1998
Exercise testing with myocardial perfusion imaging in patients with normal baseline electrocardiograms: Cost savings with a stepwise diagnostic strategy
Mattera J, Arain S, Sinusas A, Finta L, Wackers F. Exercise testing with myocardial perfusion imaging in patients with normal baseline electrocardiograms: Cost savings with a stepwise diagnostic strategy. Journal Of Nuclear Cardiology 1998, 5: 498-506. PMID: 9796897, DOI: 10.1016/s1071-3581(98)90181-7.Peer-Reviewed Original ResearchConceptsExercise myocardial perfusion imagingCoronary artery diseaseNormal exercise electrocardiogramMyocardial perfusion imagingNormal myocardial perfusion imagingNormal resting electrocardiogramsExercise electrocardiogramExercise testingArtery diseaseIntermediate likelihoodResting electrocardiogramsAbnormal myocardial perfusion imagingDiagnostic strategiesAbnormal exercise electrocardiogramGroup 3 patientsHard cardiac eventsNonfatal myocardial infarctionNormal baseline electrocardiogramSubsequent coronary revascularizationIncremental diagnostic informationDiagnostic testing strategiesCoronary revascularizationCardiac eventsUnstable anginaConsecutive patients
1996
Quantitative comparison of planar and SPECT normal data files of thallium-201, technetium-99m-sestamibi, technetium-99m-tetrofosmin and technetium-99m-furifosmin.
Naruse H, Daher E, Sinusas A, Jain D, Natale D, Mattera J, Makuch R, Wackers FJ. Quantitative comparison of planar and SPECT normal data files of thallium-201, technetium-99m-sestamibi, technetium-99m-tetrofosmin and technetium-99m-furifosmin. Journal Of Nuclear Medicine 1996, 37: 1783-8. PMID: 8917175.Peer-Reviewed Original Research
1991
Thallium-201 for assessment of myocardial viability: Quantitative comparison of 24-hour redistribution imaging with imaging after reinjection at rest
Kayden D, Sigal S, Soufer R, Mattera J, Zaret B, Wackers F. Thallium-201 for assessment of myocardial viability: Quantitative comparison of 24-hour redistribution imaging with imaging after reinjection at rest. Journal Of The American College Of Cardiology 1991, 18: 1480-1486. PMID: 1939949, DOI: 10.1016/0735-1097(91)90678-3.Peer-Reviewed Original ResearchConceptsInjection of thalliumRedistribution imagesDefect reversibilityThallium-201 reinjectionThallium-201 defectsLate redistribution imagingPoor quality studiesDiagnostic informationClinical variablesRedistribution imagingThallium defectsThallium imagesMyocardial viabilityReversible defectsStress imagingThallium-201PatientsBetter diagnostic informationStress testingExercisePresent studyQuality studiesInjectionLate redistributionReinjection
1990
Quantitative analysis of planar technetium-99m-sestamibi myocardial perfusion images using modified background subtraction.
Koster K, Wackers F, Mattera J, Fetterman R. Quantitative analysis of planar technetium-99m-sestamibi myocardial perfusion images using modified background subtraction. Journal Of Nuclear Medicine 1990, 31: 1400-8. PMID: 2143529.Peer-Reviewed Original Research