2020
A general-purpose Monte Carlo particle transport code based on inverse transform sampling for radiotherapy dose calculation
Liang Y, Muhammad W, Hart GR, Nartowt BJ, Chen ZJ, Yu JB, Roberts KB, Duncan JS, Deng J. A general-purpose Monte Carlo particle transport code based on inverse transform sampling for radiotherapy dose calculation. Scientific Reports 2020, 10: 9808. PMID: 32555530, PMCID: PMC7300009, DOI: 10.1038/s41598-020-66844-7.Peer-Reviewed Original ResearchConceptsPhoton transportBoundary crossing algorithmMonte Carlo particle transport codeMonte Carlo methodTransport simulationsAcceptance-rejection samplingRadiotherapy dose calculationsPhoto-electric effectParticle transport codeEGSnrc simulationsCarlo methodBremsstrahlung eventsInelastic scatteringPair productionRayleigh scatteringThread divergenceMC simulationsTransport codeMC codeHistory schemeParticle transportCrossing algorithmInverseElectron transportSimulation accuracy
2008
Clinical implementation of enhanced dynamic wedges into the Pinnacle treatment planning system: Monte Carlo validation and patient-specific QA
Ahmad M, Deng J, Lund MW, Chen Z, Kimmett J, Moran MS, Nath R. Clinical implementation of enhanced dynamic wedges into the Pinnacle treatment planning system: Monte Carlo validation and patient-specific QA. Physics In Medicine And Biology 2008, 54: 447-465. PMID: 19098353, DOI: 10.1088/0031-9155/54/2/018.Peer-Reviewed Original Research
2004
Modelling 6 MV photon beams of a stereotactic radiosurgery system for Monte Carlo treatment planning
Deng J, Guerrero T, Ma C, Nath R. Modelling 6 MV photon beams of a stereotactic radiosurgery system for Monte Carlo treatment planning. Physics In Medicine And Biology 2004, 49: 1689-1704. PMID: 15152924, DOI: 10.1088/0031-9155/49/9/007.Peer-Reviewed Original ResearchMeSH KeywordsModels, TheoreticalMonte Carlo MethodParticle AcceleratorsPhantoms, ImagingPhotonsRadiosurgeryRadiotherapy DosageConceptsMV photon beamMonte Carlo treatmentPhoton beamsPhase spaceEGS4/BEAM systemPercent depth dose curvesParticle phase spaceMonte Carlo treatment planningDepth dose curvesFull phase spaceDose calculationsStereotactic radiosurgery systemContaminant electronsCircular planar sourceMonte Carlo systemPrimary photonsMultiple source modelDose profilesSecondary collimatorDose curvesTotal maximum doseDose contributionBeamBeam systemOriginal phase space
2000
Photon beam characterization and modelling for Monte Carlo treatment planning
Deng J, Jiang S, Kapur A, Li J, Pawlicki T, Ma C. Photon beam characterization and modelling for Monte Carlo treatment planning. Physics In Medicine And Biology 2000, 45: 411-427. PMID: 10701512, DOI: 10.1088/0031-9155/45/2/311.Peer-Reviewed Original ResearchMeSH KeywordsModels, TheoreticalMonte Carlo MethodParticle AcceleratorsPhantoms, ImagingPhotonsRadiotherapy Planning, Computer-AssistedSoftwareConceptsOriginal phase spacePhase spaceMonte Carlo calculationsPhoton jawsCarlo calculationsMonte Carlo treatment planningSource-surface distanceVarian Clinac 2100CPhase space filesPrimary collimatorMultiple source modelPhoton beamsPlanar fluenceAngular distributionsMV photon beamClinac 2100CField sizeSource modelBeam characterizationDose distributionHeterogeneous phantomsGood agreementBeam characteristicsFlattening filterEnergy spectrum