2024
Pulsed nicotine infusions as a model for smoking: validating a tool to explore nicotine thresholds in humans
Parida S, MacLean R, Gueorguieva R, Sofuoglu M. Pulsed nicotine infusions as a model for smoking: validating a tool to explore nicotine thresholds in humans. Psychopharmacology 2024, 241: 1915-1922. PMID: 38970644, DOI: 10.1007/s00213-024-06609-6.Peer-Reviewed Original ResearchDiscriminative stimulus effectsAddiction thresholdNicotine doseDiscriminative stimulus effects of nicotineStimulus effects of nicotineNicotine deliveryEffects of nicotineOvernight abstinenceStimulus effectsNicotine infusionSubjective effectsTest sessionsNicotineMethodsEleven participantsInfusion procedureLow dosesParticipantsThreshold doseConclusionsTheseAbstinenceDoseHeart rateInfusionSmokingObjectivesToDiagnostic Accuracy of Pediatrician-performed Digital Retinal Imaging with 3nethra neo for ROP Screening
Garg A, Kumar J, Katoch D, Dutta S, Kumar P. Diagnostic Accuracy of Pediatrician-performed Digital Retinal Imaging with 3nethra neo for ROP Screening. Indian Journal Of Pediatrics 2024, 92: 605-611. PMID: 38372940, DOI: 10.1007/s12098-024-05042-z.Peer-Reviewed Original ResearchConceptsWide-field digital retinal imagingRetinopathy of prematurityBinocular indirect ophthalmoscopyNegative likelihood ratioRetinopathy of prematurity screeningPositive likelihood ratioDiagnostic accuracySeverity of retinopathy of prematurityDigital retinal imagesDetect retinopathy of prematurityReference standardDiagnostic odds ratioLikelihood ratioRetinal imagesIndirect ophthalmoscopyTrained ophthalmologistsAdverse eventsDiagnosing retinopathyDe-identified imagesOphthalmologistsTreatmentObjectivesToPediatriciansResultsThe analysisReferral
2019
Added value of apparent diffusion coefficient in distinguishing between serous and mucin-producing pancreatic cystic neoplasms
Pandey P, Pandey A, Shao N, Varzaneh F, Ghasabeh M, Zharghampour M, Khoshpouri P, Fouladi D, Eng J, O’Broin-Lennon A, Canto M, Hruban R, Kamel I. Added value of apparent diffusion coefficient in distinguishing between serous and mucin-producing pancreatic cystic neoplasms. European Radiology 2019, 29: 4660-4669. PMID: 30762111, DOI: 10.1007/s00330-019-6010-9.Peer-Reviewed Original ResearchConceptsPancreatic cystic neoplasmsApparent diffusion coefficientApparent diffusion coefficient measurementsDiffusion-weighted imagingCystic neoplasmsManagement of pancreatic cystic neoplasmsMorphological MRIValue of apparent diffusion coefficientAbdominal MRIEvaluate MRIDiagnostic confidenceDiagnostic performanceDiagnostic accuracyOdds ratioMRILogistic regressionNeoplasmsPatientsObjectivesToMorphological imaging
This site is protected by hCaptcha and its Privacy Policy and Terms of Service apply