2021
Extended Use of the Control-IQ Closed-Loop Control System in Children With Type 1 Diabetes.
Kanapka LG, Wadwa RP, Breton MD, Ruedy KJ, Ekhlaspour L, Forlenza GP, Cengiz E, Schoelwer MJ, Jost E, Carria L, Emory E, Hsu LJ, Weinzimer SA, DeBoer MD, Buckingham BA, Oliveri M, Kollman C, Dokken BB, Cherñavvsky D, Beck RW. Extended Use of the Control-IQ Closed-Loop Control System in Children With Type 1 Diabetes. Diabetes Care 2021, 44: 473-478. PMID: 33355258, PMCID: PMC7818334, DOI: 10.2337/dc20-1729.Peer-Reviewed Original ResearchConceptsType 1 diabetesChildren 6Sensor-Augmented Pump TherapyWeeks of useDiabetic ketoacidosisDays of useGlycemic controlSAP groupSevere hypoglycemiaPump therapyClinical trialsPercentage of timeCLC groupMean TIRDiabetesFurther evaluationCohortRCTsDlWeeksChildrenDaysExtended useParticipantsKetoacidosis
2018
Predictive Low-Glucose Suspend Reduces Hypoglycemia in Adults, Adolescents, and Children With Type 1 Diabetes in an At-Home Randomized Crossover Study: Results of the PROLOG Trial
Forlenza GP, Li Z, Buckingham BA, Pinsker JE, Cengiz E, Wadwa RP, Ekhlaspour L, Church MM, Weinzimer SA, Jost E, Marcal T, Andre C, Carria L, Swanson V, Lum JW, Kollman C, Woodall W, Beck RW. Predictive Low-Glucose Suspend Reduces Hypoglycemia in Adults, Adolescents, and Children With Type 1 Diabetes in an At-Home Randomized Crossover Study: Results of the PROLOG Trial. Diabetes Care 2018, 41: dc180771. PMID: 30089663, DOI: 10.2337/dc18-0771.Peer-Reviewed Original ResearchConceptsType 1 diabetesSAP armPredictive low glucose suspendSensor-Augmented Pump TherapyNew insulin delivery systemsRandomized Crossover StudySevere hypoglycemic eventsGlucose concentrationMin/dayMean glucose concentrationLow glucose suspendBasal-IQRebound hyperglycemiaSlim X2Glycemic controlPrimary outcomeCrossover studyMedian timeCrossover trialHypoglycemic eventsPump therapyInsulin delivery systemsPercentage of timeHypoglycemiaDiabetes
2016
Continuous Glucose Monitoring: A Consensus Conference of the American Association of Clinical Endocrinologists and American College of Endocrinology
Fonseca VA, Grunberger G, Anhalt H, Bailey TS, Blevins T, Garg SK, Handelsman Y, Hirsch IB, Orzeck EA, Roberts VL, Tamborlane W, Committee O. Continuous Glucose Monitoring: A Consensus Conference of the American Association of Clinical Endocrinologists and American College of Endocrinology. Endocrine Practice 2016, 22: 1008-1021. PMID: 27214060, DOI: 10.4158/ep161392.cs.Peer-Reviewed Original ResearchConceptsContinuous glucose monitoringAmerican CollegeCGM coverageClinical EndocrinologistsBenefits of CGMSensor-Augmented Pump TherapyClinical Endocrinologists ACEHealthcare resource utilizationIntensive insulin therapyHealth-related qualityType 1 diabetesManagement of diabetesAmerican AssociationAvailable CGM dataReal-world analysisChronic complicationsInsulin therapyDiabetes typeGlycemic controlPump therapyPatient understandingConsensus conferenceDiabetes managementHealth outcomesType 2Automated hybrid closed‐loop control with a proportional‐integral‐derivative based system in adolescents and adults with type 1 diabetes: individualizing settings for optimal performance
Ly TT, Weinzimer SA, Maahs DM, Sherr JL, Roy A, Grosman B, Cantwell M, Kurtz N, Carria L, Messer L, von Eyben R, Buckingham BA. Automated hybrid closed‐loop control with a proportional‐integral‐derivative based system in adolescents and adults with type 1 diabetes: individualizing settings for optimal performance. Pediatric Diabetes 2016, 18: 348-355. PMID: 27191182, DOI: 10.1111/pedi.12399.Peer-Reviewed Original ResearchMeSH KeywordsActivities of Daily LivingAdolescentAdolescent BehaviorAdultAlgorithmsBlood GlucoseBlood Glucose Self-MonitoringCalibrationCohort StudiesDiabetes Mellitus, Type 1Drug Dosage CalculationsDrug MonitoringGlucoseHumansHyperglycemiaHypoglycemiaHypoglycemic AgentsInsulinPancreas, ArtificialPrecision MedicineSubcutaneous TissueYoung AdultConceptsType 1 diabetesAdolescent cohortAdult cohortHybrid closed-loop systemPump therapyPercentage of timeGlucose valuesSensor-Augmented Pump TherapyOverall glucose controlInsulin pump therapyOverall mean percentageDose insulinGlucose controlPreliminary safetyInsulin delivery systemsInitial cohortHybrid closed-loop controlClinical practiceSecond cohortCohortMean percentageTarget rangeOverall percentageDiabetesAdults
2013
Effectiveness of Early Intensive Therapy on β-Cell Preservation in Type 1 Diabetes
Buckingham B, Beck RW, Ruedy KJ, Cheng P, Kollman C, Weinzimer SA, DiMeglio LA, Bremer AA, Slover R, Tamborlane WV. Effectiveness of Early Intensive Therapy on β-Cell Preservation in Type 1 Diabetes. Diabetes Care 2013, 36: 4030-4035. PMID: 24130350, PMCID: PMC3836135, DOI: 10.2337/dc13-1074.Peer-Reviewed Original ResearchConceptsUsual care groupC-peptide concentrationsType 1 diabetesΒ-cell functionHybrid closed-loop controlSAP therapyPump therapyContinuous glucose monitorNew-onset type 1 diabetesPeak C-peptide concentrationMixed-meal tolerance testSensor-Augmented Pump TherapyEarly intensive therapyΒ-cell preservationUsual care participantsDays of diagnosisC-peptide areaMultiple daily injectionsInsulin pump therapyDays/weekMean glucose concentrationMedian durationIntensive therapyPrimary outcomeDaily injectionsThe Effects of Inpatient Hybrid Closed-Loop Therapy Initiated Within 1 Week of Type 1 Diabetes DiagnosisDiabetes Research in Children Network (DirecNet) and Type 1 Diabetes TrialNet Study Groups*
Buckingham B, Beck R, Ruedy K, Cheng P, Kollman C, Weinzimer S, DiMeglio L, Bremer A, Slover R, Cantwell M. The Effects of Inpatient Hybrid Closed-Loop Therapy Initiated Within 1 Week of Type 1 Diabetes DiagnosisDiabetes Research in Children Network (DirecNet) and Type 1 Diabetes TrialNet Study Groups*. Diabetes Technology & Therapeutics 2013, 15: 401-408. PMID: 23570538, PMCID: PMC3643224, DOI: 10.1089/dia.2013.0002.Peer-Reviewed Original ResearchConceptsType 1 diabetesMean glucose concentrationHybrid closed-loop controlMedian percentageHybrid closed-loop therapyType 1Sensor-Augmented Pump TherapyPositive pancreatic autoantibodiesTrialNet Study GroupDays of diagnosisNormal glycemic controlΒ-cell functionGlucose concentrationClosed-loop therapyPancreatic autoantibodiesGlycemic controlSAP therapyPump therapyStudy groupGlucose levelsGlucose toxicityDay 2Day 3Glucose valuesTherapy
2011
Sensor-Augmented Pump Therapy for A1C Reduction (STAR 3) Study Results from the 6-month continuation phase
Bergenstal RM, Tamborlane WV, Ahmann A, Buse JB, Dailey G, Davis SN, Joyce C, Perkins BA, Welsh JB, Willi SM, Wood MA. Sensor-Augmented Pump Therapy for A1C Reduction (STAR 3) Study Results from the 6-month continuation phase. Diabetes Care 2011, 34: 2403-2405. PMID: 21933908, PMCID: PMC3198292, DOI: 10.2337/dc11-1248.Peer-Reviewed Original ResearchEffectiveness of sensor‐augmented pump therapy in children and adolescents with type 1 diabetes in the STAR 3 study
Slover RH, Welsh JB, Criego A, Weinzimer SA, Willi SM, Wood MA, Tamborlane WV. Effectiveness of sensor‐augmented pump therapy in children and adolescents with type 1 diabetes in the STAR 3 study. Pediatric Diabetes 2011, 13: 6-11. PMID: 21722284, DOI: 10.1111/j.1399-5448.2011.00793.x.Peer-Reviewed Original ResearchConceptsType 1 diabetesSensor-Augmented Pump TherapyA1C valuesSAP groupMDI groupPump therapyA1C targetsSAP therapyHyperglycemic excursionsMultiple daily injection therapyBaseline A1C valuesRisk of hypoglycemiaA1C reductionInjection therapyPediatric patientsGlycemic excursionsGlucose variabilityMDI therapyGlycemic variabilityLower AUC valuesTreatment groupsTherapyCGM studiesDiabetesAUC values
2010
Effectiveness of Sensor-Augmented Insulin-Pump Therapy in Type 1 Diabetes
Bergenstal RM, Tamborlane WV, Ahmann A, Buse JB, Dailey G, Davis SN, Joyce C, Peoples T, Perkins BA, Welsh JB, Willi SM, Wood MA. Effectiveness of Sensor-Augmented Insulin-Pump Therapy in Type 1 Diabetes. New England Journal Of Medicine 2010, 363: 311-320. PMID: 20587585, DOI: 10.1056/nejmoa1002853.Peer-Reviewed Original ResearchConceptsInjection therapy groupPump-therapy groupSensor-Augmented Pump TherapyGlycated hemoglobin levelsHemoglobin levelsType 1 diabetesPump therapyBaseline glycated hemoglobin levelMultiple daily insulin injectionsType 1 diabetes mellitusGlycated haemoglobin targetPrimary end pointProportion of patientsDaily insulin injectionsSignificant weight gainRecombinant insulin analogueHemoglobin targetsInjection therapyDiabetes mellitusSevere hypoglycemiaInsulin injectionsClinical teamInsulin analoguesEnd pointTherapySTAR 3 Randomized Controlled Trial to Compare Sensor-Augmented Insulin Pump Therapy with Multiple Daily Injections in the Treatment of Type 1 Diabetes: Research Design, Methods, and Baseline Characteristics of Enrolled Subjects
Davis SN, Horton ES, Battelino T, Rubin RR, Schulman KA, Tamborlane WV. STAR 3 Randomized Controlled Trial to Compare Sensor-Augmented Insulin Pump Therapy with Multiple Daily Injections in the Treatment of Type 1 Diabetes: Research Design, Methods, and Baseline Characteristics of Enrolled Subjects. Diabetes Technology & Therapeutics 2010, 12: 249-255. PMID: 20210562, PMCID: PMC2883476, DOI: 10.1089/dia.2009.0145.Peer-Reviewed Original ResearchConceptsMultiple daily injectionsContinuous subcutaneous insulin infusionType 1 diabetesPercentage of subjectsPump therapyEnd pointBaseline characteristicsDaily injectionsKey safety end pointsType 1Sensor-Augmented Pump TherapyReal-time continuous glucose monitoringSensor-Augmented Insulin Pump TherapyNormal glycemic rangeTertiary end pointPrimary end pointSafety end pointSecondary end pointsInsulin pump therapySubcutaneous insulin infusionYears of treatmentContinuous glucose monitoringMDI cohortSevere hypoglycemiaClinical outcomes
This site is protected by hCaptcha and its Privacy Policy and Terms of Service apply