2021
Fat-saturated dark-blood cardiac T2 mapping in a single breath-hold
Hu C, Huber S, Nguyen V, Baldassarre L, Mojibian H, Peters D. Fat-saturated dark-blood cardiac T2 mapping in a single breath-hold. Magnetic Resonance Imaging 2021, 81: 24-32. PMID: 34044065, DOI: 10.1016/j.mri.2021.05.004.Peer-Reviewed Original ResearchBreath HoldingHumansImage Interpretation, Computer-AssistedMagnetic Resonance ImagingPericardiumPhantoms, ImagingReproducibility of Results
2018
REPAIRit: Improving Myocardial Nulling and Ghosting Artifacts of 3D Navigator‐Gated Late Gadolinium Enhancement Imaging During Arrhythmia
Hu C, Huber S, Latif SR, Santacana‐Laffitte G, Mojibian HR, Baldassarre LA, Peters DC. REPAIRit: Improving Myocardial Nulling and Ghosting Artifacts of 3D Navigator‐Gated Late Gadolinium Enhancement Imaging During Arrhythmia. Journal Of Magnetic Resonance Imaging 2018, 49: 688-699. PMID: 30252987, DOI: 10.1002/jmri.26284.Peer-Reviewed Original Research
2017
Reverse double inversion‐recovery: Improving motion robustness of cardiac T2‐weighted dark‐blood turbo spin‐echo sequence
Hu C, Huber S, Latif SR, Santacana‐Laffitte G, Mojibian HR, Baldassarre LA, Peters DC. Reverse double inversion‐recovery: Improving motion robustness of cardiac T2‐weighted dark‐blood turbo spin‐echo sequence. Journal Of Magnetic Resonance Imaging 2017, 47: 1498-1508. PMID: 29112315, PMCID: PMC6346424, DOI: 10.1002/jmri.25886.Peer-Reviewed Original ResearchAdultAgedAlgorithmsArtifactsComputer SimulationDiastoleFemaleHealthy VolunteersHeartHeart DiseasesHeart VentriclesHumansImage EnhancementImage Interpretation, Computer-AssistedImage Processing, Computer-AssistedMagnetic Resonance ImagingMaleMiddle AgedMotionMyocardiumProspective StudiesQuality ControlReproducibility of ResultsSignal-To-Noise Ratio
2016
T1-refBlochi: high resolution 3D post-contrast T1 myocardial mapping based on a single 3D late gadolinium enhancement volume, Bloch equations, and a reference T1
Hu C, Sinusas AJ, Huber S, Thorn S, Stacy MR, Mojibian H, Peters DC. T1-refBlochi: high resolution 3D post-contrast T1 myocardial mapping based on a single 3D late gadolinium enhancement volume, Bloch equations, and a reference T1. Journal Of Cardiovascular Magnetic Resonance 2016, 19: 63. PMID: 28821300, PMCID: PMC5563030, DOI: 10.1186/s12968-017-0375-1.Peer-Reviewed Original ResearchAlgorithmsAnimalsCardiomyopathiesComputer SimulationContrast MediaFeasibility StudiesFemaleFibrosisHeart AtriaHumansImage Interpretation, Computer-AssistedImaging, Three-DimensionalMagnetic Resonance ImagingMaleMiddle AgedModels, CardiovascularMonte Carlo MethodOrganometallic CompoundsPhantoms, ImagingPredictive Value of TestsReproducibility of ResultsSus scrofa