2020
Hand hygiene during COVID-19: Recommendations from the American Contact Dermatitis Society
Rundle CW, Presley CL, Militello M, Barber C, Powell DL, Jacob SE, Atwater AR, Watsky KL, Yu J, Dunnick CA. Hand hygiene during COVID-19: Recommendations from the American Contact Dermatitis Society. Journal Of The American Academy Of Dermatology 2020, 83: 1730-1737. PMID: 32707253, PMCID: PMC7373692, DOI: 10.1016/j.jaad.2020.07.057.Peer-Reviewed Original ResearchMeSH KeywordsAnti-Infective Agents, LocalBetacoronavirusCommunicable Disease ControlCoronavirus InfectionsCOVID-19Dermatitis, ContactDermatitis, OccupationalHand DermatosesHand HygieneHealth PersonnelHumansIrritantsPandemicsPneumonia, ViralPractice Guidelines as TopicSARS-CoV-2SoapsSocieties, MedicalUnited StatesConceptsAmerican Contact Dermatitis SocietyHand hygiene productsHand hygieneAlcohol-based hand sanitizersHealth care workersFrequent hand washingCOVID-19Skin barrier integrityHand dermatitisHygiene productsContact dermatitisIrritant contactGeneral populationCare workersBarrier integrityDisease controlHand washingDermatitisIrritancy potentialHand sanitizerVirus transmissionCOVID-19 pandemicHygieneRecent COVID-19 pandemicMoisturizers
2018
Survey of Patch Test Business Models in the United States by the American Contact Dermatitis Society
Zhu TH, Suresh R, Farahnik B, Jeon C, Warshaw E, Scheinman P, Mowad C, Botto N, Brod B, Taylor JS, Atwater AR, Watsky K, Schalock PC, Machler BC, Helms S, Jacob SE, Murase JE. Survey of Patch Test Business Models in the United States by the American Contact Dermatitis Society. Dermatitis 2018, 29: 85-88. PMID: 29494395, DOI: 10.1097/der.0000000000000355.Peer-Reviewed Original Research
2016
Patch Testing for Evaluation of Hypersensitivity to Implanted Metal Devices
Schalock PC, Crawford G, Nedorost S, Scheinman PL, Atwater AR, Mowad C, Brod B, Ehrlich A, Watsky KL, Sasseville D, Silvestri D, Worobec SM, Elliott JF, Honari G, Powell DL, Taylor J, DeKoven J. Patch Testing for Evaluation of Hypersensitivity to Implanted Metal Devices. Dermatitis 2016, 27: 241-247. PMID: 27649347, DOI: 10.1097/der.0000000000000210.Peer-Reviewed Original ResearchMeSH KeywordsDermatitis, Allergic ContactHumansMetalsPatch TestsProstheses and ImplantsSocieties, MedicalConceptsPatch testingThorough risk-benefit analysisRoutine preoperative evaluationAdverse cutaneous reactionsExpert opinion-based guidelinesAmerican Contact Dermatitis SocietyEvaluation of hypersensitivitySelf-reported historyMetal hypersensitivity reactionsOpinion-based guidelinesRisk-benefit analysisSymptom causalityAdverse eventsClinical factorsPreoperative evaluationCutaneous reactionsHypersensitivity reactionsAssessment of causationPatient managementReaction testingImplanted devicePatientsReasonable evidenceRobust evidenceMetal exposure