2000
Effect of left ventricular volume on results of coronary artery bypass grafting
Kim R, Ugurlu B, Tereb D, Wackers F, Tellides G, Elefteriades J. Effect of left ventricular volume on results of coronary artery bypass grafting. The American Journal Of Cardiology 2000, 86: 1261-1264. PMID: 11090805, DOI: 10.1016/s0002-9149(00)01216-9.Peer-Reviewed Original ResearchConceptsCoronary artery bypassArtery bypassSignificant left ventricular dilationLeft ventricular dilationLV chamber sizeLV ejection fractionMedium-term survivalSurgical revascularizationAngina symptomsEjection fractionIschemic cardiomyopathyLV dilationVentricular dilationVentricular sizeVentricular volumePatientsSignificant reductionBypassChamber sizeDilationRevascularizationCardiomyopathySymptoms
1997
Effect of left ventricular function on the assessment of myocardial viability by technectium-99m sestamibi and correlation with positron emission tomography in patients with healed myocardial infarcts or stable angina pectoris, or both
Arrighi J, Ng C, Dey H, Wackers F, Soufer R. Effect of left ventricular function on the assessment of myocardial viability by technectium-99m sestamibi and correlation with positron emission tomography in patients with healed myocardial infarcts or stable angina pectoris, or both. The American Journal Of Cardiology 1997, 80: 1007-1013. PMID: 9352969, DOI: 10.1016/s0002-9149(97)00594-8.Peer-Reviewed Original ResearchConceptsCoronary artery diseasePositron emission tomographyLV dysfunctionArtery diseaseGroup 2Myocardial viabilityGroup 1Ejection fractionModerate coronary artery diseaseEmission tomographyModerate LV dysfunctionSevere LV dysfunctionStable angina pectorisLV ejection fractionGlobal LV dysfunctionAccuracy of technetiumSingle photon emissionSemiquantitative SPECTVentricular dysfunctionViability detectionAngina pectorisVentricular functionReduced perfusionSestamibi SPECTMyocardial infarct
1992
Assessment of global and regional left ventricular performance at rest and during exercise after thrombolytic therapy for acute myocardial infarction: Results of the Thrombolysis in Myocardial Infarction (TIMI) II study
Zaret B, Wackers F, Terrin M, Ross R, Weiss M, Slater J, Morrison J, Bourge R, Passamani E, Knatterud G, Braunwald E, Investigators. Assessment of global and regional left ventricular performance at rest and during exercise after thrombolytic therapy for acute myocardial infarction: Results of the Thrombolysis in Myocardial Infarction (TIMI) II study. The American Journal Of Cardiology 1992, 69: 1-9. PMID: 1729855, DOI: 10.1016/0002-9149(92)90667-n.Peer-Reviewed Original ResearchConceptsLV ejection fractionLeft ventricular performanceEjection fractionRegional left ventricular performanceRegional ejection fractionHospital dischargeThrombolytic therapyVentricular performanceTreatment strategiesStrategies patientsComparable work loadNormal exercise responseRegional LV performanceMyocardial Infarction (TIMI) II trialAcute myocardial infarctionHospital-discharged patientsConservative strategyII studyII trialDischarge patientsConservative patientsClinical benefitLV performanceExercise studiesMyocardial infarction
1991
Validation of continuous radionuclide left ventricular functioning monitoring in detecting silent myocardial ischemia during balloon angioplasty of the left anterior descending coronary artery
Kayden D, Remetz M, Cabin H, Deckelbaum L, Cleman M, Wackers F, Zaret B. Validation of continuous radionuclide left ventricular functioning monitoring in detecting silent myocardial ischemia during balloon angioplasty of the left anterior descending coronary artery. The American Journal Of Cardiology 1991, 67: 1339-1343. PMID: 2042565, DOI: 10.1016/0002-9149(91)90462-t.Peer-Reviewed Original ResearchConceptsSilent myocardial ischemiaLV ejection fractionLV dysfunctionMyocardial ischemiaEjection fractionLV functionBalloon inflationRelative end-systolic volumeTransient ST-segment depressionPercutaneous transluminal coronary angioplastyMean LV ejection fractionST-segment depressionContinuous electrocardiographic monitoringTransluminal coronary angioplastyLeft ventricular functionST-segment changesEnd-diastolic volumeEnd-systolic volumeIschemic decreaseCoronary angioplastyVentricular functionElectrocardiographic changesElectrocardiographic monitoringBalloon angioplastyCoronary artery
1982
Radionuclide Assessment of Left Ventricular Function in Patients Requiring Intraoperative Balloon Pump Assistance
Davies R, Laks H, Wackers F, Berger H, Williams B, Hammond G, Geha A, Gottschalk A, Zaret B. Radionuclide Assessment of Left Ventricular Function in Patients Requiring Intraoperative Balloon Pump Assistance. The Annals Of Thoracic Surgery 1982, 33: 123-131. PMID: 7065774, DOI: 10.1016/s0003-4975(10)61896-6.Peer-Reviewed Original ResearchConceptsLV ejection fractionPerioperative myocardial infarctionIntraaortic balloon pump assistanceLeft ventricular functionEjection fractionMyocardial infarctionPreoperative valuesCardiopulmonary bypassVentricular functionPump assistanceCreatine kinase MB fractionExercise radionuclide studiesIntraaortic balloon assistanceNormal LV responseNew Q wavesLV dysfunctionMyocardial depressionBalloon assistanceLV performancePreoperative measurementsLV responseRadionuclide assessmentQ wavesRadionuclide studiesPatients