2021
Use of Mechanical Circulatory Support Devices Among Patients With Acute Myocardial Infarction Complicated by Cardiogenic Shock
Dhruva SS, Ross JS, Mortazavi BJ, Hurley NC, Krumholz HM, Curtis JP, Berkowitz AP, Masoudi FA, Messenger JC, Parzynski CS, Ngufor CG, Girotra S, Amin AP, Shah ND, Desai NR. Use of Mechanical Circulatory Support Devices Among Patients With Acute Myocardial Infarction Complicated by Cardiogenic Shock. JAMA Network Open 2021, 4: e2037748. PMID: 33616664, PMCID: PMC7900859, DOI: 10.1001/jamanetworkopen.2020.37748.Peer-Reviewed Original ResearchMeSH KeywordsAgedAssisted CirculationCross-Sectional StudiesExtracorporeal Membrane OxygenationFemaleHeart ArrestHeart-Assist DevicesHospitals, High-VolumeHospitals, Low-VolumeHospitals, TeachingHumansIntra-Aortic Balloon PumpingMaleMiddle AgedMyocardial InfarctionPercutaneous Coronary InterventionRisk FactorsShock, CardiogenicConceptsMicroaxial left ventricular assist deviceIntra-aortic balloon pumpLeft ventricular assist devicePercutaneous coronary interventionAcute myocardial infarctionMechanical circulatory support devicesCardiogenic shockHospital-level variationSignificant hospital-level variationCirculatory support devicesMCS devicesUse of IABPDevice useMedian proportionAcute Myocardial Infarction ComplicatedCardiology-National Cardiovascular Data RegistryChest Pain-MI RegistryLimited clinical trial evidenceNational Cardiovascular Data RegistryMyocardial Infarction ComplicatedFirst medical contactSupport devicesClinical trial evidenceExtracorporeal membrane oxygenationCoronary artery stenosis
2020
Association of Use of an Intravascular Microaxial Left Ventricular Assist Device vs Intra-aortic Balloon Pump With In-Hospital Mortality and Major Bleeding Among Patients With Acute Myocardial Infarction Complicated by Cardiogenic Shock
Dhruva SS, Ross JS, Mortazavi BJ, Hurley NC, Krumholz HM, Curtis JP, Berkowitz A, Masoudi FA, Messenger JC, Parzynski CS, Ngufor C, Girotra S, Amin AP, Shah ND, Desai NR. Association of Use of an Intravascular Microaxial Left Ventricular Assist Device vs Intra-aortic Balloon Pump With In-Hospital Mortality and Major Bleeding Among Patients With Acute Myocardial Infarction Complicated by Cardiogenic Shock. JAMA 2020, 323: 734-745. PMID: 32040163, PMCID: PMC7042879, DOI: 10.1001/jama.2020.0254.Peer-Reviewed Original ResearchMeSH KeywordsAgedCause of DeathExtracorporeal Membrane OxygenationFemaleHeart ArrestHeart-Assist DevicesHemorrhageHospital MortalityHumansIntra-Aortic Balloon PumpingMaleMatched-Pair AnalysisMiddle AgedMyocardial InfarctionPercutaneous Coronary InterventionPropensity ScoreRegistriesRetrospective StudiesShock, CardiogenicST Elevation Myocardial InfarctionConceptsMicroaxial left ventricular assist deviceIntra-aortic balloon pumpLeft ventricular assist deviceAcute myocardial infarctionPercutaneous coronary interventionNational Cardiovascular Data RegistryCardiogenic shockHemodynamic supportMyocardial infarctionRegistry-based retrospective cohort studyCardiology-National Cardiovascular Data RegistryChest Pain-MI RegistryST-elevation myocardial infarctionMechanical circulatory support devicesGreater hemodynamic supportHospital major bleedingRetrospective cohort studyPropensity-matched pairsCirculatory support devicesVentricular assist deviceClinical laboratory dataHospital mortalityMajor bleedingHospital deathCohort study
2015
Use of Mechanical Circulatory Support in Patients Undergoing Percutaneous Coronary Intervention
Sandhu A, McCoy LA, Negi SI, Hameed I, Atri P, Al'Aref SJ, Curtis J, McNulty E, Anderson HV, Shroff A, Menegus M, Swaminathan RV, Gurm H, Messenger J, Wang T, Bradley SM. Use of Mechanical Circulatory Support in Patients Undergoing Percutaneous Coronary Intervention. Circulation 2015, 132: 1243-1251. PMID: 26286905, DOI: 10.1161/circulationaha.114.014451.Peer-Reviewed Original ResearchConceptsIntra-aortic balloon pumpPercutaneous coronary interventionMechanical circulatory supportUse of IABPCardiogenic shockCirculatory supportCoronary interventionNational Cardiovascular Data Registry CathPCISetting of PCIStudy periodProportion of patientsHospital-level variationLarge national registryHalf of hospitalsBalloon pumpNational registryPatientsHospitalInterventionConcurrent increaseSettingTemporal trendsCathPCIRegistryContemporary use
2011
Use and Effectiveness of Intra-Aortic Balloon Pumps Among Patients Undergoing High Risk Percutaneous Coronary Intervention
Curtis JP, Rathore SS, Wang Y, Chen J, Nallamothu BK, Krumholz HM. Use and Effectiveness of Intra-Aortic Balloon Pumps Among Patients Undergoing High Risk Percutaneous Coronary Intervention. Circulation Cardiovascular Quality And Outcomes 2011, 5: 21-30. PMID: 22147887, PMCID: PMC3801197, DOI: 10.1161/circoutcomes.110.960385.Peer-Reviewed Original ResearchConceptsHigh-risk percutaneous coronary interventionIntra-aortic balloon pumpPercutaneous coronary interventionHospital quartilesHospital mortalityIABP useCoronary interventionBalloon pumpHospital characteristicsST-segment elevation myocardial infarctionDepressed left ventricular functionHigh-risk PCI patientsSegment elevation myocardial infarctionElevation myocardial infarctionLeft ventricular functionHierarchical logistic regression modelsLogistic regression modelsIABP usageCardiogenic shockPCI patientsCathPCI RegistryHemodynamic supportVentricular functionHospital variationMultivariable analysis