2020
First-in-Human Evaluation of 18F-SynVesT-1, a Radioligand for PET Imaging of Synaptic Vesicle Glycoprotein 2A
Naganawa M, Li S, Nabulsi N, Henry S, Zheng MQ, Pracitto R, Cai Z, Gao H, Kapinos M, Labaree D, Matuskey D, Huang Y, Carson RE. First-in-Human Evaluation of 18F-SynVesT-1, a Radioligand for PET Imaging of Synaptic Vesicle Glycoprotein 2A. Journal Of Nuclear Medicine 2020, 62: 561-567. PMID: 32859701, PMCID: PMC8049363, DOI: 10.2967/jnumed.120.249144.Peer-Reviewed Original ResearchConceptsC-UCBSynaptic densityRegional time-activity curvesTime-activity curvesDistribution volumeMetabolite-corrected arterial input functionPET imagingMultilinear analysis 1Synaptic vesicle glycoprotein 2AAntiepileptic drug levetiracetamTotal distribution volumeNondisplaceable distribution volumeCentrum semiovaleBlocking doseHealthy volunteersHuman studiesDrug levetiracetamLassen plotNeuropsychiatric disordersPET radioligandArterial input functionNonhuman primatesLevetiracetamReference regionRadioligandFirst-in-Human Assessment of 11C-LSN3172176, an M1 Muscarinic Acetylcholine Receptor PET Radiotracer
Naganawa M, Nabulsi N, Henry S, Matuskey D, Lin SF, Slieker L, Schwarz AJ, Kant N, Jesudason C, Ruley K, Navarro A, Gao H, Ropchan J, Labaree D, Carson RE, Huang Y. First-in-Human Assessment of 11C-LSN3172176, an M1 Muscarinic Acetylcholine Receptor PET Radiotracer. Journal Of Nuclear Medicine 2020, 62: 553-560. PMID: 32859711, PMCID: PMC8049371, DOI: 10.2967/jnumed.120.246967.Peer-Reviewed Original ResearchConceptsSimplified reference tissue modelM1 receptorsHealthy subjectsMuscarinic acetylcholine receptor subtype M1Distribution volumePET radiotracersAbsolute test-retest variabilityExcellent test-retest reproducibilityReference tissue model 2Total distribution volumeSuitable reference regionTest-retest reproducibilityTest-retest variabilityReference regionTest-retest protocolNondisplaceable distribution volumeReference tissue modelTest-retest studySubtypes M1Preclinical studiesRegional time-activity curvesAcetylcholine concentrationHuman studiesReceptor occupancyTime-activity curves
2019
Imaging the Enzyme 11β-Hydroxysteroid Dehydrogenase Type 1 with PET: Evaluation of the Novel Radiotracer 11C-AS2471907 in Human Brain
Gallezot JD, Nabulsi N, Henry S, Pracitto R, Planeta B, Ropchan J, Lin SF, Labaree D, Kapinos M, Shirali A, Lara-Jaime T, Gao H, Matuskey D, Walzer M, Marek GJ, Bellaire S, Yuan N, Carson RE, Huang Y. Imaging the Enzyme 11β-Hydroxysteroid Dehydrogenase Type 1 with PET: Evaluation of the Novel Radiotracer 11C-AS2471907 in Human Brain. Journal Of Nuclear Medicine 2019, 60: 1140-1146. PMID: 30877174, DOI: 10.2967/jnumed.118.219766.Peer-Reviewed Original ResearchConceptsTest-retest variabilityNondisplaceable distribution volumeOccipital cortexEnzyme 11β-hydroxysteroid dehydrogenase type 1White matterDistribution volumeTreatment of depressionDehydrogenase type 1Large cortical regionsPosttraumatic stress disorderHuman brainAdditional scansIntraclass correlation coefficientAge-related cognitive functionBolus administrationFrontal cortexCaudate nucleusAdipose tissueTime-activity curvesNovel radiotracersGlucocorticoid levelsParietal cortexCortical regionsPattern of uptakeType 1
2016
Synthesis and Preclinical Evaluation of 11C-UCB-J as a PET Tracer for Imaging the Synaptic Vesicle Glycoprotein 2A in the Brain
Nabulsi N, Mercier J, Holden D, Carré S, Najafzadeh S, Vandergeten MC, Lin SF, Deo A, Price N, Wood M, Lara-Jaime T, Montel F, Laruelle M, Carson RE, Hannestad J, Huang Y. Synthesis and Preclinical Evaluation of 11C-UCB-J as a PET Tracer for Imaging the Synaptic Vesicle Glycoprotein 2A in the Brain. Journal Of Nuclear Medicine 2016, 57: 777-784. PMID: 26848175, DOI: 10.2967/jnumed.115.168179.Peer-Reviewed Original ResearchConceptsSynaptic vesicle glycoprotein 2AWhole-body biodistributionPET radiotracersNonhuman primatesDose-limiting organHigher free fractionGray matter regionsBaseline VTNondisplaceable distribution volumeAntiepileptic drugsVitro inhibition constantSynaptic densityPreclinical evaluationMonkey brainDistribution volumeArterial samplingEndocrine cellsRegional volumesMatter regionsRhesus macaquesPET tracersUCBFree fractionBrainTarget occupancy
2014
Kinetic Modeling of 11C-LY2795050, A Novel Antagonist Radiotracer for PET Imaging of the Kappa Opioid Receptor in Humans
Naganawa M, Zheng MQ, Nabulsi N, Tomasi G, Henry S, Lin SF, Ropchan J, Labaree D, Tauscher J, Neumeister A, Carson RE, Huang Y. Kinetic Modeling of 11C-LY2795050, A Novel Antagonist Radiotracer for PET Imaging of the Kappa Opioid Receptor in Humans. Cerebrovascular And Brain Metabolism Reviews 2014, 34: 1818-1825. PMID: 25182664, PMCID: PMC4269759, DOI: 10.1038/jcbfm.2014.150.Peer-Reviewed Original ResearchConceptsKappa-opioid receptorsMultilinear analysis 1Opioid receptorsNovel kappa opioid receptorDistribution volumePositron emission tomography (PET) imagingEmission Tomography ImagingLow intersubject variabilityTwo-tissue compartment modelAntagonist radiotracersOral naltrexoneNondisplaceable distribution volumeBaseline scanLY2795050Human studiesArterial input functionPET imagingTomography imagingIntersubject variabilityNaltrexone