2022
Glucose variability increases during minimally invasive procedures in very preterm infants
Galderisi A, Res G, Guiducci S, Savio F, Brigadoi S, Forlani L, Mastrandrea B, Moschino L, Lolli E, Priante E, Trevisanuto D, Baraldi E. Glucose variability increases during minimally invasive procedures in very preterm infants. European Journal Of Pediatrics 2022, 182: 89-94. PMID: 36201017, PMCID: PMC9829573, DOI: 10.1007/s00431-022-04641-2.Peer-Reviewed Original ResearchConceptsVery preterm infantsContinuous glucose monitoringPreterm infantsGlucose variabilityNeonatal stressNappy changeInvasive proceduresMedian glucoseGlucose monitoringNon-invasive procedurePrimary outcomeAbsence of changesHeel prickMean glucoseNeonatal proceduresCare proceduresDay 2InfantsParental presenceGlucose variationCGM dataGlucoseSDNeonatesPrick
2020
1296-P: Omnipod Personalized MPC Algorithm at Target Glucose of 110mg/dl Is Safe in Children Aged 2-12 Years without Increasing Risk of Hypoglycemia
SHERR J, BUCKINGHAM B, FORLENZA G, GALDERISI A, EKHLASPOUR L, WADWA R, ZGORSKI M, KINGMAN R, BERGET C, LEE J, OCONNOR J, DUMAIS B, VIENNEAU T, HUYETT L, LY T. 1296-P: Omnipod Personalized MPC Algorithm at Target Glucose of 110mg/dl Is Safe in Children Aged 2-12 Years without Increasing Risk of Hypoglycemia. Diabetes 2020, 69 DOI: 10.2337/db20-1296-p.Peer-Reviewed Original ResearchDiabetes careGlucose targetsEli LillySerious adverse eventsHigh-fat mealRisk of hypoglycemiaAdvisory PanelType 1 diabetesChildren Aged 2MannKind CorporationHybrid closed-loop systemT1D durationAdverse eventsT1D ExchangeFat mealGlucose managementMean glucosePivotal studiesAged 2Bolus challengeDaily exerciseInvestigational deviceDlPercent timeTarget glucose
2019
215-OR: Safety and Performance of the Omnipod Hybrid Closed-Loop System in Young Children Aged 2-6 Years with Type 1 Diabetes
BUCKINGHAM B, FORLENZA G, SHERR J, GALDERISI A, EKHLASPOUR L, LEE J, OCONNOR J, DUMAIS B, HUYETT L, LAYNE J, LY T. 215-OR: Safety and Performance of the Omnipod Hybrid Closed-Loop System in Young Children Aged 2-6 Years with Type 1 Diabetes. Diabetes 2019, 68 DOI: 10.2337/db19-215-or.Peer-Reviewed Original ResearchDiabetes careMedtronic MiniMedSevere hypoglycemic eventsChildren Aged 2Advisory PanelYoung childrenMin/dAge 4.2Oral carbohydrateHybrid closed-loop systemHypoglycemic eventsGlycemic outcomesMean glucoseAged 2CGM useTherapy phaseInvestigational deviceType 1T1D therapyPercent timeMiniMedLexicon PharmaceuticalsCareUsual routineAdult participants
2016
Randomized Summer Camp Crossover Trial in 5- to 9-Year-Old Children: Outpatient Wearable Artificial Pancreas Is Feasible and Safe
Del Favero S, Boscari F, Messori M, Rabbone I, Bonfanti R, Sabbion A, Iafusco D, Schiaffini R, Visentin R, Calore R, Moncada Y, Galasso S, Galderisi A, Vallone V, Di Palma F, Losiouk E, Lanzola G, Tinti D, Rigamonti A, Marigliano M, Zanfardino A, Rapini N, Avogaro A, Chernavvsky D, Magni L, Cobelli C, Bruttomesso D. Randomized Summer Camp Crossover Trial in 5- to 9-Year-Old Children: Outpatient Wearable Artificial Pancreas Is Feasible and Safe. Diabetes Care 2016, 39: 1180-1185. PMID: 27208335, DOI: 10.2337/dc15-2815.Peer-Reviewed Original ResearchConceptsSensor-augmented pumpCrossover trialMean glucoseArtificial pancreasType 1 diabetesArtificial Pancreas ProjectWearable artificial pancreasAP trialOlder childrenTrialsHypoglycemiaYoung childrenChildrenPancreasOvernight timeSignificant changesGlucoseDaysDiabetesOutpatientsResearch designThreefold reduction