2023
Simulation results for limited-angle ultra-high time-of-flight resolution PET system
Marin T, Zhuo Y, Orehar M, Razdevšekc G, Dolenec R, Mounime I, Alamo J, Benlloch J, Chemli Y, Fernández-Tenllado J, Gascon D, Gola A, Gomez S, Grogg K, Guberman D, Korpar S, Krizan P, Majewski S, Manera R, Mariscal-Castilla A, Mauricio J, Merzi S, Morera C, Normandin M, Pavon G, Penna M, Seljak A, Studen A, Pestotnik R, Fakhri G. Simulation results for limited-angle ultra-high time-of-flight resolution PET system. 2023, 00: 1-1. DOI: 10.1109/nssmicrtsd49126.2023.10337821.Peer-Reviewed Original ResearchResolution PET systemsPET systemAxial fieldPositron emission tomography systemPositron emission tomography scannerTotal-body PET systemsLong axial fieldTOF resolutionNovel detectorNumerical phantomHigh-sensitivity systemMonte-Carlo simulationsSpatial resolutionPositron emission tomographyMonte-CarloSystem sensitivityImage resolutionImage qualityScintillationReconstruction engineFWHMResolutionTOFPhantomScannerImaging Performance of the Fully Assembled Ultra-High Resolution (UHR) Brain PET scanner
Loignon-Houle F, Toussaint M, Beaudoin J, Gaudreault M, Doyon V, Leroux J, Auger E, Thibaudeau C, Arpin L, Croteau E, Espinosa-Bentancourt E, Samson A, Bouchard J, Espagnet R, Viscogliosi N, Pepin C, Labrecque V, Paulin C, Marin T, Ouyang J, Normandin M, Tétrault M, Michaud J, Fontaine R, Fakhri G, Lecomte R. Imaging Performance of the Fully Assembled Ultra-High Resolution (UHR) Brain PET scanner. 2023, 00: 1-1. DOI: 10.1109/nssmicrtsd49126.2023.10338146.Peer-Reviewed Original ResearchBrain PET scannerUltra-high resolutionPET scannerPeak noise-equivalent count rateUltra Micro Hot Spot PhantomNoise-equivalent count rateAxial field-of-viewHot spot phantomHoffman brain phantomSmall-scale structuresCount rateBrain phantomContrast recoveryReadout schemeField of viewBrain PET imagingPhantomExcellent image qualityImaging performanceSpatial resolutionSmall structuresUltrahigh resolutionImage qualityPET imagingLarger rodsImpact of motion correction on [18F]-MK6240 tau PET imaging
Tiss A, Marin T, Chemli Y, Spangler-Bickell M, Gong K, Lois C, Petibon Y, Landes V, Grogg K, Normandin M, Becker A, Thibault E, Johnson K, Fakhri G, Ouyang J. Impact of motion correction on [18F]-MK6240 tau PET imaging. Physics In Medicine And Biology 2023, 68: 105015. PMID: 37116511, PMCID: PMC10278956, DOI: 10.1088/1361-6560/acd161.Peer-Reviewed Original ResearchConceptsMotion correctionPET quantitationImpact of motion correctionList-mode reconstructionMotion correction methodList-mode dataMotion-corrected imagesEffect of motion correctionVoxel displacementsPhantom experimentsOptical tracking dataLong acquisitionBrain PET scansSlow motionImage qualityPET imagingPositron emission tomographyCorrectionMotionCorrection methodRates of tau accumulationHead motionMotion metricsPhantomPositronSuper-resolution in brain positron emission tomography using a real-time motion capture system
Chemli Y, Tétrault M, Marin T, Normandin M, Bloch I, El Fakhri G, Ouyang J, Petibon Y. Super-resolution in brain positron emission tomography using a real-time motion capture system. NeuroImage 2023, 272: 120056. PMID: 36977452, PMCID: PMC10122782, DOI: 10.1016/j.neuroimage.2023.120056.Peer-Reviewed Original ResearchConceptsBrain positron emission tomographySuper-resolutionEvent-by-event basisReal-time motion capture systemSR reconstruction methodTracking cameraVisualization of small structuresPET reconstruction algorithmMoving phantomMeasure target motionLine profilesPET/CT scannerMeasured shiftsImprove image resolutionMotion capture systemMotion tracking devicePositron emission tomographyReconstruction algorithmSpatial resolutionMeasured linesPhantomReal-timeEstimation frameworkIncreased spatial resolutionReconstruction method
2015
National Electrical Manufacturers Association and Clinical Evaluation of a Novel Brain PET/CT Scanner
Grogg K, Toole T, Ouyang J, Zhu X, Normandin M, Li Q, Johnson K, Alpert N, Fakhri G. National Electrical Manufacturers Association and Clinical Evaluation of a Novel Brain PET/CT Scanner. Journal Of Nuclear Medicine 2015, 57: 646-652. PMID: 26697961, PMCID: PMC4818715, DOI: 10.2967/jnumed.115.159723.Peer-Reviewed Original ResearchConceptsNoise-equivalent count rateCount rateLoose cutsMaximum noise-equivalent counting rateSpatial resolutionDetector ringSilicon photomultipliersBrain phantomContrast recoveryAttenuation correctionPET/CT systemCrystal blockPET/CT scannerImage qualityRadial offsetNational Electrical Manufacturers AssociationActivity distributionUnique mobility capabilitiesAxial extentTransverse resolutionPhantomAxial resolutionActivity concentrationsHuman scansLayer 1 cmMapping 15O Production Rate for Proton Therapy Verification
Grogg K, Alpert N, Zhu X, Min C, Testa M, Winey B, Normandin M, Shih H, Paganetti H, Bortfeld T, Fakhri G. Mapping 15O Production Rate for Proton Therapy Verification. International Journal Of Radiation Oncology • Biology • Physics 2015, 92: 453-459. PMID: 25817530, PMCID: PMC4431894, DOI: 10.1016/j.ijrobp.2015.01.023.Peer-Reviewed Original ResearchConceptsDecay constantProton treatment planningMonte Carlo predictionsProton therapyPhantom materialTreatment deliveryPhantomThigh activityPositron emission tomographyProduction rateDynamic PET measurementsTreatment planningRabbit thigh muscleClearance rateProtonIsotopesChanges due to therapyRadionuclide speciesOxygen-15ConstantDecayImaging targetsMontePositronEffects of perfusion
2014
Motion compensation for brain PET imaging using wireless MR active markers in simultaneous PET–MR: Phantom and non-human primate studies
Huang C, Ackerman J, Petibon Y, Normandin M, Brady T, Fakhri G, Ouyang J. Motion compensation for brain PET imaging using wireless MR active markers in simultaneous PET–MR: Phantom and non-human primate studies. NeuroImage 2014, 91: 129-137. PMID: 24418501, PMCID: PMC3965607, DOI: 10.1016/j.neuroimage.2013.12.061.Peer-Reviewed Original ResearchConceptsMotion correctionWireless markersList-mode reconstructionReconstructed PET imagesMotion correction techniqueObserver signal-to-noise ratioSimultaneous PET-MRMotion artifactsPET phantomPET contrastPET reconstructionBrain PET imagingPET imagingPhantomBrain PETPET-MRIndependent noise realizationsAccurate quantitative valuesHead motionNoise realizationsPET dataSignal-to-noise ratioStatic referenceBrain PET scansActivation markers