Spontaneous reversal of stenosis in tissue-engineered vascular grafts
Drews JD, Pepper VK, Best CA, Szafron JM, Cheatham JP, Yates AR, Hor KN, Zbinden JC, Chang YC, Mirhaidari GJM, Ramachandra AB, Miyamoto S, Blum KM, Onwuka EA, Zakko J, Kelly J, Cheatham SL, King N, Reinhardt JW, Sugiura T, Miyachi H, Matsuzaki Y, Breuer J, Heuer ED, West TA, Shoji T, Berman D, Boe BA, Asnes J, Galantowicz M, Matsumura G, Hibino N, Marsden AL, Pober JS, Humphrey JD, Shinoka T, Breuer CK. Spontaneous reversal of stenosis in tissue-engineered vascular grafts. Science Translational Medicine 2020, 12 PMID: 32238576, PMCID: PMC7478265, DOI: 10.1126/scitranslmed.aax6919.Peer-Reviewed Original ResearchMeSH KeywordsAnimalsBlood Vessel ProsthesisChildConstriction, PathologicHumansSheepTissue EngineeringUnited StatesConceptsEarly stenosisInferior venaClinical trialsAppropriate medical monitoringTissue-engineered vascular graftsVascular graftsTEVG stenosisPulmonary arteryCardiac anomaliesClinical managementEarly inflammationHigh incidenceStenosisFontan conduitDrug AdministrationGraft modelReversible narrowingGraftU.S. FoodTranslational researchAngioplastyVenaPatientsSpontaneous reversalTrials
2018
Initial results from the off‐label use of the SAPIEN S3 valve for percutaneous transcatheter pulmonary valve replacement: A multi‐institutional experience
Sinha S, Aboulhosn J, Asnes J, Bocks M, Zahn E, Goldstein BH, Zampi J, Hellenbrand W, Salem M, Levi D. Initial results from the off‐label use of the SAPIEN S3 valve for percutaneous transcatheter pulmonary valve replacement: A multi‐institutional experience. Catheterization And Cardiovascular Interventions 2018, 93: 455-463. PMID: 30537348, DOI: 10.1002/ccd.27973.Peer-Reviewed Original ResearchMeSH KeywordsAdolescentAdultBalloon ValvuloplastyCardiac CatheterizationCardiac Surgical ProceduresChildFemaleHeart Defects, CongenitalHeart Valve ProsthesisHeart Valve Prosthesis ImplantationHumansMalePostoperative ComplicationsProsthesis DesignPulmonary ValvePulmonary Valve InsufficiencyRecovery of FunctionRetrospective StudiesRisk FactorsTime FactorsTreatment OutcomeUnited StatesYoung AdultConceptsTranscatheter pulmonary valve replacementRight ventricular outflow tractDysfunctional right ventricular outflow tractsSapien S3 valvePercutaneous transcatheter pulmonary valve replacementCongenital heart diseaseTricuspid valve injuryPulmonary valve replacementS3 valveSAPIEN S3Valve injuryValve replacementNative right ventricular outflow tractSerious procedural complicationsVentricular outflow tractMulti-center experienceMulti-institutional experienceOff-label useShort-term resultsAortic compressionValve embolizationPerivalvular leakProcedural deathsClinical followMajor complicationsTranscatheter Pulmonary Valve Replacement With the Melody Valve in Small Diameter Expandable Right Ventricular Outflow Tract Conduits
Shahanavaz S, Qureshi AM, Levi DS, Boudjemline Y, Peng LF, Martin MH, Bauser-Heaton H, Keeshan B, Asnes JD, Jones TK, Justino H, Aboulhosn JA, Gray RG, Nguyen H, Balzer DT, McElhinney DB. Transcatheter Pulmonary Valve Replacement With the Melody Valve in Small Diameter Expandable Right Ventricular Outflow Tract Conduits. JACC Cardiovascular Interventions 2018, 11: 554-564. PMID: 29566801, DOI: 10.1016/j.jcin.2018.01.239.Peer-Reviewed Original ResearchMeSH KeywordsAdolescentAdultAngiographyBlood Vessel ProsthesisBlood Vessel Prosthesis ImplantationCardiac CatheterizationChildChild, PreschoolFeasibility StudiesFemaleGraft Occlusion, VascularHeart Valve ProsthesisHeart Valve Prosthesis ImplantationHemodynamicsHumansMalePreliminary DataProsthesis DesignPulmonary ValveRetrospective StudiesTime FactorsTreatment OutcomeUnited StatesVentricular Outflow ObstructionYoung AdultConceptsTranscatheter pulmonary valve replacementRight ventricular outflow tractPulmonary valve replacementMelody valveValve replacementDysfunctional right ventricular outflow tractsPercutaneous transcatheter pulmonary valve replacementSuccessful transcatheter pulmonary valve replacementSignificant hemodynamic improvementSignificant pulmonary regurgitationVentricular outflow tractCases of endocarditisRVOT reinterventionHemodynamic improvementPulmonary regurgitationHemodynamic outcomesOutflow tractProcedural characteristicsPreliminary experiencePatientsSmall diameter conduitsLimited dataOutcomesSmall conduitsReintervention
2017
Transcatheter pulmonary valve replacement using the melody valve for treatment of dysfunctional surgical bioprostheses: A multicenter study
Cabalka AK, Asnes JD, Balzer DT, Cheatham JP, Gillespie MJ, Jones TK, Justino H, Kim DW, Lung TH, Turner DR, McElhinney DB. Transcatheter pulmonary valve replacement using the melody valve for treatment of dysfunctional surgical bioprostheses: A multicenter study. Journal Of Thoracic And Cardiovascular Surgery 2017, 155: 1712-1724.e1. PMID: 29395214, DOI: 10.1016/j.jtcvs.2017.10.143.Peer-Reviewed Original ResearchMeSH KeywordsAdolescentAdultAgedBioprosthesisCardiac CatheterizationChildChild, PreschoolFemaleHeart Valve ProsthesisHeart Valve Prosthesis ImplantationHumansMaleMiddle AgedProsthesis DesignProsthesis FailurePulmonary ValvePulmonary Valve InsufficiencyPulmonary Valve StenosisRecovery of FunctionRetrospective StudiesTime FactorsTreatment OutcomeUnited StatesYoung AdultConceptsPulmonary valve replacementTPV replacementPulmonary regurgitationBioprosthetic valvesValve replacementMulticenter studyRight ventricular outflow tract gradientPostoperative congenital heart diseaseTranscatheter pulmonary valve replacementVentricular outflow tract gradientSurgical pulmonary valve replacementMean RVOT gradientMedian patient ageOutflow tract gradientSevere pulmonary regurgitationExcellent early resultsSurgical bioprosthetic valvesTetralogy of FallotCongenital heart diseaseTime-related fashionRVOT gradientTract gradientUnderlying diagnosisHospital dischargePatient agePercutaneous transcatheter pulmonary valve replacement in children weighing less than 20 kg
Martin MH, Shahanavaz S, Peng LF, Asnes JD, Riley M, Hellenbrand WE, Balzer DT, Gray RG, McElhinney DB. Percutaneous transcatheter pulmonary valve replacement in children weighing less than 20 kg. Catheterization And Cardiovascular Interventions 2017, 91: 485-494. PMID: 29193671, DOI: 10.1002/ccd.27432.Peer-Reviewed Original ResearchMeSH KeywordsAge FactorsBody WeightCardiac CatheterizationChildChild DevelopmentChild, PreschoolCoronary AngiographyEchocardiography, DopplerFemaleHeart Valve ProsthesisHeart Valve Prosthesis ImplantationHumansMalePostoperative ComplicationsPulmonary ValveRetrospective StudiesRisk FactorsTreatment OutcomeUnited StatesConceptsTranscatheter pulmonary valve replacementPercutaneous transcatheter pulmonary valve replacementPulmonary valve replacementTetralogy of FallotValve replacementVein accessInternal jugular vein accessExcellent valve functionMean Doppler gradientMild pulmonary regurgitationIliac vein injuryCases of endocarditisFemoral vein accessSuccessful valve implantationJugular vein accessIJV accessRVOT reinterventionMelody valveAdverse eventsDoppler gradientPulmonary regurgitationValve implantationMedian ageVein injuryRoot compression
2008
Causes of Recurrent Focal Neurologic Events After Transcatheter Closure of Patent Foramen Ovale With the CardioSEAL Septal Occluder
Kutty S, Brown K, Asnes JD, Rhodes JF, Latson LA. Causes of Recurrent Focal Neurologic Events After Transcatheter Closure of Patent Foramen Ovale With the CardioSEAL Septal Occluder. The American Journal Of Cardiology 2008, 101: 1487-1492. PMID: 18471463, DOI: 10.1016/j.amjcard.2008.01.028.Peer-Reviewed Original ResearchMeSH KeywordsAdultAgedCardiac CatheterizationCatheterizationConfidence IntervalsEmbolism, ParadoxicalEquipment DesignFemaleFollow-Up StudiesForamen Ovale, PatentHumansIncidenceIschemic Attack, TransientMagnetic Resonance ImagingMaleMiddle AgedPrognosisProportional Hazards ModelsRecurrenceRetrospective StudiesRisk FactorsStrokeTime FactorsTomography, X-Ray ComputedTreatment OutcomeUnited StatesConceptsStroke/transient ischemic attackTransient ischemic attackFocal neurologic eventsPFO closureRecurrent strokeNeurologic eventsMedical managementRecurrent stroke/transient ischemic attackEvent ratesOngoing randomized trialsPatent foramen ovaleTranscatheter PFO closureTranscatheter patent foramenCardioSEAL Septal OccluderEmbolic episodesIschemic attackPFO occlusionParadoxical emboliImmediate morbidityConsecutive patientsPatent foramenRandomized trialsTranscatheter closureForamen ovaleRecurrence rate