2021
Use of Mechanical Circulatory Support Devices Among Patients With Acute Myocardial Infarction Complicated by Cardiogenic Shock
Dhruva SS, Ross JS, Mortazavi BJ, Hurley NC, Krumholz HM, Curtis JP, Berkowitz AP, Masoudi FA, Messenger JC, Parzynski CS, Ngufor CG, Girotra S, Amin AP, Shah ND, Desai NR. Use of Mechanical Circulatory Support Devices Among Patients With Acute Myocardial Infarction Complicated by Cardiogenic Shock. JAMA Network Open 2021, 4: e2037748. PMID: 33616664, PMCID: PMC7900859, DOI: 10.1001/jamanetworkopen.2020.37748.Peer-Reviewed Original ResearchMeSH KeywordsAgedAssisted CirculationCross-Sectional StudiesExtracorporeal Membrane OxygenationFemaleHeart ArrestHeart-Assist DevicesHospitals, High-VolumeHospitals, Low-VolumeHospitals, TeachingHumansIntra-Aortic Balloon PumpingMaleMiddle AgedMyocardial InfarctionPercutaneous Coronary InterventionRisk FactorsShock, CardiogenicConceptsMicroaxial left ventricular assist deviceIntra-aortic balloon pumpLeft ventricular assist devicePercutaneous coronary interventionAcute myocardial infarctionMechanical circulatory support devicesCardiogenic shockHospital-level variationSignificant hospital-level variationCirculatory support devicesMCS devicesUse of IABPDevice useMedian proportionAcute Myocardial Infarction ComplicatedCardiology-National Cardiovascular Data RegistryChest Pain-MI RegistryLimited clinical trial evidenceNational Cardiovascular Data RegistryMyocardial Infarction ComplicatedFirst medical contactSupport devicesClinical trial evidenceExtracorporeal membrane oxygenationCoronary artery stenosis
2020
Revascularization Practices and Outcomes in Patients With Multivessel Coronary Artery Disease Who Presented With Acute Myocardial Infarction and Cardiogenic Shock in the US, 2009-2018
Khera R, Secemsky EA, Wang Y, Desai NR, Krumholz HM, Maddox TM, Shunk KA, Virani SS, Bhatt DL, Curtis J, Yeh RW. Revascularization Practices and Outcomes in Patients With Multivessel Coronary Artery Disease Who Presented With Acute Myocardial Infarction and Cardiogenic Shock in the US, 2009-2018. JAMA Internal Medicine 2020, 180: 1317-1327. PMID: 32833024, PMCID: PMC9377424, DOI: 10.1001/jamainternmed.2020.3276.Peer-Reviewed Original ResearchMeSH KeywordsAdultAgedCohort StudiesCoronary VesselsFemaleFollow-Up StudiesHospital MortalityHumansMaleMiddle AgedMyocardial InfarctionPatient DischargePercutaneous Coronary InterventionRisk AssessmentRisk FactorsShock, CardiogenicST Elevation Myocardial InfarctionTime FactorsTreatment OutcomeUnited StatesConceptsST-segment elevation myocardial infarctionMultivessel percutaneous coronary interventionMultivessel coronary artery diseasePercutaneous coronary interventionAcute myocardial infarctionCoronary artery diseaseCulprit vessel percutaneous coronary interventionCardiogenic shockHospital mortalityArtery diseaseMyocardial infarctionCohort studyPrimary outcomeHospital variationPCI strategyMedicare beneficiariesUnderwent multivessel PCISignificant hospital variationElevation myocardial infarctionSubset of patientsHigh-risk populationRecent evidenceHospital complicationsPCI useRevascularization practiceContemporary Trends, Predictors and Outcomes of Perforation During Percutaneous Coronary Intervention (From the NCDR Cath PCI Registry)
Nairooz R, Parzynski CS, Curtis JP, Mohsen A, McNulty E, Uretsky BF, Hakeem A. Contemporary Trends, Predictors and Outcomes of Perforation During Percutaneous Coronary Intervention (From the NCDR Cath PCI Registry). The American Journal Of Cardiology 2020, 130: 37-45. PMID: 32665131, DOI: 10.1016/j.amjcard.2020.06.014.Peer-Reviewed Original ResearchConceptsPercutaneous coronary interventionCoronary artery perforationAdverse eventsCardiogenic shockStudy periodCoronary interventionChronic total occlusion (CTO) PCISaphenous vein graft percutaneous coronary interventionProportion of PCIsVein graft percutaneous coronary interventionNational Cardiovascular Data Registry CathPCI RegistryGraft percutaneous coronary interventionLargest real-world experienceCTO percutaneous coronary interventionComplex percutaneous coronary interventionMultivariable logistic regression modelNon-CP patientsOutcome of perforationTotal PCI volumeUse of atherectomyType C lesionsCoronary artery bypassHigh rateLife-threatening complicationsConcomitant significant increaseAssociation of Use of an Intravascular Microaxial Left Ventricular Assist Device vs Intra-aortic Balloon Pump With In-Hospital Mortality and Major Bleeding Among Patients With Acute Myocardial Infarction Complicated by Cardiogenic Shock
Dhruva SS, Ross JS, Mortazavi BJ, Hurley NC, Krumholz HM, Curtis JP, Berkowitz A, Masoudi FA, Messenger JC, Parzynski CS, Ngufor C, Girotra S, Amin AP, Shah ND, Desai NR. Association of Use of an Intravascular Microaxial Left Ventricular Assist Device vs Intra-aortic Balloon Pump With In-Hospital Mortality and Major Bleeding Among Patients With Acute Myocardial Infarction Complicated by Cardiogenic Shock. JAMA 2020, 323: 734-745. PMID: 32040163, PMCID: PMC7042879, DOI: 10.1001/jama.2020.0254.Peer-Reviewed Original ResearchMeSH KeywordsAgedCause of DeathExtracorporeal Membrane OxygenationFemaleHeart ArrestHeart-Assist DevicesHemorrhageHospital MortalityHumansIntra-Aortic Balloon PumpingMaleMatched-Pair AnalysisMiddle AgedMyocardial InfarctionPercutaneous Coronary InterventionPropensity ScoreRegistriesRetrospective StudiesShock, CardiogenicST Elevation Myocardial InfarctionConceptsMicroaxial left ventricular assist deviceIntra-aortic balloon pumpLeft ventricular assist deviceAcute myocardial infarctionPercutaneous coronary interventionNational Cardiovascular Data RegistryCardiogenic shockHemodynamic supportMyocardial infarctionRegistry-based retrospective cohort studyCardiology-National Cardiovascular Data RegistryChest Pain-MI RegistryST-elevation myocardial infarctionMechanical circulatory support devicesGreater hemodynamic supportHospital major bleedingRetrospective cohort studyPropensity-matched pairsCirculatory support devicesVentricular assist deviceClinical laboratory dataHospital mortalityMajor bleedingHospital deathCohort study
2015
Use of Mechanical Circulatory Support in Patients Undergoing Percutaneous Coronary Intervention
Sandhu A, McCoy LA, Negi SI, Hameed I, Atri P, Al'Aref SJ, Curtis J, McNulty E, Anderson HV, Shroff A, Menegus M, Swaminathan RV, Gurm H, Messenger J, Wang T, Bradley SM. Use of Mechanical Circulatory Support in Patients Undergoing Percutaneous Coronary Intervention. Circulation 2015, 132: 1243-1251. PMID: 26286905, DOI: 10.1161/circulationaha.114.014451.Peer-Reviewed Original ResearchConceptsIntra-aortic balloon pumpPercutaneous coronary interventionMechanical circulatory supportUse of IABPCardiogenic shockCirculatory supportCoronary interventionNational Cardiovascular Data Registry CathPCISetting of PCIStudy periodProportion of patientsHospital-level variationLarge national registryHalf of hospitalsBalloon pumpNational registryPatientsHospitalInterventionConcurrent increaseSettingTemporal trendsCathPCIRegistryContemporary use
2014
Validated Contemporary Risk Model of Acute Kidney Injury in Patients Undergoing Percutaneous Coronary Interventions: Insights From the National Cardiovascular Data Registry Cath‐PCI Registry
Tsai TT, Patel UD, Chang TI, Kennedy KF, Masoudi FA, Matheny ME, Kosiborod M, Amin AP, Weintraub WS, Curtis JP, Messenger JC, Rumsfeld JS, Spertus JA. Validated Contemporary Risk Model of Acute Kidney Injury in Patients Undergoing Percutaneous Coronary Interventions: Insights From the National Cardiovascular Data Registry Cath‐PCI Registry. Journal Of The American Heart Association 2014, 3: e001380. PMID: 25516439, PMCID: PMC4338731, DOI: 10.1161/jaha.114.001380.Peer-Reviewed Original ResearchMeSH KeywordsAcute Kidney InjuryAge FactorsAgedBiomarkersComorbidityCreatinineDecision Support TechniquesFemaleGlomerular Filtration RateHumansKidneyMaleMiddle AgedPercutaneous Coronary InterventionPredictive Value of TestsRegistriesRenal DialysisReproducibility of ResultsRisk AssessmentRisk FactorsSeverity of Illness IndexTreatment OutcomeUnited StatesConceptsAcute kidney injuryPercutaneous coronary interventionCardiogenic shockKidney injuryCoronary interventionHeart failureValidation cohortPreventative strategiesRisk of PCIPrior percutaneous coronary interventionAKI prediction modelBaseline renal impairmentConsecutive PCI patientsContemporary risk modelsPrior cerebrovascular diseasePrior heart failureChronic lung diseaseRisk-stratify patientsLocal quality improvement effortsQuality improvement effortsGood discriminationBaseline CKDSTEMI presentationPCI patientsPCI registry
2013
Enhanced Mortality Risk Prediction With a Focus on High-Risk Percutaneous Coronary Intervention Results From 1,208,137 Procedures in the NCDR (National Cardiovascular Data Registry)
Brennan JM, Curtis JP, Dai D, Fitzgerald S, Khandelwal AK, Spertus JA, Rao SV, Singh M, Shaw RE, Ho KK, Krone RJ, Weintraub WS, Weaver WD, Peterson ED, Registry C. Enhanced Mortality Risk Prediction With a Focus on High-Risk Percutaneous Coronary Intervention Results From 1,208,137 Procedures in the NCDR (National Cardiovascular Data Registry). JACC Cardiovascular Interventions 2013, 6: 790-799. PMID: 23968699, DOI: 10.1016/j.jcin.2013.03.020.Peer-Reviewed Original ResearchMeSH KeywordsAgedAged, 80 and overCoronary AngiographyCoronary Artery DiseaseDiscriminant AnalysisFemaleHeart ArrestHospital MortalityHumansLogistic ModelsMaleMiddle AgedMultivariate AnalysisOdds RatioPercutaneous Coronary InterventionRegistriesReproducibility of ResultsRisk AssessmentRisk FactorsShock, CardiogenicTime FactorsTreatment OutcomeUnited StatesConceptsPercutaneous coronary interventionRecent cardiac arrestCardiogenic shockInpatient mortalityCardiac arrestPercutaneous Coronary Intervention ResultsBedside risk scoreMain lesion locationHigh-risk patientsChronic total occlusionHigh clinical riskRisk of deathHospital mortality risk modelPre-specified patient subgroupsMortality risk predictionMortality risk modelData collection formRisk prediction modelPCI riskHospital mortalityProcedural mortalityAngiographic predictorsCoronary interventionRisk patientsClinical stability
2012
Development of 2 Registry-Based Risk Models Suitable for Characterizing Hospital Performance on 30-Day All-Cause Mortality Rates Among Patients Undergoing Percutaneous Coronary Intervention
Curtis JP, Geary LL, Wang Y, Chen J, Drye EE, Grosso LM, Spertus JA, Rumsfeld JS, Weintraub WS, Masoudi FA, Brindis RG, Krumholz HM. Development of 2 Registry-Based Risk Models Suitable for Characterizing Hospital Performance on 30-Day All-Cause Mortality Rates Among Patients Undergoing Percutaneous Coronary Intervention. Circulation Cardiovascular Quality And Outcomes 2012, 5: 628-637. PMID: 22949491, DOI: 10.1161/circoutcomes.111.964569.Peer-Reviewed Original ResearchMeSH KeywordsAcute Coronary SyndromeAgedAged, 80 and overAngina PectorisChi-Square DistributionComorbidityFemaleHeart DiseasesHospital MortalityHospitalsHumansLogistic ModelsMaleMyocardial InfarctionOdds RatioOutcome and Process Assessment, Health CarePercutaneous Coronary InterventionQuality Indicators, Health CareRegistriesRisk AssessmentRisk FactorsShock, CardiogenicTime FactorsTreatment OutcomeUnited StatesConceptsST-segment elevation myocardial infarctionPercutaneous coronary interventionRisk-standardized mortality ratesElevation myocardial infarctionPatient mortality ratesMyocardial infarctionMortality rateCardiogenic shockCoronary interventionDerivation cohortHospital risk-standardized mortality ratesCause mortality ratesAdministrative claims dataQuality of careHierarchical logistic regression modelsNational Quality ForumLogistic regression modelsObserved mortality rateCathPCI RegistryNational HospitalClaims dataInfarctionPatientsQuality ForumFinal model
2011
Use and Effectiveness of Intra-Aortic Balloon Pumps Among Patients Undergoing High Risk Percutaneous Coronary Intervention
Curtis JP, Rathore SS, Wang Y, Chen J, Nallamothu BK, Krumholz HM. Use and Effectiveness of Intra-Aortic Balloon Pumps Among Patients Undergoing High Risk Percutaneous Coronary Intervention. Circulation Cardiovascular Quality And Outcomes 2011, 5: 21-30. PMID: 22147887, PMCID: PMC3801197, DOI: 10.1161/circoutcomes.110.960385.Peer-Reviewed Original ResearchConceptsHigh-risk percutaneous coronary interventionIntra-aortic balloon pumpPercutaneous coronary interventionHospital quartilesHospital mortalityIABP useCoronary interventionBalloon pumpHospital characteristicsST-segment elevation myocardial infarctionDepressed left ventricular functionHigh-risk PCI patientsSegment elevation myocardial infarctionElevation myocardial infarctionLeft ventricular functionHierarchical logistic regression modelsLogistic regression modelsIABP usageCardiogenic shockPCI patientsCathPCI RegistryHemodynamic supportVentricular functionHospital variationMultivariable analysis