultiple energy binsX-ray sourcesX-ray tubeBack-projection reconstructionSpectral CT imagingTransmission matrixModel expectationsSinogram binsBeam hardeningComplex phantomsSpectral computed tomographyK-edgeAttenuation imagesSpectral CTCT scannerX-rayConventional detectorsBack-projectionSinogramPhantomCost-effective system design
2009
Ballistic delivery of dyes for structural and functional studies of the nervous system.
Gan WB, Grutzendler J, Wong RO, Lichtman JW. Ballistic delivery of dyes for structural and functional studies of the nervous system. Cold Spring Harbor Protocols 2009, 2009: pdb.prot5202. PMID: 20147144, PMCID: PMC2916724, DOI: 10.1101/pdb.prot5202.Peer-Reviewed Original Research
2008
Towards a novel haemoglobin-based oxygen carrier: Euro-PEG-Hb, physico-chemical properties, vasoactivity and renal filtration
Portörő I, Kocsis L, Hermán P, Caccia D, Perrella M, Ronda L, Bruno S, Bettati S, Micalella C, Mozzarelli A, Varga A, Vas M, Lowe K, Eke A. Towards a novel haemoglobin-based oxygen carrier: Euro-PEG-Hb, physico-chemical properties, vasoactivity and renal filtration. Biochimica Et Biophysica Acta 2008, 1784: 1402-1409. PMID: 18405674, DOI: 10.1016/j.bbapap.2008.03.005.Peer-Reviewed Original Research
2002
A Comparison of Two Surface Sample Collection Devices for Use in Polymerase Chain Reaction Based Detection of Pneumocystis carinii in House Dust
Maher N, Dillon HK, Awooda A, Lee JH, Vermund SH, Unnasch TR. A Comparison of Two Surface Sample Collection Devices for Use in Polymerase Chain Reaction Based Detection of Pneumocystis carinii in House Dust. Applied Occupational And Environmental Hygiene 2002, 17: 416-423. PMID: 12049431, DOI: 10.1080/10473220290035435.Peer-Reviewed Original ResearchConceptsPolymerase Chain Reaction Based DetectionDNA detectionComposite dust samplesDetection assaysBest deviceP. carinii DNAPCR protocolSample collection deviceDevicesCassette methodDust collection efficiencyCollection efficiencyCarinii DNABased DetectionDust collection deviceOptimal assayFilter cassetteCollection deviceCassettePolymerase chain reactionVacuum pumpDetectionEfficiencyChain reactionProtocol
2001
Magnetic Bead Capture Eliminates PCR Inhibitors in Samples Collected from the Airborne Environment, Permitting Detection of Pneumocystis carinii DNA
Maher N, Dillon H, Vermund S, Unnasch T. Magnetic Bead Capture Eliminates PCR Inhibitors in Samples Collected from the Airborne Environment, Permitting Detection of Pneumocystis carinii DNA. Applied And Environmental Microbiology 2001, 67: 449-452. PMID: 11133478, PMCID: PMC92598, DOI: 10.1128/aem.67.1.449-452.2001.Peer-Reviewed Original Research
1999
Filtered Versus Unfiltered Technetium Sulfur Colloid in Lymphatic Mapping: A Significant Variable in a Pig Model
Tafra L, Chua A, Ng P, Aycock D, Swanson M, Lannin D. Filtered Versus Unfiltered Technetium Sulfur Colloid in Lymphatic Mapping: A Significant Variable in a Pig Model. Annals Of Surgical Oncology 1999, 6: 83-87. PMID: 10030419, DOI: 10.1007/s10434-999-0083-7.Peer-Reviewed Original ResearchConceptsUnfiltered groupLymphatic mappingSentinel nodesSkin sitesUnfiltered technetium sulfur colloidMore sentinel nodesSentinel node dissectionLymph node basinSentinel node biopsyFiltered groupIntraoperative lymphatic mappingTechnetium sulfur colloidSoft tissue tumorsStandard diagnostic testTc-99Node basinNode dissectionIsosulfan blueNode biopsyPreoperative lymphoscintigraphyLymph nodesSulfur colloidTissue tumorsGamma probeInjection site
1998
Chemotaxis Assays for Eukaryotic Cells
Zigmond S, Foxman E, Segall J. Chemotaxis Assays for Eukaryotic Cells. Current Protocols In Cell Biology 1998, 00: 12.1.1-12.1.29. PMID: 18228315, DOI: 10.1002/0471143030.cb1201s00.Peer-Reviewed Original Research
1996
Protocol for preparation of high concentrations of morphine.
Pascale V, Saberski L. Protocol for preparation of high concentrations of morphine. Regional Anesthesia & Pain Medicine 1996, 21: 492. PMID: 8896020, DOI: 10.1136/rapm-00115550-199621050-00023.Peer-Reviewed Original Research
1995
Biotinylation and assessment of membrane polarity: caveats and methodological concerns
Gottardi CJ, Dunbar LA, Caplan MJ. Biotinylation and assessment of membrane polarity: caveats and methodological concerns. American Journal Of Physiology 1995, 268: f285-f295. PMID: 7864168, DOI: 10.1152/ajprenal.1995.268.2.f285.Peer-Reviewed Original Research
1994
Nitric oxide synthase: An endogenous source of elevated nitrite in infected urine
Smith S, Wheeler M, Weiss R. Nitric oxide synthase: An endogenous source of elevated nitrite in infected urine. Kidney International 1994, 45: 586-591. PMID: 7513034, DOI: 10.1038/ki.1994.76.Peer-Reviewed Original ResearchConceptsUrinary tract infectionNon-infected urineTract infectionsL-arginineUrine nitriteInfected urineUrinary nitric oxide synthase activityNitric oxide synthase activityUrinary nitrite levelsEndogenous sourcesOxide synthase activitySynthase activityMin/Exogenous L-arginineNG-nitroNG-monomethylGriess methodParticulate fractionNitrite levelsUrine fractionsEndogenous productionNitrite productionUrineInfectionElevated nitrite
1992
Isolation and characterization of rabbit cardiac endothelial cells: Response to cyclic strain and growth factors in vitro
Widmann M, Letsou G, Phan S, Baldwin J, Sumpio B. Isolation and characterization of rabbit cardiac endothelial cells: Response to cyclic strain and growth factors in vitro. Journal Of Surgical Research 1992, 53: 331-334. PMID: 1405613, DOI: 10.1016/0022-4804(92)90057-7.Peer-Reviewed Original ResearchConceptsRetina-derived growth factorCardiac endothelial cellsEndothelial cellsGrowth factorPure endothelial cellsEC proliferationProliferative responseExogenous growth factorsTrophic effectsRabbit heartsAcetylated LDLCardiac endotheliumCollagenase digestionFetal bovine serumPulsatile strainSignificant increaseBovine serumProliferationEC morphologyCellsRegimenResponseLDLEndotheliumFactorsPlatelet dense granule release reaction monitored by high-performance liquid chromatography-fluorometric determination of endogenous serotonin
Anderson G, Hall L, Yang J, Cohen D. Platelet dense granule release reaction monitored by high-performance liquid chromatography-fluorometric determination of endogenous serotonin. Analytical Biochemistry 1992, 206: 64-67. PMID: 1456443, DOI: 10.1016/s0003-2697(05)80011-9.Peer-Reviewed Original Research
1991
Rate-limiting steps in Na translocation by the Na/K pump.
Forbush B, Klodos I. Rate-limiting steps in Na translocation by the Na/K pump. 1991, 46: 210-25. PMID: 1653981.Peer-Reviewed Original Research
This site is protected by hCaptcha and its Privacy Policy and Terms of Service apply