2024
Data-driven non-rigid motion detection and correction for NeuroEXPLORER
Zhang J, Sun C, Volpi T, Zeng T, Fontaine K, Du Y, Toyonaga T, Onofrey J, Lu Y, Carson R. Data-driven non-rigid motion detection and correction for NeuroEXPLORER. 2024, 00: 1-2. DOI: 10.1109/nss/mic/rtsd57108.2024.10658289.Peer-Reviewed Original ResearchNon-rigid motionNon-rigid motion estimationMotion dataNon-rigid regionsHead motion dataTracking capabilityMotion estimationMotion detectionRigid transformationImage-derived input functionMotion tracking systemImage blurringCarotid arteryEffective MCMotion patternsPatient movementTracking systemMotion correction frameworkBrain PET systemRigid motionMotion-corrected reconstructionFacial surfaceRigid motion correctionCorrect reconstructionCorrection framework
2020
Data-Driven Motion Detection and Event-by-Event Correction for Brain PET: Comparison with Vicra
Lu Y, Naganawa M, Toyonaga T, Gallezot JD, Fontaine K, Ren S, Revilla EM, Mulnix T, Carson RE. Data-Driven Motion Detection and Event-by-Event Correction for Brain PET: Comparison with Vicra. Journal Of Nuclear Medicine 2020, 61: 1397-1403. PMID: 32005770, PMCID: PMC7456171, DOI: 10.2967/jnumed.119.235515.Peer-Reviewed Original ResearchConceptsData-driven algorithmMotion correction methodMotion tracking informationHead motionCentroid of distributionMotion-compensated reconstructionLarge head motionsMotion correction frameworkUser-defined thresholdPET raw dataDynamic datasetsTracking informationImage registrationMotion detectionRaw dataSuch time pointsImage qualityBetter performanceMotion correctionAlgorithmLine of responseCorrection frameworkBrain PET studiesCentral coordinatesTracer kinetic modeling
2018
Respiratory Motion Compensation for PET/CT with Motion Information Derived from Matched Attenuation-Corrected Gated PET Data
Lu Y, Fontaine K, Mulnix T, Onofrey JA, Ren S, Panin V, Jones J, Casey ME, Barnett R, Kench P, Fulton R, Carson RE, Liu C. Respiratory Motion Compensation for PET/CT with Motion Information Derived from Matched Attenuation-Corrected Gated PET Data. Journal Of Nuclear Medicine 2018, 59: 1480-1486. PMID: 29439015, PMCID: PMC6126443, DOI: 10.2967/jnumed.117.203000.Peer-Reviewed Original ResearchConceptsMotion correction frameworkMotion informationReference gatePET reconstructionMotion estimation accuracyGated PET dataMotion compensation approachMotion correctionMotion compensation methodMotion estimationRespiratory motion compensationAttenuation correction artifactsLung cancer datasetMotion compensationCT imagesNAC approachReconstruction algorithmPET dataPET imagesNew frameworkInaccurate localizationCancer datasetsBreathing variationsAttenuation correction mapsHuman datasets