2013
Simultaneous 99mTc‐MDP/123I‐MIBG tumor imaging using SPECT‐CT: Phantom and constructed patient studies
Rakvongthai Y, Fakhri G, Lim R, Bonab A, Ouyang J. Simultaneous 99mTc‐MDP/123I‐MIBG tumor imaging using SPECT‐CT: Phantom and constructed patient studies. Medical Physics 2013, 40: 102506. PMID: 24089927, PMCID: PMC3785531, DOI: 10.1118/1.4820977.Peer-Reviewed Original ResearchConceptsScatter correctionDual-radionuclideContrast recoveryPhantom studyAnthropomorphic torso phantomPatient studiesTumor uptakeTumor imagingSPECT projectionsTorso phantomMonte-CarloPhantom dataPhantomIterative reconstructionOSEMProjection dataDR dataIncrease patient throughputNoise realizationsSPECT-CTImage reconstructionClinical studiesTumorTumor projectionPoisson noise
2009
Quantitative simultaneous cardiac SPECT using MC‐JOSEM
Ouyang J, Zhu X, Trott C, Fakhri G. Quantitative simultaneous cardiac SPECT using MC‐JOSEM. Medical Physics 2009, 36: 602-611. PMID: 19292000, PMCID: PMC2673670, DOI: 10.1118/1.3063544.Peer-Reviewed Original ResearchConceptsMC-JOSEMEnergy windowWater-filled torso phantomScatter correctionPhotopeak energy windowStandard OSEMCardiac SPECT imagingActivity concentration ratioIterative reconstruction algorithmReconstruction algorithmMyocardium wallTorso phantomActivity estimationDetector responseEmission energyBackground compartmentPhantom dataCardiac SPECTActivity distributionRest/stress imagingScatteringCases of patientsOSEMChest painCardiac protocols
2008
Improved activity estimation with MC‐JOSEM versus TEW‐JOSEM in SPECT
Ouyang J, Fakhri G, Moore S. Improved activity estimation with MC‐JOSEM versus TEW‐JOSEM in SPECT. Medical Physics 2008, 35: 2029-2040. PMID: 18561679, PMCID: PMC2673642, DOI: 10.1118/1.2907561.Peer-Reviewed Original ResearchMeSH KeywordsAlgorithmsEquipment DesignImage Processing, Computer-AssistedIndium RadioisotopesLungModels, StatisticalMonte Carlo MethodPhantoms, ImagingRadiotherapy Planning, Computer-AssistedReproducibility of ResultsScattering, RadiationSoftwareTomography, Emission-Computed, Single-PhotonTomography, X-Ray ComputedConceptsMC-JOSEMWater-filled torso phantomMC scatter estimationTriple-energy-windowActivity estimationIterative reconstruction algorithmTorso phantomPhantom studyBackground compartmentScatter estimationActivity distributionAverage relative biasPhantomReconstruction algorithmActivity concentrationsSynthetic projectionsSphere locationScattering
2006
Monte Carlo-based compensation for patient scatter, detector scatter, and crosstalk contamination in In-111 SPECT imaging
Moore S, Ouyang J, Park M, Fakhri G. Monte Carlo-based compensation for patient scatter, detector scatter, and crosstalk contamination in In-111 SPECT imaging. Nuclear Instruments And Methods In Physics Research Section A Accelerators Spectrometers Detectors And Associated Equipment 2006, 569: 472-476. DOI: 10.1016/j.nima.2006.08.079.Peer-Reviewed Original ResearchScatter projectionsPatient scatterDetector scatterOrgan activity estimatesPhoton interaction pointIterative reconstruction algorithmDetector effectsEnergy binsReconstruction algorithmDelta scatteringTorso phantomPoint spread functionSegmented CT scanInteraction pointOSEM reconstructionNumerical phantomDetectorScatteringScattering mapSpherical tumorSpread functionImage noisePhantomActivity concentrationsActivity estimation