Albert Sinusas, MD
Research & Publications
Biography
News
Research Summary
My research is directed at development of noninvasive imaging approaches for the assessment of myocardial viability, angiogenesis, and post–infarction remodeling. This translational research employs the 3–D modalities of SPECT, PET, echocardiography and MR imaging for assessment of regional myocardial perfusion, function and metabolism, in an animal physiology laboratory, employing large and small animal models of myocardial ischemia and infarction, and peripheral arterial disease. My laboratory is currently focused on targeted molecular imaging, developing non–invasive nuclear imaging strategies for identifying the hypoxic stimulus for angiogenesis, and targeted imaging of selected integrins previously established to modulate the angiogenic process, and evaluation of the role of matrix metalloproteinases on post–infarction remodeling. The investigation of these biological processes involves, in vitro cellular and whole heart preparations, as well as ex vivo and in vivo imaging in both small and large animal models, using dedicated high–resolution and real–time 3D ultrasound imaging, hybrid SPECT–CT and PET–CT imaging, cardiac MR imaging, and fluorescent imaging systems.
Specialized Terms: Advanced cardiovascular and molecular imaging
Coauthors
Research Interests
Cardiology; Cardiovascular System; Echocardiography; Magnetic Resonance Imaging; Tomography, Emission-Computed, Single-Photon; Positron-Emission Tomography; Myocardial Perfusion Imaging; Translational Research, Biomedical
Selected Publications
- Multiaxial pressure-strain analysis of regional myocardial work in the setting of graded coronary stenoses and dobutamine stressStendahl J, Liu Z, Boutagy N, Parajuli N, Lu A, Alkhalil I, Lin B, Duncan J, Sinusas A. Multiaxial pressure-strain analysis of regional myocardial work in the setting of graded coronary stenoses and dobutamine stress AJP Heart And Circulatory Physiology 2023 PMID: 37417870, DOI: 10.1152/ajpheart.00735.2022.
- Improvement in Cardiac Function and Regional LV Strain Following Intramyocardial Injection of a Hydrogel Early Post Myocardial Infarction in a Porcine ModelAvendaño R, Midgett D, Melvinsdottir I, Thorn S, Uman S, Pickell Z, Lee S, Liu Z, Mamarian M, Duncan J, Spinale F, Burdick J, Sinusas A. Improvement in Cardiac Function and Regional LV Strain Following Intramyocardial Injection of a Hydrogel Early Post Myocardial Infarction in a Porcine Model Journal Of Applied Physiology 2023 PMID: 37318987, DOI: 10.1152/japplphysiol.00342.2022.
- The Potential Role of PET in the Management of Peripheral Artery DiseaseAlashi A, Vermillion B, Sinusas A. The Potential Role of PET in the Management of Peripheral Artery Disease Current Cardiology Reports 2023, 1-9. PMID: 37314651, DOI: 10.1007/s11886-023-01904-8.
- Quantitative cardiovascular magnetic resonance findings and clinical risk factors predict cardiovascular outcomes in breast cancer patientsKwan J, Arbune A, Henry M, Hu R, Wei W, Nguyen V, Lee S, Lopez-Mattei J, Guha A, Huber S, Bader A, Meadows J, Sinusas A, Mojibian H, Peters D, Lustberg M, Hull S, Baldassarre L. Quantitative cardiovascular magnetic resonance findings and clinical risk factors predict cardiovascular outcomes in breast cancer patients PLOS ONE 2023, 18: e0286364. PMID: 37252927, PMCID: PMC10228774, DOI: 10.1371/journal.pone.0286364.
- 0488 The Relationship between Myocardial Blood Flow and Diastolic Function in a Clinical Population with Obstructive Sleep ApneaAneni E, Saeed G, Thorn S, Miller E, Sinusas A, Yaggi H. 0488 The Relationship between Myocardial Blood Flow and Diastolic Function in a Clinical Population with Obstructive Sleep Apnea Sleep 2023, 46: a217-a217. DOI: 10.1093/sleep/zsad077.0488.
- DuSFE: Dual-Channel Squeeze-Fusion-Excitation co-attention for cross-modality registration of cardiac SPECT and CTChen X, Zhou B, Xie H, Guo X, Zhang J, Duncan J, Miller E, Sinusas A, Onofrey J, Liu C. DuSFE: Dual-Channel Squeeze-Fusion-Excitation co-attention for cross-modality registration of cardiac SPECT and CT Medical Image Analysis 2023, 88: 102840. PMID: 37216735, DOI: 10.1016/j.media.2023.102840.
- Segmentation-Free PVC for Cardiac SPECT Using a Densely-Connected Multi-Dimensional Dynamic NetworkXie H, Liu Z, Shi L, Greco K, Chen X, Zhou B, Feher A, Stendahl J, Boutagy N, Kyriakides T, Wang G, Sinusas A, Liu C. Segmentation-Free PVC for Cardiac SPECT Using a Densely-Connected Multi-Dimensional Dynamic Network IEEE Transactions On Medical Imaging 2023, 42: 1325-1336. PMID: 36459599, PMCID: PMC10204821, DOI: 10.1109/tmi.2022.3226604.
- Time and event-specific deep learning for personalized risk assessment after cardiac perfusion imagingPieszko K, Shanbhag A, Singh A, Hauser M, Miller R, Liang J, Motwani M, Kwieciński J, Sharir T, Einstein A, Fish M, Ruddy T, Kaufmann P, Sinusas A, Miller E, Bateman T, Dorbala S, Di Carli M, Berman D, Dey D, Slomka P. Time and event-specific deep learning for personalized risk assessment after cardiac perfusion imaging Npj Digital Medicine 2023, 6: 78. PMID: 37127660, PMCID: PMC10151323, DOI: 10.1038/s41746-023-00806-x.
- Comprehensive Multimodality Imaging of Congenitally Corrected Transposition of the Great Arteries Incidentally Found to Have Coronary Ischemia.Sasse A, Feher A, Thorn S, Fahey J, Keeshan B, Sinusas A, Mojibian H, Steele J. Comprehensive Multimodality Imaging of Congenitally Corrected Transposition of the Great Arteries Incidentally Found to Have Coronary Ischemia. Circulation Cardiovascular Imaging 2023, e015158. PMID: 37092334, DOI: 10.1161/circimaging.122.015158.
- Unsupervised learning to characterize patients with known coronary artery disease undergoing myocardial perfusion imagingWilliams M, Bednarski B, Pieszko K, Miller R, Kwiecinski J, Shanbhag A, Liang J, Huang C, Sharir T, Dorbala S, Di Carli M, Einstein A, Sinusas A, Miller E, Bateman T, Fish M, Ruddy T, Acampa W, Hauser M, Kaufmann P, Dey D, Berman D, Slomka P. Unsupervised learning to characterize patients with known coronary artery disease undergoing myocardial perfusion imaging European Journal Of Nuclear Medicine And Molecular Imaging 2023, 1-13. PMID: 37067586, DOI: 10.1007/s00259-023-06218-z.
- Impaired left-ventricular global longitudinal strain by feature-tracking cardiac MRI predicts mortality in systemic sclerosisFeher A, Miller E, Peters D, Mojibian H, Sinusas A, Hinchcliff M, Baldassarre L. Impaired left-ventricular global longitudinal strain by feature-tracking cardiac MRI predicts mortality in systemic sclerosis Rheumatology International 2023, 43: 849-858. PMID: 36894756, DOI: 10.1007/s00296-023-05294-6.
- RB-82 PET DERIVED REGIONAL MYOCARDIAL BLOOD FLOW IS ASSOCIATED WITH ALL-CAUSE MORTALITY IN PATIENTS PRESENTING WITH ACUTE CHEST PAINTrejo-Paredes C, Hu J, Shah S, Liu Y, Smolderen K, Hurtado C, Sinusas A, Miller E. RB-82 PET DERIVED REGIONAL MYOCARDIAL BLOOD FLOW IS ASSOCIATED WITH ALL-CAUSE MORTALITY IN PATIENTS PRESENTING WITH ACUTE CHEST PAIN Journal Of The American College Of Cardiology 2023, 81: 1502. DOI: 10.1016/s0735-1097(23)01946-0.
- REST/STRESS DYNAMIC COMPUTED TOMOGRAPHY PERFUSION FOR EVALUATING PERIPHERAL ARTERIAL DISEASE: VALIDATION IN RABBIT MODEL OF HINDLIMB ISCHEMIAAlashi A, Vermillion B, Burns R, Lee S, Bingham B, Guerrera N, Papademetris X, Thorn S, Sinusas A. REST/STRESS DYNAMIC COMPUTED TOMOGRAPHY PERFUSION FOR EVALUATING PERIPHERAL ARTERIAL DISEASE: VALIDATION IN RABBIT MODEL OF HINDLIMB ISCHEMIA Journal Of The American College Of Cardiology 2023, 81: 1372. DOI: 10.1016/s0735-1097(23)01816-8.
- CORONARY ARTERY CALCIFICATIONS ARE A BETTER PREDICTOR OF CARDIOVASCULAR OUTCOMES THAN ISCHEMIC ECG CHANGES IN PATIENTS WITH NORMAL PERFUSION ON EXERCISE SPECTShi T, Kokkinidis D, Agarwal R, Liu Y, Sinusas A, Miller E, Feher A. CORONARY ARTERY CALCIFICATIONS ARE A BETTER PREDICTOR OF CARDIOVASCULAR OUTCOMES THAN ISCHEMIC ECG CHANGES IN PATIENTS WITH NORMAL PERFUSION ON EXERCISE SPECT Journal Of The American College Of Cardiology 2023, 81: 1498. DOI: 10.1016/s0735-1097(23)01942-3.
- IN PATIENTS UNDERGOING NUCLEAR MYOCARDIAL PERFUSION IMAGING, RHEUMATOID ARTHRITIS IS ASSOCIATED WITH INCREASED RISK OF ADVERSE CARDIOVASCULAR EVENTS INDEPENDENT OF MYOCARDIAL ISCHEMIAPires J, Oikonomou E, Agarwal R, Liu Y, miller E, Sinusas A, Feher A. IN PATIENTS UNDERGOING NUCLEAR MYOCARDIAL PERFUSION IMAGING, RHEUMATOID ARTHRITIS IS ASSOCIATED WITH INCREASED RISK OF ADVERSE CARDIOVASCULAR EVENTS INDEPENDENT OF MYOCARDIAL ISCHEMIA Journal Of The American College Of Cardiology 2023, 81: 1467. DOI: 10.1016/s0735-1097(23)01911-3.
- ASSOCIATION OF RB-82 PET DERIVED REGIONAL MYOCARDIAL BLOOD FLOW TO SEVERITY OF ANGIOGRAPHIC CORONARY ARTERY STENOSIS IN PATIENTS PRESENTING WITH ACUTE CHEST PAINHu J, Trejo-Paredes C, Shah S, Liu Y, Smolderen K, Hurtado C, Sinusas A, Miller E, Kattan C. ASSOCIATION OF RB-82 PET DERIVED REGIONAL MYOCARDIAL BLOOD FLOW TO SEVERITY OF ANGIOGRAPHIC CORONARY ARTERY STENOSIS IN PATIENTS PRESENTING WITH ACUTE CHEST PAIN Journal Of The American College Of Cardiology 2023, 81: 1409. DOI: 10.1016/s0735-1097(23)01853-3.
- The Association Between Obstructive Sleep Apnea and Abnormal 82Rubidium Cardiac PET Perfusion Myocardial Flow ReserveAneni E, Thorn S, Feher A, Hong Chen J, Sinusas A, Yaggi H, Miller E. The Association Between Obstructive Sleep Apnea and Abnormal 82Rubidium Cardiac PET Perfusion Myocardial Flow Reserve JACC Cardiovascular Imaging 2023, 16: 856-858. PMID: 36881426, DOI: 10.1016/j.jcmg.2022.11.024.
- Correction to: Integration of coronary artery calcium scoring from CT attenuation scans by machine learning improves prediction of adverse cardiovascular events in patients undergoing SPECT/CT myocardial perfusion imagingFeher A, Pieszko K, Miller R, Lemley M, Shanbhag A, Huang C, Miras L, Liu Y, Sinusas A, Miller E, Slomka P. Correction to: Integration of coronary artery calcium scoring from CT attenuation scans by machine learning improves prediction of adverse cardiovascular events in patients undergoing SPECT/CT myocardial perfusion imaging Journal Of Nuclear Cardiology 2023, 30: 860-863. PMID: 36598750, DOI: 10.1007/s12350-022-03196-x.
- Thrombus Imaging Following Myocardial Infarction Does Molecular Imaging Offer an Advantage? ∗Sinusas A. Thrombus Imaging Following Myocardial Infarction Does Molecular Imaging Offer an Advantage? ∗ JACC Cardiovascular Imaging 2022, 16: 833-836. PMID: 36648044, DOI: 10.1016/j.jcmg.2022.10.015.
- Co-attention spatial transformer network for unsupervised motion tracking and cardiac strain analysis in 3D echocardiographyAhn S, Ta K, Thorn S, Onofrey J, Melvinsdottir I, Lee S, Langdon J, Sinusas A, Duncan J. Co-attention spatial transformer network for unsupervised motion tracking and cardiac strain analysis in 3D echocardiography Medical Image Analysis 2022, 84: 102711. PMID: 36525845, PMCID: PMC9812938, DOI: 10.1016/j.media.2022.102711.
- Obstructive Sleep Apnea Severity is Associated with Abnormal Myocardial 82Rubidium PET Blood Flow ReserveAneni E, Chen J, Thorn S, Miller E, Sinusas A, Yaggi H. Obstructive Sleep Apnea Severity is Associated with Abnormal Myocardial 82Rubidium PET Blood Flow Reserve Sleep Medicine 2022, 100: s261. DOI: 10.1016/j.sleep.2022.05.703.
- Thrombus Imaging Following Myocardial Infarction Does Molecular Imaging Offer an Advantage? ∗Sinusas A. Thrombus Imaging Following Myocardial Infarction Does Molecular Imaging Offer an Advantage? ∗ JACC Cardiovascular Imaging 2022 DOI: 10.1016/j.jcmg.2022.10.015.
- Abstract 14839: Clinical, Polysomnographic and Echocardiographic Correlates of Excessive Daytime SleepinessSaeed G, Aneni E, Otite F, Thorn S, Miller E, Sinusas A, Yaggi H. Abstract 14839: Clinical, Polysomnographic and Echocardiographic Correlates of Excessive Daytime Sleepiness Circulation 2022, 146: a14839-a14839. DOI: 10.1161/circ.146.suppl_1.14839.
- Abstract 13798: Obstructive Sleep Apnea Severity and Abnormal Right Ventricular Flow Reserve in Adult OSA Patients Who Received Rubidium-82 Cardiac PET Perfusion ImagingAneni E, Miller E, Saeed G, deKemp R, KLEIN R, Beanlands R, Yaggi H, Sinusas A, Thorn S. Abstract 13798: Obstructive Sleep Apnea Severity and Abnormal Right Ventricular Flow Reserve in Adult OSA Patients Who Received Rubidium-82 Cardiac PET Perfusion Imaging Circulation 2022, 146: a13798-a13798. DOI: 10.1161/circ.146.suppl_1.13798.
- Quantification of intramyocardial blood volume using 99mTc-RBC SPECT/CT: a pilot human studyYousefi H, Shi L, Soufer A, Tsatkin V, Bruni W, Avendano R, Greco K, McMahon D, Thorn S, Miller E, Sinusas A, Liu C. Quantification of intramyocardial blood volume using 99mTc-RBC SPECT/CT: a pilot human study Journal Of Nuclear Cardiology 2022, 30: 292-297. PMID: 36319815, DOI: 10.1007/s12350-022-03123-0.
- Dual-Branch Squeeze-Fusion-Excitation Module for Cross-Modality Registration of Cardiac SPECT and CTChen X, Zhou B, Xie H, Guo X, Zhang J, Sinusas A, Onofrey J, Liu C. Dual-Branch Squeeze-Fusion-Excitation Module for Cross-Modality Registration of Cardiac SPECT and CT 2022, 13436: 46-55. DOI: 10.1007/978-3-031-16446-0_5.
- 445 Three-dimensional High Resolution Lagrangian Strain Analysis In The Right Ventricle Using Cinect In A Porcine ModelSavarimuthu S, Midgett D, Thorn S, Ahn S, Avendano R, Melvinsdottir I, Duncan J, Papademetris X, Sinusas A. 445 Three-dimensional High Resolution Lagrangian Strain Analysis In The Right Ventricle Using Cinect In A Porcine Model Journal Of Cardiovascular Computed Tomography 2022, 16: s21. DOI: 10.1016/j.jcct.2022.06.050.
- 430 CT Imaging Of Gadolinium And Iodine Doped Bioresorbable Vascular ScaffoldsStendahl J, Scanlon J, Lee S, Vermillion B, Alashi A, Politis J, Hoerner M, Sinusas A. 430 CT Imaging Of Gadolinium And Iodine Doped Bioresorbable Vascular Scaffolds Journal Of Cardiovascular Computed Tomography 2022, 16: s14-s15. DOI: 10.1016/j.jcct.2022.06.035.
- Deep-Learning-Based Few-Angle Cardiac SPECT Reconstruction Using TransformerXie H, Thorn S, Liu Y, Lee S, Liu Z, Wang G, Sinusas A, Liu C. Deep-Learning-Based Few-Angle Cardiac SPECT Reconstruction Using Transformer IEEE Transactions On Radiation And Plasma Medical Sciences 2022, 7: 33-40. DOI: 10.1109/trpms.2022.3187595.
- CineCT platform for in vivo and ex vivo measurement of 3D high resolution Lagrangian strains in the left ventricle following myocardial infarction and intramyocardial delivery of theranostic hydrogelMidgett D, Thorn S, Ahn S, Uman S, Avendano R, Melvinsdottir I, Lysyy T, Kim J, Duncan J, Humphrey J, Papademetris X, Burdick J, Sinusas A. CineCT platform for in vivo and ex vivo measurement of 3D high resolution Lagrangian strains in the left ventricle following myocardial infarction and intramyocardial delivery of theranostic hydrogel Journal Of Molecular And Cellular Cardiology 2022, 166: 74-90. PMID: 35227737, PMCID: PMC9035115, DOI: 10.1016/j.yjmcc.2022.02.004.
- Abstract 13133: Heterogeneous Uptake of [99mTc]microspheres and 201Tl in Skeletal Muscles in Porcine Model of Hindlimb IschemiaLee S, de Rubio Cruz P, Thorn S, Liu Z, hawley C, Mamarian M, Turlejski T, Meng L, Liu C, Sinusas A. Abstract 13133: Heterogeneous Uptake of [99mTc]microspheres and 201Tl in Skeletal Muscles in Porcine Model of Hindlimb Ischemia Circulation 2021, 144: a13133-a13133. DOI: 10.1161/circ.144.suppl_1.13133.
- Abstract 14327: Intramyocardial Delivery of an Imageable Theranostic Hydrogel Post Myocardial Infarction Alters Regional Strain and Reduces Remodeling in Chronic Porcine ModelMelvinsdottir I, Midgett D, Lee S, Uman S, Kim J, Avendano R, Thorn S, Lysyy T, Arnarsson K, Humphrey J, Duncan J, Burdick J, Sinusas A. Abstract 14327: Intramyocardial Delivery of an Imageable Theranostic Hydrogel Post Myocardial Infarction Alters Regional Strain and Reduces Remodeling in Chronic Porcine Model Circulation 2021, 144: a14327-a14327. DOI: 10.1161/circ.144.suppl_1.14327.
- Novel SPECT and PET Tracers and Myocardial ImagingMelvinsdottir I, Avendaño R, Sinusas A. Novel SPECT and PET Tracers and Myocardial Imaging 2021, 189-228. DOI: 10.1007/978-3-030-83167-7_11.
- Impact of age, sex, and cardiac size on the diagnostic performance of myocardial perfusion single-photon emission computed tomography: insights from the REFINE SPECT registryRandazzo M, Elias P, Poterucha T, Sharir T, Fish M, Ruddy T, Kaufmann P, Sinusas A, Miller E, Bateman T, Dorbala S, Di Carli M, Berman D, Slomka P, Einstein A. Impact of age, sex, and cardiac size on the diagnostic performance of myocardial perfusion single-photon emission computed tomography: insights from the REFINE SPECT registry European Heart Journal 2021, 42: ehab724.0254. DOI: 10.1093/eurheartj/ehab724.0254.
- In-vivo Measurement Of 3d Left Ventricular Myocardial Strain Using CineCT Imaging Post Myocardial Infarction And Following Intramyocardial Delivery Of Theranostic HydrogelMidgett D, Thorn S, Awn S, Uman S, Lysyy T, Kim J, Duncan J, Humphrey J, Papademetris X, Burdick J, Sinusas A. In-vivo Measurement Of 3d Left Ventricular Myocardial Strain Using CineCT Imaging Post Myocardial Infarction And Following Intramyocardial Delivery Of Theranostic Hydrogel Journal Of Cardiovascular Computed Tomography 2021, 15: s26-s27. DOI: 10.1016/j.jcct.2021.06.215.
- Radiotracer imaging of peripheral vascular diseaseStacy M, Zhou W, Sinusas A. Radiotracer imaging of peripheral vascular disease Chinese Journal Of Nuclear Medicine And Molecular Imaging 2021, 41: 378-384. DOI: 10.3760/cma.j.cn321828-20210508-00155.
- 57884 Fast strain-encoded cardiac magnetic resonance detects immune checkpoint inhibitor associated cardiotoxicityCuomo J, Ragheb E, Feher A, Kwan J, Huber S, Mojibian H, Peters D, Sinusas A, Baldassarre L. 57884 Fast strain-encoded cardiac magnetic resonance detects immune checkpoint inhibitor associated cardiotoxicity Journal Of Clinical And Translational Science 2021, 5: 141-142. PMCID: PMC8827987, DOI: 10.1017/cts.2021.761.
- Sex Differences in Arteriovenous Fistula-induced Cardiac Hypertrophy Lead to Similar Cardioprotective AdaptationLee S, Thorn S, Guerrera N, Gonzalez L, Taniguchi R, Langford J, Sinusas A, Dardik A. Sex Differences in Arteriovenous Fistula-induced Cardiac Hypertrophy Lead to Similar Cardioprotective Adaptation JVS Vascular Science 2021, 2: 276-277. DOI: 10.1016/j.jvssci.2021.09.007.
- Coronary Computed Tomography Angiography Compared With Single Photon Emission Computed Tomography Myocardial Perfusion Imaging as a Guide to Optimal Medical Therapy in Patients Presenting With Stable Angina: The RESCUE TrialStillman A, Gatsonis C, Lima J, Liu T, Snyder B, Cormack J, Malholtra V, Schnall M, Udelson J, Hoffmann U, Woodard P, Kim M, Hegde V, Kenny, Afaq M, Clouse M, Malhotra V, Cole, Al‐Khori F, Scherer M, Rothenberg F, Kirsch J, Shah A, Quyyumi A, Engberding N, Becker C, Li D, Pantelic M, Duerinckx A, Martin, Schrank J, Zachariah, Jacob R, Borges A, Roberge E, Truong Q, Edelman R, Akers S, Marsh K, Kemp, Reingold J, Chilakapati V, Osborne J, Lui K, Gomes A, Bajpai A, del Rio J, Singh, Thompson B, Rivard A, Jha S, Mavromatis K, Woodard P, Sinusas A. Coronary Computed Tomography Angiography Compared With Single Photon Emission Computed Tomography Myocardial Perfusion Imaging as a Guide to Optimal Medical Therapy in Patients Presenting With Stable Angina: The RESCUE Trial Journal Of The American Heart Association 2020, 9: e017993. PMID: 33283579, PMCID: PMC7955393, DOI: 10.1161/jaha.120.017993.
- Abstract 16617: Multimodality Imaging Approach in Delivery and Tracking of a Novel Imageable Hydrogel in a Chronic Porcine Infarct ModelMelvinsdottir I, Lee S, Avendano R, Midgett D, Liu Y, Thorn S, hawley C, Mamarian M, Uman S, Humphrey J, Duncan J, Burdick J, Sinusas A. Abstract 16617: Multimodality Imaging Approach in Delivery and Tracking of a Novel Imageable Hydrogel in a Chronic Porcine Infarct Model Circulation 2020, 142 DOI: 10.1161/circ.142.suppl_3.16617.
- Cardiac CT Approach To Guide Delivery And Evaluate The Impact Of A Novel Imageable Theranostic Hydrogel Post Myocardial Infarction In An Acute Porcine ModelAvendaño R, Midgett D, Melvinsdottir I, Lee S, Hawley C, Mamarian M, Uman S, Thorn S, Humphrey J, Duncan J, Burdick J, Sinusas A. Cardiac CT Approach To Guide Delivery And Evaluate The Impact Of A Novel Imageable Theranostic Hydrogel Post Myocardial Infarction In An Acute Porcine Model Journal Of Cardiovascular Computed Tomography 2020, 14: s26. DOI: 10.1016/j.jcct.2020.06.029.
- Application Of Cine CT Imaging For Evaluation Of Biomechanics Of The Left Ventricle Post Myocardial Infarction And Following Intramyocardial Delivery Of Imageable HydrogelMidgett D, Sinusas A, Melvinsdottir I, Avendano R, Lee S. Application Of Cine CT Imaging For Evaluation Of Biomechanics Of The Left Ventricle Post Myocardial Infarction And Following Intramyocardial Delivery Of Imageable Hydrogel Journal Of Cardiovascular Computed Tomography 2020, 14: s28-s29. DOI: 10.1016/j.jcct.2020.06.035.
- Multimodality Imaging Approach To Evaluate The Delivery And Impact Of A Novel Imageable Theranostic Hydrogel Post Myocardial Infarction In A Chronic Porcine ModelMelvinsdottir I, Lee S, Avendano R, Midgett D, Thorn S, Liu Y, Uman S, Humphrey J, Duncan J, Burdick J, Sinusas A. Multimodality Imaging Approach To Evaluate The Delivery And Impact Of A Novel Imageable Theranostic Hydrogel Post Myocardial Infarction In A Chronic Porcine Model Journal Of Cardiovascular Computed Tomography 2020, 14: s27. DOI: 10.1016/j.jcct.2020.06.031.
- PROGNOSTIC IMPACT OF DIABETES IN PATIENTS WITH OR WITHOUT KNOWN CORONARY ARTERY DISEASE, RESULTS FROM THE REFINE SPECT REGISTRYHan D, Otaki Y, Tzolos E, Klein E, Gransar H, Sharir T, Einstein A, Fish M, Ruddy T, Kaufmann P, Sinusas A, Miller E, Bateman T, Dorbala S, Di Carli M, Liang J, Dey D, Berman D, Slomka P. PROGNOSTIC IMPACT OF DIABETES IN PATIENTS WITH OR WITHOUT KNOWN CORONARY ARTERY DISEASE, RESULTS FROM THE REFINE SPECT REGISTRY Journal Of The American College Of Cardiology 2020, 75: 1796. DOI: 10.1016/s0735-1097(20)32423-2.
- IMPAIRED CORONARY FLOW RESERVE ON 82RUBIDIUM POSITRON EMISSION TOMOGRAPHY IMAGING PREDICTS ADVERSE EVENTS IN PATIENTS WITH AUTOIMMUNE DISEASEFeher A, Boutagy N, Oikonomou E, Miller E, Sinusas A, Hinchcliff M. IMPAIRED CORONARY FLOW RESERVE ON 82RUBIDIUM POSITRON EMISSION TOMOGRAPHY IMAGING PREDICTS ADVERSE EVENTS IN PATIENTS WITH AUTOIMMUNE DISEASE Journal Of The American College Of Cardiology 2020, 75: 1726. DOI: 10.1016/s0735-1097(20)32353-6.
- 32 Cardiac Imaging in Heart FailureSt. John Sutton M, Morrison A, Sinusas A, Ferrari V. 32 Cardiac Imaging in Heart Failure 2020, 418-448.e5. DOI: 10.1016/b978-0-323-60987-6.00032-6.
- Application of Hybrid Matrix Metalloproteinase-Targeted and Dynamic 201Tl Single-Photon Emission Computed Tomography/Computed Tomography Imaging for Evaluation of Early Post-Myocardial Infarction RemodelingThorn SL, Barlow SC, Feher A, Stacy MR, Doviak H, Jacobs J, Zellars K, Renaud JM, Klein R, deKemp RA, Khakoo AY, Lee T, Spinale FG, Sinusas AJ. Application of Hybrid Matrix Metalloproteinase-Targeted and Dynamic 201Tl Single-Photon Emission Computed Tomography/Computed Tomography Imaging for Evaluation of Early Post-Myocardial Infarction Remodeling Circulation Cardiovascular Imaging 2019, 12: e009055. PMID: 31707811, PMCID: PMC7250243, DOI: 10.1161/circimaging.119.009055.
- Radionuclide ImagingStacy M, Chou T, Sinusas A. Radionuclide Imaging 2019, 195-215. DOI: 10.1007/978-3-030-24596-2_11.
- Noninvasive In Vivo Quantification of Adeno-Associated Virus Serotype 9–Mediated Expression of the Sodium/Iodide Symporter Under Hindlimb Ischemia and Neuraminidase Desialylation in Skeletal Muscle Using Single-Photon Emission Computed Tomography/Computed TomographyBoutagy NE, Ravera S, Papademetris X, Onofrey JA, Zhuang ZW, Wu J, Feher A, Stacy MR, French BA, Annex BH, Carrasco N, Sinusas AJ. Noninvasive In Vivo Quantification of Adeno-Associated Virus Serotype 9–Mediated Expression of the Sodium/Iodide Symporter Under Hindlimb Ischemia and Neuraminidase Desialylation in Skeletal Muscle Using Single-Photon Emission Computed Tomography/Computed Tomography Circulation Cardiovascular Imaging 2019, 12: e009063. PMID: 31296047, PMCID: PMC6629470, DOI: 10.1161/circimaging.119.009063.
- Molecular Imaging Targets in Heart Failure and Left Ventricular RemodelingBoutagy N, Feher A, Sikanderkhel S, Sinusas A. Molecular Imaging Targets in Heart Failure and Left Ventricular Remodeling 2019, 405-435. DOI: 10.1002/9781118754467.ch13.
- P289SPECT camera head configuration, acquisition time, and resolution recovery processing impact image defect size quantificationStendahl J, Weyman C, Liu Y, Liu C, Miller E, Sinusas A. P289SPECT camera head configuration, acquisition time, and resolution recovery processing impact image defect size quantification European Heart Journal - Cardiovascular Imaging 2019, 20 DOI: 10.1093/ehjci/jez148.018.
- Flow network tracking for spatiotemporal and periodic point matching: Applied to cardiac motion analysisParajuli N, Lu A, Ta K, Stendahl J, Boutagy N, Alkhalil I, Eberle M, Jeng GS, Zontak M, O'Donnell M, Sinusas AJ, Duncan JS. Flow network tracking for spatiotemporal and periodic point matching: Applied to cardiac motion analysis Medical Image Analysis 2019, 55: 116-135. PMID: 31055125, PMCID: PMC6939679, DOI: 10.1016/j.media.2019.04.007.
- Molecular Imaging of the HeartBoutagy NE, Feher A, Alkhalil I, Umoh N, Sinusas AJ. Molecular Imaging of the Heart 2019, 9: 477-533. PMID: 30873600, DOI: 10.1002/cphy.c180007.
- PREDICTING MAJOR ADVERSE CARDIAC EVENTS WITH COX NEURAL NETWORKS: RESULTS FROM THE REFINE SPECT REGISTRYSlomka P, Betancur J, Otaki Y, Commandeur F, Sharir T, Einstein A, Fish M, Ruddy T, Kaufmann P, Sinusas A, Miller E, Bateman T, Dorbala S, Di Carli M, Diniz M, Germano G, Dey D, Cooper L, Berman D. PREDICTING MAJOR ADVERSE CARDIAC EVENTS WITH COX NEURAL NETWORKS: RESULTS FROM THE REFINE SPECT REGISTRY Journal Of The American College Of Cardiology 2019, 73: 1432. DOI: 10.1016/s0735-1097(19)32038-8.
- TRANSIENT ISCHEMIC DILATATION IS INDEPENDENTLY ASSOCIATED WITH INCREASED CARDIOVASCULAR EVENTS IN PATIENTS WITHOUT ISCHEMIA: ANALYSIS OF THE REFINE REGISTRYMiller R, Hu L, Gransar H, Betancur J, Eisenberg E, Sharir T, Fish M, Ruddy T, Dorbala S, Di Carli M, Einstein A, Kaufmann P, Sinusas A, Miller E, Bateman T, Tamarappoo B, Dey D, Berman D, Slomka P. TRANSIENT ISCHEMIC DILATATION IS INDEPENDENTLY ASSOCIATED WITH INCREASED CARDIOVASCULAR EVENTS IN PATIENTS WITHOUT ISCHEMIA: ANALYSIS OF THE REFINE REGISTRY Journal Of The American College Of Cardiology 2019, 73: 1454. DOI: 10.1016/s0735-1097(19)32060-1.
- Stochastic Model-Based Left Ventricle Segmentation in 3D Echocardiography Using Fractional Brownian MotionAl-Kadi O, Lu A, Sinusas A, Duncan J. Stochastic Model-Based Left Ventricle Segmentation in 3D Echocardiography Using Fractional Brownian Motion 2019, 11395: 77-84. DOI: 10.1007/978-3-030-12029-0_9.
- New Method for Quantification of the Left Ventricular Function from Low-dose Equilibrium Radionuclide Angiocardiography: Comparisons with Conventional Methods in PatientsLiu Y, Tsatkin V, Fazzone-Chettiar R, Miller E, Sinusas A. New Method for Quantification of the Left Ventricular Function from Low-dose Equilibrium Radionuclide Angiocardiography: Comparisons with Conventional Methods in Patients 2018, 00: 1-3. DOI: 10.1109/nssmic.2018.8824749.
- Serial Assessment of Coronary Flow Reserve by Rubidium-82 Positron Emission Tomography Predicts Mortality in Heart Transplant RecipientsFeher A, Srivastava A, Quail MA, Boutagy NE, Khanna P, Wilson L, Miller EJ, Liu YH, Lee F, Sinusas AJ. Serial Assessment of Coronary Flow Reserve by Rubidium-82 Positron Emission Tomography Predicts Mortality in Heart Transplant Recipients JACC Cardiovascular Imaging 2018, 13: 109-120. PMID: 30343093, PMCID: PMC6461525, DOI: 10.1016/j.jcmg.2018.08.025.
- Development of a Direct Peritoneal Sodium Removal Technique with Salt Free SolutionMahoney D, Rao V, Asher J, Struyk G, Boutagy N, Feher A, Turner J, Sinusas A, Testani J. Development of a Direct Peritoneal Sodium Removal Technique with Salt Free Solution Journal Of Cardiac Failure 2018, 24: s34. DOI: 10.1016/j.cardfail.2018.07.099.
- Magnetic Resonance Imaging of Shear Stress and Wall Thickness in Tissue-Engineered Vascular GraftsStacy MR, Best CA, Maxfield MW, Qiu M, Naito Y, Kurobe H, Mahler N, Rocco KA, Sinusas A, Shinoka T, Sampath S, Breuer CK. Magnetic Resonance Imaging of Shear Stress and Wall Thickness in Tissue-Engineered Vascular Grafts Tissue Engineering Part C Methods 2018, 24: 465-473. PMID: 29978768, PMCID: PMC6088254, DOI: 10.1089/ten.tec.2018.0144.
- In Vivo Reactive Oxygen Species Detection With a Novel Positron Emission Tomography Tracer, 18F-DHMT, Allows for Early Detection of Anthracycline-Induced Cardiotoxicity in RodentsBoutagy NE, Wu J, Cai Z, Zhang W, Booth CJ, Kyriakides TC, Pfau D, Mulnix T, Liu Z, Miller EJ, Young LH, Carson RE, Huang Y, Liu C, Sinusas AJ. In Vivo Reactive Oxygen Species Detection With a Novel Positron Emission Tomography Tracer, 18F-DHMT, Allows for Early Detection of Anthracycline-Induced Cardiotoxicity in Rodents JACC Basic To Translational Science 2018, 3: 378-390. PMID: 30062224, PMCID: PMC6058999, DOI: 10.1016/j.jacbts.2018.02.003.
- Abstract 124: Radiotracer Imaging of Serial Changes in Angiosome Foot Perfusion in Critical Limb Ischemia Patients Undergoing Lower Extremity Revascularization: Association With 12-month Limb Salvage OutcomesChou T, Alvelo J, Papademetris X, Sumpio B, Sinusas A, Mena-Hurtado C, Stacy M. Abstract 124: Radiotracer Imaging of Serial Changes in Angiosome Foot Perfusion in Critical Limb Ischemia Patients Undergoing Lower Extremity Revascularization: Association With 12-month Limb Salvage Outcomes Arteriosclerosis Thrombosis And Vascular Biology 2018, 38 DOI: 10.1161/atvb.38.suppl_1.124.
- ANGIOTENSIN RECEPTOR NEPRILYSIN INHIBITOR THERAPY PROMOTES EARLY ANGIOGENESIS AND IMPROVES MYOCARDIAL PERFUSION INHIBITING POST-INFARCT REMODELINGThorn S, Tirziu D, Pfau D, Mikush N, Zhang J, Renaud J, Klein R, deKemp R, Wu X, Hu X, Young L, Sinusas A. ANGIOTENSIN RECEPTOR NEPRILYSIN INHIBITOR THERAPY PROMOTES EARLY ANGIOGENESIS AND IMPROVES MYOCARDIAL PERFUSION INHIBITING POST-INFARCT REMODELING Journal Of The American College Of Cardiology 2018, 71: a1466. DOI: 10.1016/s0735-1097(18)32007-2.
- Future directions for the development and application of hybrid cardiovascular imagingSinusas A. Future directions for the development and application of hybrid cardiovascular imaging 2017, 439-444. DOI: 10.1201/9781315374031-20.
- GPU-based List-mode Direct Parametric Reconstruction for Dynamic Cardiac SPECTShi L, Wu J, Lu Y, Gallezot J, Thorn S, Sinusas A, Carson R, Liu C. GPU-based List-mode Direct Parametric Reconstruction for Dynamic Cardiac SPECT 2017, 00: 1-3. DOI: 10.1109/nssmic.2017.8532889.
- Flow Network Based Cardiac Motion Tracking Leveraging Learned Feature MatchingParajuli N, Lu A, Stendahl J, Zontak M, Boutagy N, Alkhalil I, Eberle M, Lin B, O’Donnell M, Sinusas A, Duncan J. Flow Network Based Cardiac Motion Tracking Leveraging Learned Feature Matching 2017, 10434: 279-286. DOI: 10.1007/978-3-319-66185-8_32.
- Learning-Based Spatiotemporal Regularization and Integration of Tracking Methods for Regional 4D Cardiac Deformation AnalysisLu A, Zontak M, Parajuli N, Stendahl J, Boutagy N, Eberle M, Alkhalil I, O’Donnell M, Sinusas A, Duncan J. Learning-Based Spatiotemporal Regularization and Integration of Tracking Methods for Regional 4D Cardiac Deformation Analysis 2017, 10434: 323-331. DOI: 10.1007/978-3-319-66185-8_37.
- Fully automatic multi-atlas segmentation of CTA for partial volume correction in cardiac SPECT/CTLiu Q, Mohy-ud-Din H, Boutagy N, Jiang M, Ren S, Stendahl J, Sinusas A, Liu C. Fully automatic multi-atlas segmentation of CTA for partial volume correction in cardiac SPECT/CT Physics In Medicine And Biology 2017, 62: 3944-3957. PMID: 28266929, PMCID: PMC5568763, DOI: 10.1088/1361-6560/aa6520.
- Dictionary learning-based spatiotemporal regularization for 3D dense speckle trackingLu A, Zontak M, Parajuli N, Stendahl J, Boutagy N, Eberle M, O'Donnell M, Sinusas A, Duncan J. Dictionary learning-based spatiotemporal regularization for 3D dense speckle tracking Proceedings Of SPIE 2017, 10139: 1013904-1013904-8. DOI: 10.1117/12.2250695.
- RADIOTRACER IMAGING ALLOWS FOR ASSESSMENT OF SERIAL CHANGES IN ANGIOSOME FOOT PERFUSION FOLLOWING REVASCULARIZATION AND PREDICTS LIMB SALVAGE OUTCOMES IN PATIENTS WITH CRITICAL LIMB ISCHEMIABuckley J, Mena-Hurtado C, Jeon S, Papademetris X, Blume P, Sumpio B, Sinusas A, Stacy M. RADIOTRACER IMAGING ALLOWS FOR ASSESSMENT OF SERIAL CHANGES IN ANGIOSOME FOOT PERFUSION FOLLOWING REVASCULARIZATION AND PREDICTS LIMB SALVAGE OUTCOMES IN PATIENTS WITH CRITICAL LIMB ISCHEMIA Journal Of The American College Of Cardiology 2017, 69: 1393. DOI: 10.1016/s0735-1097(17)34782-4.
- COMPUTED TOMOGRAPHIC ANGIOGRAPHY CAN RELIABLY ASSESS EPICARDIAL CORONARY VASOREACTIVITY IN RESPONSE TO ADENOSINE AND DOBUTAMINEFeher A, John S, Boutagy N, Romito E, Liu C, Sinusas A. COMPUTED TOMOGRAPHIC ANGIOGRAPHY CAN RELIABLY ASSESS EPICARDIAL CORONARY VASOREACTIVITY IN RESPONSE TO ADENOSINE AND DOBUTAMINE Journal Of The American College Of Cardiology 2017, 69: 1503. DOI: 10.1016/s0735-1097(17)34892-1.
- RADIOTRACER IMAGING OF ANGIOSOME FOOT PERFUSION CORRELATES WITH ANKLE-BRACHIAL INDEX AND DIFFERENTIATES CRITICAL LIMB ISCHEMIA PATIENTS FROM HEALTHY SUBJECTSBuckley J, Papademetris X, Mena-Hurtado C, Blume P, Sumpio B, Sinusas A, Stacy M. RADIOTRACER IMAGING OF ANGIOSOME FOOT PERFUSION CORRELATES WITH ANKLE-BRACHIAL INDEX AND DIFFERENTIATES CRITICAL LIMB ISCHEMIA PATIENTS FROM HEALTHY SUBJECTS Journal Of The American College Of Cardiology 2017, 69: 1518. DOI: 10.1016/s0735-1097(17)34907-0.
- Exercise, metabolic syndrome, and cardiovascular fitness in breast cancer survivors.Knobf M, Sinusas A, Holland M, Jeon S. Exercise, metabolic syndrome, and cardiovascular fitness in breast cancer survivors. Journal Of Clinical Oncology 2017, 35: 165-165. DOI: 10.1200/jco.2017.35.5_suppl.165.
- Evaluation of structural remodeling of the atria with OCT in a chronic rat model of myocardial infarction (Conference Presentation)Eberle M, Thorn S, Young L, Pfau D, Madwed J, Small K, Kilmas M, Choma M, Sinusas A. Evaluation of structural remodeling of the atria with OCT in a chronic rat model of myocardial infarction (Conference Presentation) Proceedings Of SPIE 2017, 1004206-1004206-1. DOI: 10.1117/12.2252954.
- Integrated Dynamic Shape Tracking and RF Speckle Tracking for Cardiac Motion AnalysisParajuli N, Lu A, Stendahl J, Zontak M, Boutagy N, Eberle M, Alkhalil I, O’Donnell M, Sinusas A, Duncan J. Integrated Dynamic Shape Tracking and RF Speckle Tracking for Cardiac Motion Analysis 2016, 9900: 431-438. DOI: 10.1007/978-3-319-46720-7_50.
- Abstract 325: Non-Invasive Volumetric Assessment of Angiosome Perfusion in Diabetic Patients With Critical Limb Ischemia and Non-Healing Ulcers Using Radiotracer ImagingBuckley J, Mena C, Papademetris X, Blume P, Sumpio B, Sinusas A, Stacy M. Abstract 325: Non-Invasive Volumetric Assessment of Angiosome Perfusion in Diabetic Patients With Critical Limb Ischemia and Non-Healing Ulcers Using Radiotracer Imaging Arteriosclerosis Thrombosis And Vascular Biology 2016, 36 DOI: 10.1161/atvb.36.suppl_1.325.
- MICROVASCULAR ANGINA IN THE ABSENCE OF CORONARY ARTERY DISEASE IS COMMON IN UNDIFFERENTIATED CHEST PAIN PATIENTS IN THE EMERGENCY DEPARTMENTSafdar B, D’Onofrio G, Dziura J, Russell R, Naftilan M, Johnson C, Sinusas A. MICROVASCULAR ANGINA IN THE ABSENCE OF CORONARY ARTERY DISEASE IS COMMON IN UNDIFFERENTIATED CHEST PAIN PATIENTS IN THE EMERGENCY DEPARTMENT Journal Of The American College Of Cardiology 2016, 67: 1824. DOI: 10.1016/s0735-1097(16)31825-3.
- NORMAL LIMITS OF HEART-TO-MEDIASTINUM RATIO (HMR) OF I-123 MIBG UPTAKE QUANTIFIED FROM HIGH-SENSITIVITY (HS) AND HIGH-RESOLUTION (HR) SPECT/CTLiu Y, Zonouz T, Sandoval V, Lampert R, Sinusas A. NORMAL LIMITS OF HEART-TO-MEDIASTINUM RATIO (HMR) OF I-123 MIBG UPTAKE QUANTIFIED FROM HIGH-SENSITIVITY (HS) AND HIGH-RESOLUTION (HR) SPECT/CT Journal Of The American College Of Cardiology 2016, 67: 1822. DOI: 10.1016/s0735-1097(16)31823-x.
- High-Sensitivity and High-Resolution SPECT/CT Systems Provide Substantial Dose Reduction Without Compromising Quantitative Precision for Assessment of Myocardial Perfusion and FunctionPalyo RJ, Sinusas A, Liu YH. High-Sensitivity and High-Resolution SPECT/CT Systems Provide Substantial Dose Reduction Without Compromising Quantitative Precision for Assessment of Myocardial Perfusion and Function Journal Of Nuclear Medicine 2016, 57: 893-899. PMID: 26848173, DOI: 10.2967/jnumed.115.164632.
- Lower left atrial strain in the presence of regional atrial fibrosis: an MRI study of patients with atrial fibrillationPeters D, Duncan J, Grunseich K, Marieb M, Cornfeld D, Sinusas A, Chelikani S. Lower left atrial strain in the presence of regional atrial fibrosis: an MRI study of patients with atrial fibrillation Journal Of Cardiovascular Magnetic Resonance 2016, 18: p207. PMCID: PMC5032534, DOI: 10.1186/1532-429x-18-s1-p207.
- Simultaneous CT-MRI Reconstruction for Constrained Imaging Geometries Using Structural Coupling and Compressive SensingXi Y, Zhao J, Bennett J, Stacy M, Sinusas A, Wang G. Simultaneous CT-MRI Reconstruction for Constrained Imaging Geometries Using Structural Coupling and Compressive Sensing IEEE Transactions On Biomedical Engineering 2015, 63: 1301-1309. PMID: 26672028, PMCID: PMC4930897, DOI: 10.1109/tbme.2015.2487779.
- Assessment of Kinetic Modeling Quality of Fit by Cluster Analysis of Residuals: Application to Direct Reconstruction of Cardiac PET DataGermino M, Sinusas A, Liu C, Carson R. Assessment of Kinetic Modeling Quality of Fit by Cluster Analysis of Residuals: Application to Direct Reconstruction of Cardiac PET Data 2015, 1-4. DOI: 10.1109/nssmic.2015.7582243.
- Corrigendum to “Contour tracking in echocardiographic sequences via sparse representation and dictionary learning” [Med. Image Anal. 18 (2) (2014) 253–271]Huang X, Dione D, Compas C, Papademetris X, Lin B, Bregasi A, Sinusas A, Staib L, Duncan J. Corrigendum to “Contour tracking in echocardiographic sequences via sparse representation and dictionary learning” [Med. Image Anal. 18 (2) (2014) 253–271] Medical Image Analysis 2015, 22: 21. DOI: 10.1016/j.media.2015.01.006.
- Abstract 297: SPECT/CT Imaging of Regional Foot Perfusion Provides a Quantitative Index for Evaluation of Targeted Revascularization in the Diabetic FootStacy M, Papademetris X, Sumpio B, Sumpio B, Mena C, Sinusas A. Abstract 297: SPECT/CT Imaging of Regional Foot Perfusion Provides a Quantitative Index for Evaluation of Targeted Revascularization in the Diabetic Foot Arteriosclerosis Thrombosis And Vascular Biology 2015, 35 DOI: 10.1161/atvb.35.suppl_1.297.
- Moderated Poster Session 4Monday 4 May 2015, 15:30–16:30Room: Moderated Poster AreaWerner R, Maya Y, Yamane T, Rischpler C, Fukushima K, Chen X, Lapa C, Herrmann K, Higuchi T, Thorn S, Stacy M, Purcell B, Doviak H, Shuman J, Perez E, Burdick J, Spinale F, Sinusas A, Treibel T, Bandula S, Fontana M, White S, Gilbertson J, Punwani S, Gillmore J, Hawkins P, Taylor S, Moon J, Caobelli F, Wollenweber T, Kuehn C, Bavendiek U, Schuetze C, Geworski L, Bauersachs J, Haverich A, Bengel F, Barysheva N, Merkulova I, Shabanova M, Gaman S, Veselova T, Shariya M, Kelion A, Pakkal M, Chowdhury F, Nagaraj N, Birchall J, Dixon K, Banya W, Mccann G, Gershlick A, Rischpler C, Dirschinger R, Nicolosi S, Kossmann H, Meinicke A, Hanus F, Goetze K, Laugwitz K, Schwaiger M, Nekolla S, Rischpler C, Dirschinger R, Nicolosi S, Kossmann H, Meinicke A, Hanus F, Goetze K, Laugwitz K, Schwaiger M, Nekolla S. Moderated Poster Session 4Monday 4 May 2015, 15:30–16:30Room: Moderated Poster Area European Heart Journal - Cardiovascular Imaging 2015, 16: i35-i37. DOI: 10.1093/ehjci/jev050.
- Poster Session 1Sunday 3 May 2015, 08:30–18:00Room: Poster AreaTaniguchi Y, Takahashi Y, Toba T, Yamada S, Yokoi K, Kobayashi S, Okajima S, Shimane A, Kawai H, Yasaka Y, Smanio P, Oliveira M, Machado L, Cestari P, Medeiros E, Fukuzawa S, Okino S, Ikeda A, Maekawa J, Ichikawa S, Kuroiwa N, Yamanaka K, Igarashi A, Inagaki M, Patel K, Mahan M, Ananthasubramaniam K, Mouden M, Yokota S, Ottervanger J, Knollema S, Timmer J, Jager P, Padron K, Peix A, Cabrera L, Pena Bofill V, Valera D, Rodriguez Nande L, Carrillo Hernandez R, Mena Esnard E, Fernandez Columbie Y, Bertella E, Baggiano A, Mushtaq S, Segurini C, Loguercio M, Conte E, Beltrama V, Petulla' M, Andreini D, Pontone G, Guzic Salobir B, Dolenc Novak M, Jug B, Kacjan B, Novak Z, Vrtovec M, Mushtaq S, Pontone G, Bertella E, Conte E, Segurini C, Volpato V, Baggiano A, Formenti A, Pepi M, Andreini D, Ajanovic R, Husic-Selimovic A, Zujovic-Ajanovic A, Mlynarski R, Mlynarska A, Golba K, Sosnowski M, Ameta D, Goyal M, Kumar D, Chandra S, Sethi R, Puri A, Dwivedi S, Narain V, Saran R, Nekolla S, Rischpler C, Nicolosi S, Langwieser N, Dirschinger R, Laugwitz K, Schwaiger M, Goral J, Napoli J, Forcada P, Zucchiatti N, Damico A, Damico A, Olivieri D, Lavorato M, Dubesarsky E, Montana O, Salgado C, Jimenez-Heffernan A, Ramos-Font C, Lopez-Martin J, Sanchez De Mora E, Lopez-Aguilar R, Manovel A, Martinez A, Rivera F, Soriano E, Maroz-Vadalazhskaya N, Trisvetova E, Vrublevskaya O, Abazid R, Kattea M, Saqqah H, Sayed S, Smettei O, Winther S, Svensson M, Birn H, Jorgensen H, Botker H, Ivarsen P, Bottcher M, Maaniitty T, Stenstrom I, Saraste A, Pikkarainen E, Uusitalo V, Ukkonen H, Kajander S, Bax J, Knuuti J, Choi T, Park H, Lee C, Lee J, Seo Y, Cho Y, Hwang E, Cho D, Sanchez Enrique C, Ferrera C, Olmos C, Jimenez - Ballve A, Perez - Castejon M, Fernandez C, Vivas D, Vilacosta I, Nagamachi S, Onizuka H, Nishii R, Mizutani Y, Kitamura K, Lo Presti M, Polizzi V, Pino P, Luzi G, Bellavia D, Fiorilli R, Madeo A, Malouf J, Buffa V, Musumeci F, Rosales S, Puente A, Zafrir N, Shochat T, Mats A, Solodky A, Kornowski R, Lorber A, Boemio A, Pellegrino T, Paolillo S, Piscopo V, Carotenuto R, Russo B, Pellegrino S, De Matteis G, Perrone-Filardi P, Cuocolo A, Piscopo V, Pellegrino T, Boemio A, Carotenuto R, Russo B, Pellegrino S, De Matteis G, Petretta M, Cuocolo A, Amirov N, Ibatullin M, Sadykov A A, Saifullina G, Ruano R, Diego Dominguez M, Rodriguez Gabella T, Diego Nieto A, Diaz Gonzalez L, Garcia-Talavera J, Sanchez Fernandez P, Leen A, Al Younis I, Zandbergen-Harlaar S, Verberne H, Gimelli A, Veltman C, Wolterbeek R, Bax J, Scholte A, Mooney D, Rosenblatt J, Dunn T, Vasaiwala S, Okuda K, Nakajima K, Nystrom K, Edenbrandt L, Matsuo S, Wakabayashi H, Hashimoto M, Kinuya S, Iric-Cupic V, Milanov S, Davidovic G, Zdravkovic V, Ashikaga K, Yoneyama K, Akashi Y, Shugushev Z, Maximkin D, Chepurnoy A, Volkova O, Baranovich V, Faibushevich A, El Tahlawi M, Elmurr A, Alzubaidi S, Sakrana A, Gouda M, El Tahlawi R, Sellem A, Melki S, Elajmi W, Hammami H, Okano M, Kato T, Kimura M, Funasako M, Nakane E, Miyamoto S, Izumi T, Haruna T, Inoko M, Massardo T, Swett E, Fernandez R, Vera V, Zhindon J, Fernandez R, Swett E, Vera V, Zhindon J, Alay R, Massardo T, Ohshima S, Nishio M, Kojima A, Tamai S, Kobayashi T, Murohara T, Burrell S, Van Rosendael A, Van Den Hoogen I, De Graaf M, Roelofs J, Kroft L, Bax J, Scholte A, Rjabceva I, Krumina G, Kalvelis A, Chanakhchyan F, Vakhromeeva M, Kankiya E, Koppes J, Knol R, Wondergem M, Van Der Ploeg T, Van Der Zant F, Lazarenko S, Bruin V, Pan X, Declerck J, Van Der Zant F, Knol R, Juarez-Orozco L, Alexanderson E, Slart R, Tio R, Dierckx R, Zeebregts C, Boersma H, Hillege H, Martinez-Aguilar M, Jordan-Rios A, Christensen T, Ahtarovski K, Bang L, Holmvang L, Soeholm H, Ghotbi A, Andersson H, Ihlemann N, Kjaer A, Hasbak P, Gulya M, Lishmanov Y, Zavadovskii K, Lebedev D, Stahle M, Hellberg S, Liljenback H, Virta J, Metsala O, Yla-Herttuala S, Saukko P, Knuuti J, Saraste A, Roivainen A, Thackeray J, Wang Y, Bankstahl J, Wollert K, Bengel F, Saushkina Y, Evtushenko V, Minin S, Efimova I, Evtushenko A, Smishlyaev K, Lishmanov Y, Maslov L, Okuda K, Nakajima K, Kirihara Y, Sugino S, Matsuo S, Taki J, Hashimoto M, Kinuya S, Ahmadian A, Berman J, Govender P, Ruberg F, Miller E, Piriou N, Pallardy A, Valette F, Cahouch Z, Mathieu C, Warin-Fresse K, Gueffet J, Serfaty J, Trochu J, Kraeber-Bodere F, Van Dijk J, Mouden M, Ottervanger J, Van Dalen J, Jager P, Zafrir N, Ofrk H, Vaturi M, Shochat T, Hassid Y, Belzer D, Sagie A, Kornowski R, Kaminek M, Metelkova I, Budikova M, Koranda P, Henzlova L, Sovova E, Kincl V, Drozdova A, Jordan M, Shahid F, Teoh Y, Thamen R, Hara N, Onoguchi M, Hojyo O, Kawaguchi Y, Murai M, Udaka F, Matsuzawa Y, Bulugahapitiya D, Avison M, Martin J, Liu Y, Wu J, Liu C, Sinusas A, Daou D, Sabbah R, Bouladhour H, Coaguila C, Aguade-Bruix S, Pizzi M, Romero-Farina G, Candell-Riera J, Castell-Conesa J, Patchett N, Sverdlov A, Miller E, Daou D, Sabbah R, Bouladhour H, Coaguila C, Smettei O, Abazid R, Boulaamayl El Fatemi S, Sallam L, Snipelisky D, Park J, Ray J, Shapiro B, Kostkiewicz M, Szot W, Holcman K, Lesniak-Sobelga A, Podolec P, Clerc O, Possner M, Liga R, Vontobel J, Mikulicic F, Graeni C, Benz D, Herzog B, Gaemperli O, Kaufmann P. Poster Session 1Sunday 3 May 2015, 08:30–18:00Room: Poster Area European Heart Journal - Cardiovascular Imaging 2015, 16: i11-i28. DOI: 10.1093/ehjci/jev051.
- Left atrial function after myocardial infarction in swinePeters D, Diaz E, Bregazi A, Thorn S, Stacy M, Hawley C, Sinusas A. Left atrial function after myocardial infarction in swine Journal Of Cardiovascular Magnetic Resonance 2015, 17: p142. PMCID: PMC4328575, DOI: 10.1186/1532-429x-17-s1-p142.
- Left atrial late gadolinium enhancement and mitral regurgitation in subjects with atrial fibrillationGrunseich K, Peters D, Sinusas A, Mojibian H, Marieb M, Cornfeld D, Simprini L. Left atrial late gadolinium enhancement and mitral regurgitation in subjects with atrial fibrillation Journal Of Cardiovascular Magnetic Resonance 2015, 17: p358. PMCID: PMC4328568, DOI: 10.1186/1532-429x-17-s1-p358.
- Towards high-resolution fat-suppressed T1-mapping of atrial fibrosis in the left atrium: a fit-free three-point methodPeters D, Thorn S, Bregazi A, Hawley C, Stacy M, Sinusas A. Towards high-resolution fat-suppressed T1-mapping of atrial fibrosis in the left atrium: a fit-free three-point method Journal Of Cardiovascular Magnetic Resonance 2015, 17: w17. PMCID: PMC4328894, DOI: 10.1186/1532-429x-17-s1-w17.
- Abstract 19973: Dynamic Thallium-201 SPECT/CT Provides Quantitative Index of Myocardial Flow and Viability: Validation in Porcine Post-Myocardial Infarction ModelThorn S, Stacy M, Bregasi A, Paeng J, Tavakoli V, Winters J, Hawley C, Tang Y, Bennett J, Wells R, Liu C, Klein R, Sinusas A. Abstract 19973: Dynamic Thallium-201 SPECT/CT Provides Quantitative Index of Myocardial Flow and Viability: Validation in Porcine Post-Myocardial Infarction Model Circulation 2014, 130 DOI: 10.1161/circ.130.suppl_2.19973.
- Abstract 20211: Contrast Improvement of Biodegradable Stents for X-ray Computed Tomography VisualizationWinters J, Bennett J, Guelcher M, Mathur A, Martin J, Fahmy T, Sinusas A. Abstract 20211: Contrast Improvement of Biodegradable Stents for X-ray Computed Tomography Visualization Circulation 2014, 130 DOI: 10.1161/circ.130.suppl_2.20211.
- Direct EM Reconstruction of Kinetic Parameters from List-Mode Cardiac PETGermino M, Sinusas A, Liu C, Carson R. Direct EM Reconstruction of Kinetic Parameters from List-Mode Cardiac PET 2014, 1-4. DOI: 10.1109/nssmic.2014.7430812.
- Chemokine-coupled β 2 integrin–induced macrophage Rac2–Myosin IIA interaction regulates VEGF-A mRNA stability and arteriogenesisMorrison A, Yarovinsky T, Young B, Moraes F, Ross T, Ceneri N, Zhang J, Zhuang Z, Sinusas A, Pardi R, Schwartz M, Simons M, Bender J. Chemokine-coupled β 2 integrin–induced macrophage Rac2–Myosin IIA interaction regulates VEGF-A mRNA stability and arteriogenesis Journal Of Cell Biology 2014, 206: 2066oia157. DOI: 10.1083/jcb.2066oia157.
- Biodistribution and Radiation Dosimetry of LMI1195: First-in-Human Study of a Novel 18F-Labeled Tracer for Imaging Myocardial InnervationSinusas AJ, Lazewatsky J, Brunetti J, Heller G, Srivastava A, Liu YH, Sparks R, Puretskiy A, Lin SF, Crane P, Carson RE, Lee LV. Biodistribution and Radiation Dosimetry of LMI1195: First-in-Human Study of a Novel 18F-Labeled Tracer for Imaging Myocardial Innervation Journal Of Nuclear Medicine 2014, 55: 1445-1451. PMID: 24994931, DOI: 10.2967/jnumed.114.140137.
- POLYMER IODINATION FOR IMPROVED IN VITRO TRACKING OF BIODEGRADABLE STENT DEGRADATION: SERIAL MICROCT IMAGING FOR BIOREACTOR TESTINGWinters J, Lee J, Guelcher M, Mathur A, Martin J, Fahmy T, Sinusas A. POLYMER IODINATION FOR IMPROVED IN VITRO TRACKING OF BIODEGRADABLE STENT DEGRADATION: SERIAL MICROCT IMAGING FOR BIOREACTOR TESTING Journal Of The American College Of Cardiology 2014, 63: a1049. DOI: 10.1016/s0735-1097(14)61049-4.
- CLINICAL FEASIBILITY STUDY TO DETECT ANGIOGENESIS FOLLOWING BONE MARROW STEM CELL TRANSPLANTATION IN CHRONIC ISCHAEMIC HEART FAILUREMozid B, Holstensson M, Ben-Haim S, Martin J, Sinusas A, Hutton B, Mathur A. CLINICAL FEASIBILITY STUDY TO DETECT ANGIOGENESIS FOLLOWING BONE MARROW STEM CELL TRANSPLANTATION IN CHRONIC ISCHAEMIC HEART FAILURE Journal Of The American College Of Cardiology 2014, 63: a902. DOI: 10.1016/s0735-1097(14)60902-5.
- Evaluation of peak skeletal muscle perfusion in the lower extremities of athletes using arterial spin labelingStacy M, Caracciolo C, Qiu M, Sinusas A. Evaluation of peak skeletal muscle perfusion in the lower extremities of athletes using arterial spin labeling Journal Of Cardiovascular Magnetic Resonance 2014, 16: p164. PMCID: PMC4044373, DOI: 10.1186/1532-429x-16-s1-p164.
- Phase rotation in correlation coefficient filtering and multi-pass methods for 3-D speckle tracking in 4-D echocardiographyWong E, O'Donnell M, Compas C, Lin B, Sinusas A, Duncan J. Phase rotation in correlation coefficient filtering and multi-pass methods for 3-D speckle tracking in 4-D echocardiography 2014, 1-4. DOI: 10.1109/ultsym.2014.0001.
- Multimodality Imaging Approach for Serial Assessment of Regional Changes in Lower Extremity Arteriogenesis and Tissue Perfusion in a Porcine Model of Peripheral Arterial DiseaseStacy MR, Yu da Y, Maxfield MW, Jaba IM, Jozwik BP, Zhuang ZW, Lin BA, Hawley CL, Caracciolo CM, Pal P, Tirziu D, Sampath S, Sinusas AJ. Multimodality Imaging Approach for Serial Assessment of Regional Changes in Lower Extremity Arteriogenesis and Tissue Perfusion in a Porcine Model of Peripheral Arterial Disease Circulation Cardiovascular Imaging 2013, 7: 92-99. PMID: 24170237, PMCID: PMC3929970, DOI: 10.1161/circimaging.113.000884.
- Simultaneous Partial Volume Correction and Noise Regularization for Cardiac SPECT/CTChan C, Liu H, Grobshtein Y, Stacy M, Sinusas A, Liu C. Simultaneous Partial Volume Correction and Noise Regularization for Cardiac SPECT/CT 2013, 1-6. DOI: 10.1109/nssmic.2013.6829070.
- Potential Impact of Hybrid CZT SPECT/CT Imaging on Estimation Accuracy of Left Ventricular Volumes and Ejection Fraction: A Phantom StudyLiu Y, Sandoval V, Sinusas A. Potential Impact of Hybrid CZT SPECT/CT Imaging on Estimation Accuracy of Left Ventricular Volumes and Ejection Fraction: A Phantom Study 2013, 1-5. DOI: 10.1109/nssmic.2013.6829398.
- 3D Molecular Breast Imaging Using a High-Resolution Dedicated Cardiac SPECT CameraLiu H, Chan C, Grobshtein Y, Ma T, Liu Y, Wang S, Kench P, Sinusas A, Liu C. 3D Molecular Breast Imaging Using a High-Resolution Dedicated Cardiac SPECT Camera 2013, 1-4. DOI: 10.1109/nssmic.2013.6829097.
- Myocardial blood flow from dynamic PET using Independent Component AnalysisKarpikov A, Tagare H, Mulnix T, Gallezot J, Sinusas A, Liu C, Carson R. Myocardial blood flow from dynamic PET using Independent Component Analysis 2011 IEEE Nuclear Science Symposium Conference Record 2013, 2222-2226. DOI: 10.1109/nssmic.2012.6551506.
- 4-D echocardiography assessment of local myocardial strain using 3-D speckle tracking combined with shape trackingWong E, O'Donnell M, Thiele K, Comnas C, Huang X, Sampath S, Lin B, Pal P, Papademetris X, Dione D, Staib L, Sinusas A, Duncan J. 4-D echocardiography assessment of local myocardial strain using 3-D speckle tracking combined with shape tracking 2013, 100-103. DOI: 10.1109/ultsym.2013.0026.
- Multi-Band Confidence Processing for Two-Pass Speckle TrackingWong E, Odonnell M, Compas C, Lin B, Sinusas A, Duncan J. Multi-Band Confidence Processing for Two-Pass Speckle Tracking 2012, 200-203. DOI: 10.1109/ultsym.2012.0050.
- A COMBINED SHAPE TRACKING AND SPECKLE TRACKING APPROACH FOR 4D DEFORMATION ANALYSIS IN ECHOCARDIOGRAPHYCompas C, Wong E, Huang X, Sampath S, Lin B, Papademetris X, Thiele K, Dione D, Sinusas A, O'Donnell M, Duncan J. A COMBINED SHAPE TRACKING AND SPECKLE TRACKING APPROACH FOR 4D DEFORMATION ANALYSIS IN ECHOCARDIOGRAPHY 2012, 1: 458-461. DOI: 10.1109/isbi.2012.6235583.
- IS A 3D SPECKLE TRACKING ALGORITHM SYNONYMOUS WITH BETTER ESTIMATION OF LEFT VENTRICULAR FUNCTION?Bellavia D, Nesser J, Weinert L, Johannes N, Mor-Avi V, Lang R, Sinusas A, Sugeng L. IS A 3D SPECKLE TRACKING ALGORITHM SYNONYMOUS WITH BETTER ESTIMATION OF LEFT VENTRICULAR FUNCTION? Journal Of The American College Of Cardiology 2012, 59: e1287. DOI: 10.1016/s0735-1097(12)61288-1.
- 3rd Multimodality Cardiovascular Molecular Imaging Symposium—Poster AbstractsSinusas A. 3rd Multimodality Cardiovascular Molecular Imaging Symposium—Poster Abstracts Journal Of Nuclear Medicine 2012, 53: 664-671. DOI: 10.2967/jnumed.112.105254.
- Early diastolic function observed in canine model of reperfused transmural myocardial infarction using high temporal resolution MR imagingZhang Z, Dione D, Lin B, Duncan J, Sinusas A, Sampath S. Early diastolic function observed in canine model of reperfused transmural myocardial infarction using high temporal resolution MR imaging Journal Of Cardiovascular Magnetic Resonance 2012, 14: w65. PMCID: PMC3305634, DOI: 10.1186/1532-429x-14-s1-w65.
- Flow vortex quantification in the left atriumPal P, Zhang Z, Lin B, Dione D, Sinusas A, Sampath S. Flow vortex quantification in the left atrium Journal Of Cardiovascular Magnetic Resonance 2012, 14: w23. PMCID: PMC3305578, DOI: 10.1186/1532-429x-14-s1-w23.
- Automated Segmentation of Real-Time 3D Echocardiography Using an Incompressibility ConstraintZhu Y, Papademetris X, Sinusas A, Duncan J. Automated Segmentation of Real-Time 3D Echocardiography Using an Incompressibility Constraint 2012 DOI: 10.5772/28992.
- Segmentation of left ventricles from echocardiographic sequences via sparse appearance representationHuang X, Lin B, Compas C, Sinusas A, Staib L, Duncan J. Segmentation of left ventricles from echocardiographic sequences via sparse appearance representation 2012, 305-312. DOI: 10.1109/mmbia.2012.6164769.
- Multimodality Fusion ImagingKraitchman J, Wu D, Criscione J, Sinusas A, Fahmy T. Multimodality Fusion Imaging 2011, 20111830: 317-334. DOI: 10.1201/b11182-19.
- Multimodality Fusion Imaging: Toward Imaging of Structure and FunctionCriscione J, Sinusas A, Fahmy T. Multimodality Fusion Imaging: Toward Imaging of Structure and Function 2011, 340-357. DOI: 10.1201/b11182-22.
- Respiratory Gating for A Stationary Dedicated Cardiac SPECT SystemLiu C, Chan C, Harris M, Le M, Biondi J, Volokh L, Sinusas A. Respiratory Gating for A Stationary Dedicated Cardiac SPECT System 2011, 2898-2901. DOI: 10.1109/nssmic.2011.6152514.
- Comparing Shape Tracking, Speckle Tracking, and a Combined Method for Deformation Analysis in EchocardiographyCompas C, Lin B, Sampath S, Huang L, Wei Q, Sinusas A, Duncan J. Comparing Shape Tracking, Speckle Tracking, and a Combined Method for Deformation Analysis in Echocardiography 2011, 120-125. DOI: 10.1109/hisb.2011.16.
- Targeted Imaging of the Spatial and Temporal Variation of Matrix Metalloproteinase Activity in a Porcine Model of Postinfarct RemodelingSahul ZH, Mukherjee R, Song J, McAteer J, Stroud RE, Dione DP, Staib L, Papademetris X, Dobrucki LW, Duncan JS, Spinale FG, Sinusas AJ. Targeted Imaging of the Spatial and Temporal Variation of Matrix Metalloproteinase Activity in a Porcine Model of Postinfarct Remodeling Circulation Cardiovascular Imaging 2011, 4: 381-391. PMID: 21505092, PMCID: PMC3140564, DOI: 10.1161/circimaging.110.961854.
- 82RB POSITRON EMISSION TOMOGRAPHY (PET) MYOCARDIAL BLOOD FLOW (MBF) CORRELATES WITH CORONARY ARTERY INTIMAL THICKNESS MEASURED BY INTRAVASCULAR ULTRASOUND (IVUS) FOLLOWING HEART TRANSPLANTATIONMohani A, Khanna P, Liu Y, Sinusas A, Lee F. 82RB POSITRON EMISSION TOMOGRAPHY (PET) MYOCARDIAL BLOOD FLOW (MBF) CORRELATES WITH CORONARY ARTERY INTIMAL THICKNESS MEASURED BY INTRAVASCULAR ULTRASOUND (IVUS) FOLLOWING HEART TRANSPLANTATION Journal Of The American College Of Cardiology 2011, 57: e848. DOI: 10.1016/s0735-1097(11)60848-6.
- SEGMENTATION OF 3D RF ECHOCARDIOGRAPHY USING A JOINT SPATIO-TEMPORAL PREDICTOR AND SIGNAL INTENSITY MODELPearlman P, Tagare H, Lin B, Sinusas A, Duncan J. SEGMENTATION OF 3D RF ECHOCARDIOGRAPHY USING A JOINT SPATIO-TEMPORAL PREDICTOR AND SIGNAL INTENSITY MODEL 2011, 649-652. DOI: 10.1109/isbi.2011.5872490.
- COMBINING SHAPE AND SPECKLE TRACKING FOR DEFORMATION ANALYSIS IN ECHOCARDIOGRAPHY USING RADIAL BASIS FUNCTIONSCompos C, Lin B, Sampath S, Sinusas A, Duncan J. COMBINING SHAPE AND SPECKLE TRACKING FOR DEFORMATION ANALYSIS IN ECHOCARDIOGRAPHY USING RADIAL BASIS FUNCTIONS 2011, 1: 1322-1325. DOI: 10.1109/isbi.2011.5872644.
- Multi-frame Radial Basis Functions to Combine Shape and Speckle Tracking for Cardiac Deformation Analysis in EchocardiographyCompas C, Lin B, Sampath S, Jia C, Wei Q, Sinusas A, Duncan J. Multi-frame Radial Basis Functions to Combine Shape and Speckle Tracking for Cardiac Deformation Analysis in Echocardiography 2011, 6666: 113-120. DOI: 10.1007/978-3-642-21028-0_14.
- 3D elasticity imaging using principal stretches on an open-chest dog heartJia C, Yan P, Sinusas A, Dione D, Lin B, Wei Q, Thiele K, Kolias J, Rubin J, Huang L, Duncan J, O'Donnell M. 3D elasticity imaging using principal stretches on an open-chest dog heart 2010, 583-586. DOI: 10.1109/ultsym.2010.5935864.
- Regional matrix metalloproteinase activation correlates with microstructure diffusion tensor indices post myocardial infarctionMekkaoui C, Jackowski M, Martuzzi R, Dione D, Spinale F, Sinusas A. Regional matrix metalloproteinase activation correlates with microstructure diffusion tensor indices post myocardial infarction Journal Of Cardiovascular Magnetic Resonance 2010, 12: p241. DOI: 10.1186/1532-429x-12-s1-p241.
- Chapter 3 Role of Intact Biological Models for Evaluation of RadiotracersSinusas A. Chapter 3 Role of Intact Biological Models for Evaluation of Radiotracers 2010, 27-49. DOI: 10.1016/b978-0-323-05796-7.00003-5.
- Chapter 43 Molecular Imaging Approaches for Evaluation of Myocardial Pathophysiology Angiogenesis, Ventricular Remodeling, Inflammation, and Cell DeathMorrison A, Sinusas A. Chapter 43 Molecular Imaging Approaches for Evaluation of Myocardial Pathophysiology Angiogenesis, Ventricular Remodeling, Inflammation, and Cell Death 2010, 691-712. DOI: 10.1016/b978-0-323-05796-7.00075-8.
- 3D Elasticity Imaging on an Open-chest Dog heartJia C, Kolias T, Rubin J, Yan P, Sinusas A, Dione D, Duncan J, Wei Q, Thiele K, Huang L, Huang S, O'Donnell M. 3D Elasticity Imaging on an Open-chest Dog heart 2009, 155-158. DOI: 10.1109/ultsym.2009.5441850.
- Characterization of myocardial remodeling with diffusion tensor magnetic resonance imaging in chronic porcine model using the toroid-based representationMekkaoui C, Jackowski M, Dione D, Spinale F, Sinusas A. Characterization of myocardial remodeling with diffusion tensor magnetic resonance imaging in chronic porcine model using the toroid-based representation Journal Of Cardiovascular Magnetic Resonance 2009, 11: p79. PMCID: PMC7860676, DOI: 10.1186/1532-429x-11-s1-p79.
- Abstracts of the Otorhinolaryngological Research Society Meeting Autumn Meeting26th September 2008, UCL Ear Institute, Gray's Inn Road, LondonPrasad S, Cody V, Hanlon D, Roberts S, Filler R, Edelson R, Dobrucki W, Sinusas A, Girardi M, Birchall M. Abstracts of the Otorhinolaryngological Research Society Meeting Autumn Meeting26th September 2008, UCL Ear Institute, Gray's Inn Road, London Clinical Otolaryngology 2008, 33: 644-644. DOI: 10.1111/j.1749-4486.2008.01843_11.x.
- Abstract 5826: MicroSPECT-CT Imaging Demonstrates Impairment of Matrix Metalloproteinases Activation in Ischemic Peripheral Angiogenesis in Type-1 Diabetes Associated with GlycationDobrucki L, Dione D, Kalinowski L, Sinusas A. Abstract 5826: MicroSPECT-CT Imaging Demonstrates Impairment of Matrix Metalloproteinases Activation in Ischemic Peripheral Angiogenesis in Type-1 Diabetes Associated with Glycation Circulation 2008, 118 DOI: 10.1161/circ.118.suppl_18.s_1012-a.
- 1081 Toroid-based characterization of myocardial structure using diffusion tensor magnetic resonance imagingMekkaoui C, Jackowski M, Sinusas A. 1081 Toroid-based characterization of myocardial structure using diffusion tensor magnetic resonance imaging Journal Of Cardiovascular Magnetic Resonance 2008, 10: a206. DOI: 10.1186/1532-429x-10-s1-a206.
- Integrated Segmentation and Motion Analysis of Cardiac MR Images Using a Subject-Specific Dynamical ModelZhu Y, Papademetris X, Sinusas A, Duncan J. Integrated Segmentation and Motion Analysis of Cardiac MR Images Using a Subject-Specific Dynamical Model 2008, 1-8. DOI: 10.1109/cvprw.2008.4563007.
- INTEGRATED SEGMENTATION AND DEFORMATION ANALYSIS OF 4-D CARDIAC MR IMAGESZhu Y, Yan P, Papademetris X, Sinusas A, Duncan J. INTEGRATED SEGMENTATION AND DEFORMATION ANALYSIS OF 4-D CARDIAC MR IMAGES 2008, 1437-1440. DOI: 10.1109/isbi.2008.4541277.
- Hotspot quantification of myocardial focal tracer uptake from molecular targeted SPECT/CT images: experimental validationLiu Y, Sahul Z, Weyman C, Ryder W, Dione D, Dobrucki L, Mekkaoui C, Brennan M, Hu X, Hawley C, Sinusas A. Hotspot quantification of myocardial focal tracer uptake from molecular targeted SPECT/CT images: experimental validation Proceedings Of SPIE 2008, 6915: 69150n-69150n-8. DOI: 10.1117/12.768985.
- Generic iterative reconstruction of multi-pinhole SPECTRyder W, Brennan M, Sinusas A, Liu Y. Generic iterative reconstruction of multi-pinhole SPECT Proceedings Of SPIE 2008, 6913: 69132m-69132m-10. DOI: 10.1117/12.769519.
- Abstract 3191: Experimental Validation Using Radiolabeled Microspheres of Absolute Quantitation of Regional Myocardial Blood Flow (MBF) Using Dynamic Rb-82 Positron Emission Tomography (PET)El Fakhri G, Mekkaoui C, Sitek A, Dione D, Carson R, Brennan M, Di Carli M, Sinusas A. Abstract 3191: Experimental Validation Using Radiolabeled Microspheres of Absolute Quantitation of Regional Myocardial Blood Flow (MBF) Using Dynamic Rb-82 Positron Emission Tomography (PET) Circulation 2007, 116 DOI: 10.1161/circ.116.suppl_16.ii_717-b.
- 4D Elasticity Imaging of PVA LV Phantom Integrated with Pulsatile Circulation System Using 2D Phased ArrayJia C, Kim K, Kolias T, Rubin J, Weitzel W, Yan P, Dione D, Sinusas A, Duncan J, O'Donnell M. 4D Elasticity Imaging of PVA LV Phantom Integrated with Pulsatile Circulation System Using 2D Phased Array 2014 IEEE International Ultrasonics Symposium 2007, 876-879. DOI: 10.1109/ultsym.2007.224.
- Local Shape Registration Using Boundary-Constrained Match of SkeletonsZhu Y, Papademetris X, Sinusas A, Duncan J. Local Shape Registration Using Boundary-Constrained Match of Skeletons 2007, 1-8. DOI: 10.1109/cvpr.2007.383427.
- 6.4New method of scatter correction for quantification of molecular targeted cardiac images: canine validationLIU Y, WEYMAN C, DIONE D, SAHUL Z, DOBRUCKI W, BRENNAN M, MEKKAOUI C, SINUSAS A. 6.4New method of scatter correction for quantification of molecular targeted cardiac images: canine validation Journal Of Nuclear Cardiology 2007, 14: s39-s39. DOI: 10.1016/j.nuclcard.2006.12.157.
- 8.16Local IGF-1 gene delivery post myocardial infarction affects temporal and regional Alpha-V integrin activation as assessed with radiolabelled RGD peptideWAWRZYNIECDOBRUCKI L, TSUTSUMI Y, KALINOWSKI L, DEAN J, SEN S, MENDIZABAL M, AIKAWA R, SINUSAS A. 8.16Local IGF-1 gene delivery post myocardial infarction affects temporal and regional Alpha-V integrin activation as assessed with radiolabelled RGD peptide Journal Of Nuclear Cardiology 2007, 14: s61-s61. DOI: 10.1016/j.nuclcard.2006.12.243.
- 8.17Temporal changes in myocardial uptake of alpha-v integrin targeted tracer correlate with serum markers of collagen turnover and left ventricular function in setting of post-infarct angiogenesisKALINOWSKI L, SAHUL Z, DOBRUCKI L, BRENNAN M, EVANS P, HARAMIS H, MADRI J, SINUSAS A. 8.17Temporal changes in myocardial uptake of alpha-v integrin targeted tracer correlate with serum markers of collagen turnover and left ventricular function in setting of post-infarct angiogenesis Journal Of Nuclear Cardiology 2007, 14: s62-s62. DOI: 10.1016/j.nuclcard.2006.12.244.
- 8.18Left ventricular dysfunction post myocardial infarction does not alter the biodistribution, or clearance kinetics of a targeted radiotracer for imaging angiogenesisWEYMAN C, DIONE D, SAHUL Z, DOBRUCKI W, KALINOWSKI L, MEKKAOUI C, HARAMIS H, SINUSAS A. 8.18Left ventricular dysfunction post myocardial infarction does not alter the biodistribution, or clearance kinetics of a targeted radiotracer for imaging angiogenesis Journal Of Nuclear Cardiology 2007, 14: s62-s62. DOI: 10.1016/j.nuclcard.2006.12.245.
- Imaging of AngiogenesisDobrucki L, Sinusas A. Imaging of Angiogenesis 2007, 394-411. DOI: 10.1007/978-0-387-38295-1_26.
- Detection of Complex Vascular Structures using Polar Neighborhood Intensity ProfileQian X, Brennan M, Dione D, Dobrucki W, Jackowski M, Breuer C, Sinusas A, Papademetris X. Detection of Complex Vascular Structures using Polar Neighborhood Intensity Profile 2015 IEEE International Conference On Computer Vision (ICCV) 2007, 1-8. DOI: 10.1109/iccv.2007.4409172.
- CARDIAC MR IMAGE SEGMENTATION WITH INCOMPRESSIBILITY CONSTRAINTZhu Y, Papademetris X, Duncan J, Sinusas A. CARDIAC MR IMAGE SEGMENTATION WITH INCOMPRESSIBILITY CONSTRAINT 2007, 185-188. DOI: 10.1109/isbi.2007.356819.
- LV SEGMENTATION FROM 3D ECHOCARDIOGRAPHY USING FUZZY FEATURES AND A MULTILEVEL FFD MODELYan P, Sinusas A, Duncan J. LV SEGMENTATION FROM 3D ECHOCARDIOGRAPHY USING FUZZY FEATURES AND A MULTILEVEL FFD MODEL 2007, 848-851. DOI: 10.1109/isbi.2007.356985.
- LV STRAIN ESTIMATION FROM 4D ECHOCARDIOGRAPHYDuncan J, Yan P, Zhu Y, Sinusas A, Jia C, Donnell M. LV STRAIN ESTIMATION FROM 4D ECHOCARDIOGRAPHY 2007, 696-699. DOI: 10.1109/isbi.2007.356947.
- A New Method for Hot-Spot Quantification of Hybrid SPECT/CT Cardiac Images: Methodology and Preliminary Phantom ValidationLiu Y, Fernando G, Sinusas A. A New Method for Hot-Spot Quantification of Hybrid SPECT/CT Cardiac Images: Methodology and Preliminary Phantom Validation IEEE Transactions On Nuclear Science 2006, 53: 2814-2821. DOI: 10.1109/tns.2006.879823.
- Sampled-Data ηα Filtering for Robust Kinematics Estimation: Applications to Biomechanics-Based Cardiac Image AnalysisTong S, Sinusas A, Shi P. Sampled-Data ηα Filtering for Robust Kinematics Estimation: Applications to Biomechanics-Based Cardiac Image Analysis 2014 IEEE International Conference On Image Processing (ICIP) 2006, 2525-2528. DOI: 10.1109/icip.2006.312955.
- 16.24Myocardial hotspot quantification of targeted radiotracer using hybrid micro-SPECT/CTLI S, DOBRUCKI W, SINUSAS A, LIU Y. 16.24Myocardial hotspot quantification of targeted radiotracer using hybrid micro-SPECT/CT Journal Of Nuclear Cardiology 2006, 13: s19-s19. DOI: 10.1016/j.nuclcard.2006.06.063.
- Development of a mouse model for evaluation of tissue engineered human vascular graftsLopez-Soler R, Brennan M, Wang Y, Sinusas A, Dardik A, Pober J, Breuer C. Development of a mouse model for evaluation of tissue engineered human vascular grafts Journal Of Surgical Research 2006, 130: 268. DOI: 10.1016/j.jss.2005.11.307.
- Boundary Element Method-Based Scattered Feature Interpolation Algorithm in the Analysis of LV DeformationYan P, Sinusas A, Duncan J. Boundary Element Method-Based Scattered Feature Interpolation Algorithm in the Analysis of LV Deformation 2006, 1-8. DOI: 10.1109/cvprw.2006.47.
- Continuous-Discrete Filtering for Cardiac Kinematics Estimation under Spatio-Temporal Biomechanical ConstrainsTong S, Sinusas A, Shi P. Continuous-Discrete Filtering for Cardiac Kinematics Estimation under Spatio-Temporal Biomechanical Constrains 2006, 1: 167-170. DOI: 10.1109/icpr.2006.413.
- A hybrid positron detection and optical coherence tomography system: design, calibration, and experimental validation with rabbit atherosclerotic modelsZhu Q, Piao D, Sadeghi M, Zhang J, Chen Y, Sinusas A. A hybrid positron detection and optical coherence tomography system: design, calibration, and experimental validation with rabbit atherosclerotic models Proceedings Of SPIE 2005, 5690: 356-364. DOI: 10.1117/12.592603.
- PET and molecular imaging oral abstract sessionLevkau B, Hermann S, Baba H, Stegger L, Flögel U, Schrader J, Schäfers K, Schober O, Schäfers M, Koutelou M, Kollaros N, Theodorakos A, Manginas A, Peristeri I, Tsapaki V, Kouzoumi A, Cokkinos D, Hosokawa R, Ohba M, Kambara N, Tadamura E, Kimura T, Nohara R, Kita T, Panjrath G, Patel V, Narula N, Narula J, Jain D, Dobrucki L, Lindsey M, Song J, Escobar G, Su H, Bourke B, Mendizabal M, Spinale F, Sinusas A, Herrero P, Kisrieva-Ware Z, Dence C, Coggan A, Eisenbeis P, Scott S, Welch M, Gropler R. PET and molecular imaging oral abstract session Journal Of Nuclear Cardiology 2005, 12: s14-s15. DOI: 10.1016/j.nuclcard.2004.12.093.
- Matrix metalloproteinase-9 gene deletion enhances angiogenesis following myocardial infarctionDOBRUCKI L, LINDSEY M, SONG J, ESCOBAR G, SU H, BOURKE B, MENDIZABAL M, SPINALE F, SINUSAS A. Matrix metalloproteinase-9 gene deletion enhances angiogenesis following myocardial infarction Journal Of Nuclear Cardiology 2005, 12: s15-s15. DOI: 10.1016/j.nuclcard.2004.12.161.
- A stochastic approach for quantification of hotspot focal uptake from cardiac SPECT/CT images: A canine validationLIU Y, LI S, BOURKE B, WEYMAN C, SINUSAS A. A stochastic approach for quantification of hotspot focal uptake from cardiac SPECT/CT images: A canine validation Journal Of Nuclear Cardiology 2005, 12: s73-s73. DOI: 10.1016/j.nuclcard.2004.12.169.
- Book reviewsBateman T, Sinusas A, Dobrucki W. Book reviews Journal Of Nuclear Cardiology 2004, 11: 364-366. DOI: 10.1016/j.nuclcard.2004.02.002.
- Abstracts of Original Contributions Cardiovascular Molecular Imaging Symposium May 3–4, 2004 Bethesda, MarylandLahoutte T, Vanhove C, Caveliers V, Defrise M, Everaert H, Bossuyt A, Franken P, Schäfers K, Kriens M, Barnard C, Schober O, Schäfers M, Kopka K, Wagner S, Law M, Riemann B, Pike V, Herrero P, Dence C, Kisrieva-Ware Z, Eisenbeis P, Welch M, Gropler R, Bucerius J, Joe A, Schmaliohann J, Gündisch D, Reinhardt M, Biersack H, Wüllner U, Ranney D, Peshock R, McDonald G, Slomka P, deKemp R, Beanlands R, Nishina H, Abidov A, Berman D, Germano G, Riou L, Goode A, Hatada K, Ruiz M, Lima R, Harris T, Beller G, Glover D, Kim H, Miceli M, Delbeke D, Bhargava P, Jackson L, Walker R, Anaissie E, Alavi A, Hanrahan S, Janabi M, Taylor S, Rychak J, Klibanov A, Leppanen A, Cummings R, Ley K, Rychak J, Klibanov A, Hossack J, Dence C, Herrero P, Gropler R, Welch M, Veress A, Feng B, Yang Y, Weiss J, Huesman R, Gullberg G, Sharp T, Herrero P, Englebach J, Fettig N, Gropler R, Welch M, Dobrucki L, Hua J, Bourke B, Sadeghi M, Cavaliere P, Mendizabal M, VanRoyen N, Buschmann I, Sinusas A, Sadeghi M, Zhang J, Fassaei H, Krassilnikova S, Esmailzadeh L, Gharaei A, Kooshkabadi A, Edwards D, Harris T, Yalamanchili P, Sinusas A, Zaret B, Bender J, Epstein F, Gilson W, Sureau F, Yang Z, French B, Lewis S, Lu X, Tom E, Felix M, Gretton J, Varghese R, Wagner W, Villanueva F. Abstracts of Original Contributions Cardiovascular Molecular Imaging Symposium May 3–4, 2004 Bethesda, Maryland Journal Of Nuclear Cardiology 2004, 11: 367-373. DOI: 10.1007/bf02972758.
- 1170-150 Evaluation of the roll-off of radiotracer uptake under adenosine, dobutamine and nitroglycerin stress: Demonstration of flow dependencePurushothaman K, Jahanshad N, Gross N, Cavaliere P, Hu X, Bourke B, Sinusas A. 1170-150 Evaluation of the roll-off of radiotracer uptake under adenosine, dobutamine and nitroglycerin stress: Demonstration of flow dependence Journal Of The American College Of Cardiology 2004, 43: a369-a370. DOI: 10.1016/s0735-1097(04)91564-1.
- 1116-23 Noninvasive detection of angiogenesis with a technetium-99m labeled peptide targeted at αvβ3 integrin following hindlimb ischemiaHua J, Bourke B, Song J, Chow C, Sadeghi M, Cavaliere P, Hu X, Jahanshad N, Dobrucki L, VanRoyen N, Mendizabal M, Buschmann I, Sinusas A. 1116-23 Noninvasive detection of angiogenesis with a technetium-99m labeled peptide targeted at αvβ3 integrin following hindlimb ischemia Journal Of The American College Of Cardiology 2004, 43: a25. DOI: 10.1016/s0735-1097(04)90102-7.
- Simultaneous Recovery of Left Ventricular Shape and Motion Using Meshfree Particle FrameworkWong A, Liu H, Sinusas A, Shi P. Simultaneous Recovery of Left Ventricular Shape and Motion Using Meshfree Particle Framework 2004, 2: 1263-1266. DOI: 10.1109/isbi.2004.1398775.
- Robust Filtering Strategies for Soft Tissue Young 'S Modulus CharacterizationShi P, Liu H, Sinusas A. Robust Filtering Strategies for Soft Tissue Young 'S Modulus Characterization 2004, 2: 768-771. DOI: 10.1109/isbi.2004.1398651.
- Pointwise Motion Tracking in Echocardiographic ImagesYu W, Yan P, Sinusas A, Thiele K, Duncan J. Pointwise Motion Tracking in Echocardiographic Images 2004, 1: i-676-i-683. DOI: 10.1109/cvpr.2004.1315097.
- Meshfree Cardiac Motion Analysis Using Composite Material Model and Total Lagrangian FormulationWong C, Liu H, Wong L, Sinusas A, Shi P. Meshfree Cardiac Motion Analysis Using Composite Material Model and Total Lagrangian Formulation 2004, 2: 464-467. DOI: 10.1109/isbi.2004.1398575.
- Motion Analysis of 3D Ultrasound Texture PatternsYu W, Lin N, Yan P, Purushothaman K, Sinusas A, Thiele K, Duncan J. Motion Analysis of 3D Ultrasound Texture Patterns 2003, 2674: 253-261. DOI: 10.1007/3-540-44883-7_26.
- Myocardial perfusion imaging with a novel selective A2a adenosine receptor agonist (CVT-3146): Important differences in radiotracer behaviorJadbabaie F, Meoli D, Bourke B, Purushothaman K, Brown L, Belardinelli L, Sinusas A. Myocardial perfusion imaging with a novel selective A2a adenosine receptor agonist (CVT-3146): Important differences in radiotracer behavior Journal Of The American College Of Cardiology 2003, 41: 443-444. DOI: 10.1016/s0735-1097(03)81346-3.
- Effects of a new selective A2a adenosine receptor agonist on Thallium-201 and Tcm99-MIBI biodistribution and clearance: Implications for optimizing vasodilator stress perfusion imagingJadbabaie F, Meoli D, Bourke B, Purushothaman K, Sullivan S, Belardinelli L, Sinusas A. Effects of a new selective A2a adenosine receptor agonist on Thallium-201 and Tcm99-MIBI biodistribution and clearance: Implications for optimizing vasodilator stress perfusion imaging Journal Of The American College Of Cardiology 2003, 41: 461. DOI: 10.1016/s0735-1097(03)82547-0.
- Analysis of Left Ventricular Motion Using a General Robust Point Matching AlgorithmLin N, Papademetris X, Sinusas A, Duncan J. Analysis of Left Ventricular Motion Using a General Robust Point Matching Algorithm 2003, 2878: 556-563. DOI: 10.1007/978-3-540-39899-8_69.
- Joint Analysis of Heart Geometry and Kinematics with Spatiotemporal Active Region ModelWong A, Shi P, Liu H, Sinusas A. Joint Analysis of Heart Geometry and Kinematics with Spatiotemporal Active Region Model 2003, 1: 762-765. DOI: 10.1109/iembs.2003.1279876.
- Gated SPECT Quantification for Myocardial Thickness, Left Ventricular Volumes and Ejection Fraction: Methodology and Phantom ValidationLiu Y, Khaimov D, Sinusas A, Wackers F. Gated SPECT Quantification for Myocardial Thickness, Left Ventricular Volumes and Ejection Fraction: Methodology and Phantom Validation 2003, 4: 2955-2959. DOI: 10.1109/nssmic.2003.1352503.
- Does contrast echocardiography provide new insight regarding regulation of microcirculatory flow and stress perfusion imaging?Sinusas A, Kailasnath P. Does contrast echocardiography provide new insight regarding regulation of microcirculatory flow and stress perfusion imaging? Journal Of Nuclear Cardiology 2001, 8: 707-710. PMID: 11725268, DOI: 10.1067/mnc.2001.120368.
- Estimation of coronary flow reserve: Can SPECT compete with other modalities?Gullberg G, Di Bella E, Sinusas A. Estimation of coronary flow reserve: Can SPECT compete with other modalities? Journal Of Nuclear Cardiology 2001, 8: 620-625. PMID: 11593228, DOI: 10.1067/mnc.2001.118121.
- Quantification of 3-D regional myocardial deformation: shape-based analysis of magnetic resonance imagesSinusas A, Papademetris X, Constable R, Dione D, Slade M, Shi P, Duncan J. Quantification of 3-D regional myocardial deformation: shape-based analysis of magnetic resonance images AJP Heart And Circulatory Physiology 2001, 281: h698-h714. PMID: 11454574, DOI: 10.1152/ajpheart.2001.281.2.h698.
- Comparison of Tl-201 with Tc-99m-labeled myocardial perfusion agents: Technical, physiologic, and clinical issuesKailasnath P, Sinusas A. Comparison of Tl-201 with Tc-99m-labeled myocardial perfusion agents: Technical, physiologic, and clinical issues Journal Of Nuclear Cardiology 2001, 8: 482-498. PMID: 11481571, DOI: 10.1067/mnc.2001.115078.
- The Active Elastic ModelPapademetris X, Constable R, Onat E, Duncan J, Sinusas A, Dione D. The Active Elastic Model 2001, 2082: 36-49. DOI: 10.1007/3-540-45729-1_4.
- Activation of glucose transport in the ischemic heart: Translocation of GLUT4 and GLUT1 by 5′-AMP-activated protein kinaseYoung L, Russell R, Coven D, Shulman G, Sinusas A. Activation of glucose transport in the ischemic heart: Translocation of GLUT4 and GLUT1 by 5′-AMP-activated protein kinase Journal Of Molecular And Cellular Cardiology 2001, 33: a145. DOI: 10.1016/s0022-2828(01)90556-5.
- Technetium-99m-labeled Myocardial Perfusion Agents: Are They Better than Thallium-201?Kailasnath P, Sinusas A. Technetium-99m-labeled Myocardial Perfusion Agents: Are They Better than Thallium-201? Cardiology In Review 2001, 9: 160-172. PMID: 11304401, DOI: 10.1097/00045415-200105000-00009.
- Estimation of 3D left ventricular deformation from echocardiographyPapademetris X, Sinusas A, Dione D, Duncan J. Estimation of 3D left ventricular deformation from echocardiography Medical Image Analysis 2001, 5: 17-28. PMID: 11231174, DOI: 10.1016/s1361-8415(00)00022-0.
- Computational Platforms for Integrated Cardiac Image AnalysisPapademetris X, Sinusas A, Duncan J. Computational Platforms for Integrated Cardiac Image Analysis 2001, 23: 289-313. DOI: 10.1007/978-94-015-1265-7_11.
- 16.53 Differences in regional myocardial permeability of TL-201 and TC99m-tetrofosmin under dobutamine stressKAILASNATH P, PREMKUMAR P, DIONE D, SINUSAS A. 16.53 Differences in regional myocardial permeability of TL-201 and TC99m-tetrofosmin under dobutamine stress Journal Of Nuclear Cardiology 2001, 8: s110-s110. DOI: 10.1016/s1071-3581(01)80840-0.
- 17.3 Transmyocardial excimer laser revascularization results in improvement of resting myocardial flowBEDAIR H, DIONE D, ARRIGHI J, PAPADEMETRIS X, CONDOS S, CONSTABLE R, DUNCAN J, SOUFER R, SINUSAS A. 17.3 Transmyocardial excimer laser revascularization results in improvement of resting myocardial flow Journal Of Nuclear Cardiology 2001, 8: s112-s112. DOI: 10.1016/s1071-3581(01)80849-7.
- Assessment of left ventricular ejection fraction with quantitative gated SPECT: Accuracy and correlation with first-pass radionuclide angiographyVallejo E, Dione D, Sinusas A, Wackers F. Assessment of left ventricular ejection fraction with quantitative gated SPECT: Accuracy and correlation with first-pass radionuclide angiography Journal Of Nuclear Cardiology 2000, 7: 461-470. PMID: 11083195, DOI: 10.1067/mnc.2000.107820.
- Technetium 99m-N-NOET: Although not equivalent to thallium-201, it still offers new opportunitiesSinusas A. Technetium 99m-N-NOET: Although not equivalent to thallium-201, it still offers new opportunities Journal Of Nuclear Cardiology 2000, 7: 185. PMID: 10796010, DOI: 10.1016/s1071-3581(00)90043-6.
- Acute ischemic dysfunction alters coronary flow reserve in remote nonischemic regions: Potential mechanical etiology identified in an acute canine modelDaher E, Dione D, Heller E, Holahan J, DeMan P, Shen M, Hu J, Sinusas A. Acute ischemic dysfunction alters coronary flow reserve in remote nonischemic regions: Potential mechanical etiology identified in an acute canine model Journal Of Nuclear Cardiology 2000, 7: 112-122. PMID: 10796000, DOI: 10.1016/s1071-3581(00)90031-x.
- Severe regional ischemia alters coronary flow reserve in the remote perfusion areaWu J, Yun J, Dione D, Heller E, Deckelbaum L, Sinusas A. Severe regional ischemia alters coronary flow reserve in the remote perfusion area Journal Of Nuclear Cardiology 2000, 7: 43-52. PMID: 10698234, DOI: 10.1067/mnc.2000.99189.
- Estimating 3D Strain from 4D Cine-MRI and Echocardiography: In-Vivo ValidationPapademetris X, Sinusas A, Dione D, Constable R, Duncan J. Estimating 3D Strain from 4D Cine-MRI and Echocardiography: In-Vivo Validation 2000, 1935: 678-686. DOI: 10.1007/978-3-540-40899-4_70.
- Quantification of regional myocardial wall thickening on electrocardiogram-gated SPECT imagingShen M, Liu Y, Sinusas A, Fetterman R, Bruni W, Drozhinin O, Zaret B, Wackers F. Quantification of regional myocardial wall thickening on electrocardiogram-gated SPECT imaging Journal Of Nuclear Cardiology 1999, 6: 583-595. PMID: 10608585, DOI: 10.1016/s1071-3581(99)90095-8.
- Volumetric Deformation Analysis Using Mechanics-Based Data Fusion: Applications in Cardiac Motion RecoveryShi P, Sinusas A, Constable R, Duncan J. Volumetric Deformation Analysis Using Mechanics-Based Data Fusion: Applications in Cardiac Motion Recovery International Journal Of Computer Vision 1999, 35: 87-107. DOI: 10.1023/a:1008163112590.
- The potential for myocardial imaging with hypoxia markersSinusas A. The potential for myocardial imaging with hypoxia markers Seminars In Nuclear Medicine 1999, 29: 330-338. PMID: 10534235, DOI: 10.1016/s0001-2998(99)80020-8.
- Recovery of Soft Tissue Object Deformation from 3D Image Sequences Using Biomechanical ModelsPapademetris X, Shi P, Dione D, Sinusas A, Constable R, Duncan J. Recovery of Soft Tissue Object Deformation from 3D Image Sequences Using Biomechanical Models 1999, 1613: 352-357. DOI: 10.1007/3-540-48714-x_28.
- Regulation of myocardial glucose uptake and transport during ischemia and energetic stressYoung L, Russell R, Yin R, Caplan M, Ren J, Bergeron R, Shulman G, Sinusas A. Regulation of myocardial glucose uptake and transport during ischemia and energetic stress The American Journal Of Cardiology 1999, 83: 25-30. PMID: 10750583, DOI: 10.1016/s0002-9149(99)00253-2.
- Quantification of SPECT myocardial perfusion images: Methodology and validation of the Yale-CQ methodLiu Y, Sinusas A, DeMan P, Zaret B, Wackers F. Quantification of SPECT myocardial perfusion images: Methodology and validation of the Yale-CQ method Journal Of Nuclear Cardiology 1999, 6: 190-203. PMID: 10327104, DOI: 10.1016/s1071-3581(99)90080-6.
- 3D Cardiac Deformation from Ultrasound ImagesPapademetris X, Sinusas A, Dione D, Duncan J. 3D Cardiac Deformation from Ultrasound Images 1999, 1679: 420-429. DOI: 10.1007/10704282_46.
- Physiological monitoring using digital sonomicrometry via telemetryBeaty J, Tagare H, Dione D, Sinusas A, Wilder D. Physiological monitoring using digital sonomicrometry via telemetry 1999, 125-126. DOI: 10.1109/nebc.1999.755793.
- Additive Effects of Hyperinsulinemia and Ischemia on Myocardial GLUT1 and GLUT4 Translocation In VivoRussell R, Yin R, Caplan M, Hu X, Ren J, Shulman G, Sinusas A, Young L. Additive Effects of Hyperinsulinemia and Ischemia on Myocardial GLUT1 and GLUT4 Translocation In Vivo Circulation 1998, 98: 2180-2186. PMID: 9815873, DOI: 10.1161/01.cir.98.20.2180.
- Exercise testing with myocardial perfusion imaging in patients with normal baseline electrocardiograms: Cost savings with a stepwise diagnostic strategyMattera J, Arain S, Sinusas A, Finta L, Wackers F. Exercise testing with myocardial perfusion imaging in patients with normal baseline electrocardiograms: Cost savings with a stepwise diagnostic strategy Journal Of Nuclear Cardiology 1998, 5: 498-506. PMID: 9796897, DOI: 10.1016/s1071-3581(98)90181-7.
- A novel geometry for SPECT imaging associated with the EM-type blind deconvolution methodLiu Y, Rangarajan A, Gagnon D, Therrien M, Sinusas A, Wackers F, Zubal I. A novel geometry for SPECT imaging associated with the EM-type blind deconvolution method IEEE Transactions On Nuclear Science 1998, 45: 2095-2101. DOI: 10.1109/23.708310.
- Experimental evaluation of radiotracers: Role of intact biological modelsSinusas A. Experimental evaluation of radiotracers: Role of intact biological models Journal Of Nuclear Cardiology 1998, 5: 167-183. PMID: 9588669, DOI: 10.1016/s1071-3581(98)90200-8.
- Physical and geometrical modeling for image-based recovery of left ventricular deformationDuncan J, Shi P, Constable T, Sinusas A. Physical and geometrical modeling for image-based recovery of left ventricular deformation Progress In Biophysics And Molecular Biology 1998, 69: 333-351. PMID: 9785945, DOI: 10.1016/s0079-6107(98)00014-5.
- Visually interactive semi-automated 3D segmentation of cine cardiac magnetic resonance imagesPapademetris X, Rambo J, Dione D, Sinusas A, Duncan J. Visually interactive semi-automated 3D segmentation of cine cardiac magnetic resonance images Journal Of The American College Of Cardiology 1998, 31: 7. DOI: 10.1016/s0735-1097(98)80687-6.
- Three-dimensional digital sonomicrometry: comparison with biplane radiographyMeoli D, Mazhari R, Dione D, Omens J, McCulloch A, Sinusas A. Three-dimensional digital sonomicrometry: comparison with biplane radiography 1998, 64-67. DOI: 10.1109/nebc.1998.664878.
- Long QTc and Torsades de Pointes in Human Immunodeficiency Virus DiseaseKOCHERIL A, BOKHARI S, BATSFORD W, SINUSAS A. Long QTc and Torsades de Pointes in Human Immunodeficiency Virus Disease Pacing And Clinical Electrophysiology 1997, 20: 2810-2816. PMID: 9392812, DOI: 10.1111/j.1540-8159.1997.tb05439.x.
- Low-flow ischemia leads to translocation of canine heart GLUT-4 and GLUT-1 glucose transporters to the sarcolemma in vivo.Young L, Renfu Y, Russell R, Hu X, Caplan M, Ren J, Shulman G, Sinusas A. Low-flow ischemia leads to translocation of canine heart GLUT-4 and GLUT-1 glucose transporters to the sarcolemma in vivo. Circulation 1997, 95: 415-22. PMID: 9008459, DOI: 10.1161/01.cir.95.2.415.
- New methods for SPECT imaging and pre-reconstruction restorationLiu Y, Rangarajan A, Gagnon D, Therrien M, Sinusas A, Wackers F, Zubal G. New methods for SPECT imaging and pre-reconstruction restoration 1997, 1230: 531-536. DOI: 10.1007/3-540-63046-5_55.
- The Yale-CQ method for cardiac SPECT quantification: phantom validation and patient applicationLiu Y, DeMan P, Sinusas A, Natale D, Wackers F. The Yale-CQ method for cardiac SPECT quantification: phantom validation and patient application 1997, 3: 1091-1093 vol.3. DOI: 10.1109/iembs.1996.652723.
- Three-dimensional regional left ventricular deformation from digital sonomicrometryDione D, Shi P, Smith W, DeMan P, Soares J, Duncan J, Sinusas A. Three-dimensional regional left ventricular deformation from digital sonomicrometry Annual International Conference Of The IEEE Engineering In Medicine And Biology Society (EMBC) 1997, 2: 848-851 vol.2. DOI: 10.1109/iembs.1997.757790.
- A novel geometry for SPECT imaging associated with the EM-type blind deconvolution methodLiu Y, Rangarajan A, Gagnon D, Therrien M, Sinusas A, Wackers F, Zubal I. A novel geometry for SPECT imaging associated with the EM-type blind deconvolution method 2011 IEEE Nuclear Science Symposium Conference Record 1997, 2: 1014-1017 vol.2. DOI: 10.1109/nssmic.1997.670482.
- Quantitative comparison of single-isotope and dual-isotope stress-rest single-photon emission computed tomographic imaging for reversibility of defectsSiebelink H, Natale D, Sinusas A, Wackers F. Quantitative comparison of single-isotope and dual-isotope stress-rest single-photon emission computed tomographic imaging for reversibility of defects Journal Of Nuclear Cardiology 1996, 3: 483-493. PMID: 8989673, DOI: 10.1016/s1071-3581(96)90058-6.
- Quantification of technetium 99m-labeled sestamibi single-photon emission computed tomography based on mean counts improves accuracy for assessment of relative regional myocardial blood flow: Experimental validation in a canine modelLiu Y, Sinusas A, Shi C, Shen M, Dione D, Heller E, Wackers F. Quantification of technetium 99m-labeled sestamibi single-photon emission computed tomography based on mean counts improves accuracy for assessment of relative regional myocardial blood flow: Experimental validation in a canine model Journal Of Nuclear Cardiology 1996, 3: 312-320. PMID: 8799250, DOI: 10.1016/s1071-3581(96)90091-4.
- Limitations of ECG-gated SPECT for assessment of regional thickening: Experimental comparison with ECG-gated MRIGradel C, Staib L, Heller E, Constable R, Dione D, Liu Y, Wackers F, Sinusas A. Limitations of ECG-gated SPECT for assessment of regional thickening: Experimental comparison with ECG-gated MRI Journal Of The American College Of Cardiology 1996, 27: 241. DOI: 10.1016/s0735-1097(96)81838-9.
- Detection of myocardial ischemia with dynamic SPECT I-123-lodophenylpentadecanoic acid (IPPA) imagingDaher E, Shi C, Heller E, Liu Y, DeMan P, Dione D, Wackers F, Sinusas A. Detection of myocardial ischemia with dynamic SPECT I-123-lodophenylpentadecanoic acid (IPPA) imaging Journal Of The American College Of Cardiology 1996, 27: 407-408. DOI: 10.1016/s0735-1097(96)82567-8.
- Assessment of reperfusion after acute myocardial infarction: Is there a role for acute technetium 99m-teboroxime imaging?Sinusas A. Assessment of reperfusion after acute myocardial infarction: Is there a role for acute technetium 99m-teboroxime imaging? Journal Of Nuclear Cardiology 1996, 3: 82-85. PMID: 8799231, DOI: 10.1016/s1071-3581(96)90027-6.
- Dense nonrigid motion tracking from a sequence of velocity fieldsMeyer F, Constable R, Sinusas A, Duncan J. Dense nonrigid motion tracking from a sequence of velocity fields 2015 IEEE Conference On Computer Vision And Pattern Recognition (CVPR) 1996, 839-844. DOI: 10.1109/cvpr.1996.517169.
- Kinetic analysis of technetium-99m-labeled nitroimidazole (BMS-181321) as a tracer of myocardial hypoxia.Ng C, Sinusas A, Zaret B, Soufer R. Kinetic analysis of technetium-99m-labeled nitroimidazole (BMS-181321) as a tracer of myocardial hypoxia. Circulation 1995, 92: 1261-8. PMID: 7648674, DOI: 10.1161/01.cir.92.5.1261.
- Phantom evaluation of non-uniform attenuation correction using simultaneous transmission emission SPECTDEMAN P, EROR E, LIU Y, MATTERA J, WACKERS F, SINUSAS A. Phantom evaluation of non-uniform attenuation correction using simultaneous transmission emission SPECT Journal Of Nuclear Cardiology 1995, 2: s48-s48. DOI: 10.1016/s1071-3581(05)80276-4.
- Selection of 180° or 360° reconstruction affects the determination of changes in I123-phenylpentadecanoic acid (IPPA) defect magnitudeBRUNI W, DAHER E, LIU Y, SAARI M, WACKERS F, SINUSAS A. Selection of 180° or 360° reconstruction affects the determination of changes in I123-phenylpentadecanoic acid (IPPA) defect magnitude Journal Of Nuclear Cardiology 1995, 2: s6-s6. DOI: 10.1016/s1071-3581(05)80110-2.
- Quantitative comparison of single-isotope and adual-isotope stress-rest SPECT imaging for defect reversibilitySIEBELINCK H, NATALE D, SINUSAS A, WACKERS F. Quantitative comparison of single-isotope and adual-isotope stress-rest SPECT imaging for defect reversibility Journal Of Nuclear Cardiology 1995, 2: s19-s19. DOI: 10.1016/s1071-3581(05)80162-x.
- Dobutamine stress has limited value for enhancing flow heterogeneity in the presence of a moderate stenosis: Implications for Tc99M-sestamibi imagingYUN J, WU J, HELLER E, DECKELBAUM L, DIONE D, LIU Y, WACKERS F, SINUSAS A. Dobutamine stress has limited value for enhancing flow heterogeneity in the presence of a moderate stenosis: Implications for Tc99M-sestamibi imaging Journal Of Nuclear Cardiology 1995, 2: s88-s88. DOI: 10.1016/s1071-3581(05)80435-0.
- 913-117 Tc99m-Furifosmin Organ Clearance and Heart/Organ Ratio After Exercise and at Rest: Implication for Timing of ImagingDaher E, Sinusas A, Wackers F, Natale D, Bruni W, Investigators T. 913-117 Tc99m-Furifosmin Organ Clearance and Heart/Organ Ratio After Exercise and at Rest: Implication for Timing of Imaging Journal Of The American College Of Cardiology 1995, 25: 69a. DOI: 10.1016/0735-1097(95)91739-k.
- 962-67 Dobutamine Stress has a Limited Value for Enhancing Flow Heterogeneity in the Presence of a Moderate Stenosis When Used in Conjunction with Tc99m-Sestamibi ImagingYun J, Wu J, Heller E, Deckelbaum L, Dione D, Liu Y, Wackers F, Sinusas A. 962-67 Dobutamine Stress has a Limited Value for Enhancing Flow Heterogeneity in the Presence of a Moderate Stenosis When Used in Conjunction with Tc99m-Sestamibi Imaging Journal Of The American College Of Cardiology 1995, 25: 217a. DOI: 10.1016/0735-1097(95)92360-h.
- 913-116 Quantitative Comparison of Planar and SPECT Normal Databases of Thallium-201, Sestamibi, Tetrofosmin and FurifosminNaruse H, Daher E, Sinusas A, Jain D, Natale D, Wackers F. 913-116 Quantitative Comparison of Planar and SPECT Normal Databases of Thallium-201, Sestamibi, Tetrofosmin and Furifosmin Journal Of The American College Of Cardiology 1995, 25: 69a. DOI: 10.1016/0735-1097(95)91738-j.
- A Unified Framework to Assess Myocardial Function from 4D ImagesShi P, Robinson G, Chakraborty A, Staib L, Constable R, Sinusas A, Duncan J. A Unified Framework to Assess Myocardial Function from 4D Images 1995, 905: 327-337. DOI: 10.1007/978-3-540-49197-2_42.
- Letters to the editorSinusas A, Meizlish J, Brown K, Saha M, Farrand T. Letters to the editor Journal Of Nuclear Cardiology 1995, 2: 98-98. PMID: 9420772, DOI: 10.1016/s1071-3581(05)80020-0.
- Cardiac SPECT restoration using MR-based support constraintsStaib L, Sinusas A. Cardiac SPECT restoration using MR-based support constraints 1995, 2: 480-483 vol.2. DOI: 10.1109/icip.1995.537520.
- Validation of a new SPECT quantification method using computer simulationLiu Y, Sinusas A, Wackers F. Validation of a new SPECT quantification method using computer simulation 1995, 3: 1506-1509 vol.3. DOI: 10.1109/nssmic.1995.500312.
- A model-based integrated approach to track myocardial deformation using displacement and velocity constraintsShi P, Robinson G, Constable R, Sinusas A, Duncan J. A model-based integrated approach to track myocardial deformation using displacement and velocity constraints 1995, 687-692. DOI: 10.1109/iccv.1995.466872.
- One-year prognosis of patients with normal planar or single-photon emission computed tomographic technetium 99m-labeled sestamibi exercise imagingRaiker K, Sinusas A, Wackers F, Zaret B. One-year prognosis of patients with normal planar or single-photon emission computed tomographic technetium 99m-labeled sestamibi exercise imaging Journal Of Nuclear Cardiology 1994, 1: 449-456. PMID: 9420729, DOI: 10.1007/bf02961599.
- Development and evaluation of tracking algorithms for cardiac wall motion analysis using phase velocity MR imagingConstable R, Rath K, Sinusas A, Gore J. Development and evaluation of tracking algorithms for cardiac wall motion analysis using phase velocity MR imaging Magnetic Resonance In Medicine 1994, 32: 33-42. PMID: 8084235, DOI: 10.1002/mrm.1910320106.
- Toward reliable, noninvasive measurement of myocardial function from 4D imagesDuncan J, Shi P, Amimi A, Constable R, Staib L, Dione D, Shi Q, Heller E, Singer M, Chakraborty A, Robinson G, Gore J, Sinusas A. Toward reliable, noninvasive measurement of myocardial function from 4D images Proceedings Of SPIE 1994, 2168: 149-161. DOI: 10.1117/12.174390.
- Effects of altered left ventricular geometry on quantitative technetium 99m sestamibi defect size in humans: Perfusion imaging during coronary angioplastyHaronian H, Sinusas A, Remetz M, Brennan J, Cabin H, Zaret B, Wackers F. Effects of altered left ventricular geometry on quantitative technetium 99m sestamibi defect size in humans: Perfusion imaging during coronary angioplasty Journal Of Nuclear Cardiology 1994, 1: 150-158. PMID: 9420682, DOI: 10.1007/bf02984087.
- Intracoronary Ethanol Ablation in Swine:HAINES D, VEROW A, SINUSAS A, WHAYNE J, DiMARCO J. Intracoronary Ethanol Ablation in Swine: Journal Of Cardiovascular Electrophysiology 1994, 5: 41-49. PMID: 8186876, DOI: 10.1111/j.1540-8167.1994.tb01113.x.
- Does myocardial free fatty acid metabolism predict subsequent mechanical dysfunction associated with cardiomyopathy?Sinusas A. Does myocardial free fatty acid metabolism predict subsequent mechanical dysfunction associated with cardiomyopathy? Journal Of Nuclear Cardiology 1994, 1: 218-220. PMID: 9420690, DOI: 10.1007/bf02984095.
- Shape-based 4D left ventricular myocardial function analysisShi P, Amini A, Robinson G, Sinusas A, Constable C, Duncan J. Shape-based 4D left ventricular myocardial function analysis 1994, 88-97. DOI: 10.1109/bia.1994.315862.
- An automated approach for quantification of relative regional myocardial blood flow, using SPECT Tc99m-sestamibi: preliminary validation in a canine modelLiu Y, Sinusas A, Shi C, Shen M, Dione D, Duncan J, Wackers F. An automated approach for quantification of relative regional myocardial blood flow, using SPECT Tc99m-sestamibi: preliminary validation in a canine model 1994, 1: 636-638 vol.1. DOI: 10.1109/iembs.1994.411839.
- Myocardial risk area defined by technetium-99m sestamibi imaging during percutaneous transluminal coronary angioplasty: Comparison with coronary angiographyHaronian H, Remetz M, Sinusas A, Baron J, Miller H, Cleman M, Zaret B, Wackers F. Myocardial risk area defined by technetium-99m sestamibi imaging during percutaneous transluminal coronary angioplasty: Comparison with coronary angiography Journal Of The American College Of Cardiology 1993, 22: 1033-1043. PMID: 8409038, DOI: 10.1016/0735-1097(93)90413-u.
- Experimental studies of the physiologic properties of technetium-99m isonitrilesBeller G, Sinusas A. Experimental studies of the physiologic properties of technetium-99m isonitriles The American Journal Of Cardiology 1990, 66: e5-e8. PMID: 2145747, DOI: 10.1016/0002-9149(90)90605-z.
- Cardiac imaging with technetium 99m-labeled isonitrilesSinusas A, Beller G, Watson D. Cardiac imaging with technetium 99m-labeled isonitriles Journal Of Thoracic Imaging 1990, 5: 20-30. PMID: 2194038, DOI: 10.1097/00005382-199007000-00006.
- Technetium-99m isonitrile and Thallium-201 activity are comparable following 3 hours of low flow ischemiaSinusas A, Bergin J, Edwards N, Watson D, Ruiz M, Beller G. Technetium-99m isonitrile and Thallium-201 activity are comparable following 3 hours of low flow ischemia Journal Of The American College Of Cardiology 1990, 15: a8. DOI: 10.1016/0735-1097(90)91751-f.
- Influence of subendocardial ischemia on transmural myocardial functionEdwards N, Sinusas A, Bergin J, Ruiz M, Beller G. Influence of subendocardial ischemia on transmural myocardial function Journal Of The American College Of Cardiology 1990, 15: a207. DOI: 10.1016/0735-1097(90)92543-b.
- Quantitative spect isonitrile imaging accurately defines the “area at risk” during coronary occlusionSinusas A, Smiths W, Watson D, Bergin J, Ruiz M, Weber K, Sklenar J, Beller G. Quantitative spect isonitrile imaging accurately defines the “area at risk” during coronary occlusion Journal Of The American College Of Cardiology 1990, 15: a227. DOI: 10.1016/0735-1097(90)92626-d.
- Effect of ischemia and postischemic dysfunction on myocardial uptake of technetium-99m-labeled methoxyisobutyl isonitrile and thallium-201Sinusas A, Watson D, Cannon J, Beller G. Effect of ischemia and postischemic dysfunction on myocardial uptake of technetium-99m-labeled methoxyisobutyl isonitrile and thallium-201 Journal Of The American College Of Cardiology 1989, 14: 1785-1793. PMID: 2584570, DOI: 10.1016/0735-1097(89)90034-x.
- Pathoanatomic correlates of regional left ventricular wall motion assessed by equilibrium radionuclide angiocardiography: A postmortem correlationSinusas A, Hardin N, Clements J, Wackers F. Pathoanatomic correlates of regional left ventricular wall motion assessed by equilibrium radionuclide angiocardiography: A postmortem correlation The American Journal Of Cardiology 1984, 54: 975-981. PMID: 6496360, DOI: 10.1016/s0002-9149(84)80128-9.