2004
High-dose 7-hexanoyltaxol-eluting stent with polymer sleeves for coronary revascularizationOne-year results from the SCORE randomized trial
GRUBE E, LANSKY A, HAUPTMANN K, DIMARIO C, DISCIASCIO G, COLOMBO A, SILBER S, STUMPF J, REIFART N, FAJADET J. High-dose 7-hexanoyltaxol-eluting stent with polymer sleeves for coronary revascularizationOne-year results from the SCORE randomized trial. Journal Of The American College Of Cardiology 2004, 44: 1368-1372. DOI: 10.1016/s0735-1097(04)01351-8.Peer-Reviewed Original ResearchConceptsRestenosis rateStent thrombosisMajor adverse cardiac event ratesAdverse cardiac event ratesDe novo coronary lesionsTarget vessel revascularization rateEnd pointNon-Q-wave MIAngiographic restenosis rateCardiac event rateNovo coronary lesionsPrimary end pointUnacceptable safety profileVessel revascularization rateMyocardial infarction rateOpen-label trialStent thrombosis ratesClinical end pointsOne-year resultsQuantitative coronary angiographyCoronary revascularizationRevascularization ratesInfarction rateCardiac deathCoronary angiographyHigh-dose 7-hexanoyltaxol-eluting stent with polymer sleeves for coronary revascularization One-year results from the SCORE randomized trial
Grube E, Lansky A, Hauptmann K, Di Mario C, Di Sciascio G, Colombo A, Silber S, Stumpf J, Reifart N, Fajadet J, Marzocchi A, Schofer J, Dumas P, Hoffmann R, Guagliumi G, Pitney M, Russell M. High-dose 7-hexanoyltaxol-eluting stent with polymer sleeves for coronary revascularization One-year results from the SCORE randomized trial. Journal Of The American College Of Cardiology 2004, 44: 1368-1372. PMID: 15464315, DOI: 10.1016/j.jacc.2004.06.054.Peer-Reviewed Original ResearchConceptsRestenosis rateStent thrombosisMajor adverse cardiac event ratesAdverse cardiac event ratesDe novo coronary lesionsTarget vessel revascularization rateEnd pointNon-Q-wave MIAngiographic restenosis rateCardiac event rateNovo coronary lesionsPrimary end pointUnacceptable safety profileVessel revascularization rateMyocardial infarction rateOpen-label trialStent thrombosis ratesClinical end pointsOne-year resultsQuantitative coronary angiographyCoronary revascularizationRevascularization ratesInfarction rateCardiac deathCoronary angiography
2003
Safety and efficacy of a novel device for treatment of thrombotic and atherosclerotic lesions in native coronary arteries and saphenous vein grafts: Results from the multicenter X‐sizer for treatment of thrombus and atherosclerosis in coronary applications trial (X‐TRACT) study
Stone GW, Cox DA, Low R, Cates CU, Satler L, Bailey SR, Kuntz RE, Lansky AJ. Safety and efficacy of a novel device for treatment of thrombotic and atherosclerotic lesions in native coronary arteries and saphenous vein grafts: Results from the multicenter X‐sizer for treatment of thrombus and atherosclerosis in coronary applications trial (X‐TRACT) study. Catheterization And Cardiovascular Interventions 2003, 58: 419-427. PMID: 12652487, DOI: 10.1002/ccd.10511.Peer-Reviewed Original ResearchMeSH KeywordsAgedAngioplasty, Balloon, CoronaryAtherectomy, CoronaryChi-Square DistributionCoronary AngiographyCoronary Artery DiseaseCoronary ThrombosisEquipment DesignEquipment SafetyFemaleFollow-Up StudiesGraft Occlusion, VascularHumansMaleMiddle AgedProbabilityRisk AssessmentSaphenous VeinStatistics, NonparametricStentsThrombectomyTreatment OutcomeConceptsSaphenous vein graftsNative coronary arteriesVein graftsX-SizerThrombotic lesionsCoronary arteryNon-Q-wave MIDistal branch occlusionTIMI 3 flowSide branch occlusionTreatment of thrombusDistal thromboemboliPeriprocedural MITIMI 0Adverse eventsThromboembolic complicationsConsecutive patientsAntegrade flowBranch occlusionPercutaneous interventionHistorical controlsAtherosclerotic lesionsTrial studyU.S. CentersLesions
2000
Procedural results and intermediate clinical outcomes after multiple saphenous vein graft stenting
Bhargava B, Kornowski R, Mehran R, Kent K, Hong M, Lansky A, Waksman R, Pichard A, Satler L, Leon M. Procedural results and intermediate clinical outcomes after multiple saphenous vein graft stenting. Journal Of The American College Of Cardiology 2000, 35: 389-397. PMID: 10676686, DOI: 10.1016/s0735-1097(99)00564-1.Peer-Reviewed Original ResearchConceptsMid-term clinical outcomesSVG interventionClinical outcomesProcedural successOverall cardiac event-free survivalCardiac event-free survivalSaphenous vein graft angioplastyNon-Q-wave MIHospital procedural successVein graft angioplastyEvent-free survivalIntermediate clinical outcomesMajor complication rateOverall procedural successSaphenous vein graftsGraft angioplastyLesion revascularizationSimultaneous stentingSVG diseaseSVG groupSVG stentingLate mortalityComplication rateDistal embolizationMI rates
1998
Procedural Results and Late Clinical Outcomes After Placement of Three or More Stents in Single Coronary Lesions
Kornowski R, Mehran R, Hong M, Satler L, Pichard A, Kent K, Mintz G, Waksman R, Laird J, Lansky A, Bucher T, Popma J, Leon M. Procedural Results and Late Clinical Outcomes After Placement of Three or More Stents in Single Coronary Lesions. Circulation 1998, 97: 1355-1361. PMID: 9577946, DOI: 10.1161/01.cir.97.14.1355.Peer-Reviewed Original ResearchConceptsNon-Q-wave MIUnfavorable lesion characteristicsClinical outcomesProcedural successMajor complicationsLesion characteristicsMultiple stentsOverall cardiac event-free survivalMajor cardiac event rateCardiac event-free survivalLong-term clinical outcomesCardiac event rateHospital procedural successLate clinical outcomesSingle coronary lesionsEvent-free survivalSaphenous vein graftsOverall procedural successRight coronary arteryLong-term complicationsQ-wave MILesion revascularizationConsecutive patientsCoronary lesionsLong dissection