Paul Han, PhD
Assistant Professor of Radiology and Biomedical ImagingCards
About
Research
Publications
2024
Multimodality Molecular Imaging of Brain Tumor Using Simultaneous [18F]FET-PET/MRSI
Ma C, Han P, Marin T, Zhuo Y, Shih H, Fakhri G. Multimodality Molecular Imaging of Brain Tumor Using Simultaneous [18F]FET-PET/MRSI. 2024, 00: 1-2. DOI: 10.1109/nss/mic/rtsd57108.2024.10656528.Peer-Reviewed Original ResearchList-mode dataMR spectroscopic imagingSpatial resolutionAccurate brain tumor delineationMR physicsIsotropic resolutionBrain tumor delineationImprove treatment planningSpectroscopic imagingTumor delineationSignal-to-noise ratioIntact blood-brain barrierImaging speedAmino acid radiotracerImaging timeMR signalHigher proliferation activityStructural MRTreatment planningBlood-brain barrierMR spectroscopic imaging dataMolecular imaging of brain tumorsTumor involvementTumor infiltrationTumor marginsPET motion correction using subspace-based real-time MR imaging in simultaneous PET/MR
Mounime I, Marin T, Han P, Ouyang J, Gori P, Angelini E, Fakhri G, Ma C. PET motion correction using subspace-based real-time MR imaging in simultaneous PET/MR. 2024, 00: 1-1. DOI: 10.1109/nss/mic/rtsd57108.2024.10657647.Peer-Reviewed Original ResearchOrdered-subset expectation maximizationMotion correctionGated reconstructionsMotion-corrected PET reconstructionsPET eventsCardiac motion phasesMotion correction methodCardiac motionMotion phaseReconstructed dynamic imagesPET reconstructionReal-time MR imagingSimultaneous PET/MRPatient motionSoft tissue contrastDynamic MR image reconstructionReference phaseMitigate artifactsLow-rank propertyMR image reconstructionPositron emission tomographyManifold learning frameworkSpatial resolutionBlurring artifactsImage reconstructionFree‐breathing 3D cardiac extracellular volume (ECV) mapping using a linear tangent space alignment (LTSA) model
Lee W, Han P, Marin T, Mounime I, Eslahi S, Djebra Y, Chi D, Bijari F, Normandin M, Fakhri G, Ma C. Free‐breathing 3D cardiac extracellular volume (ECV) mapping using a linear tangent space alignment (LTSA) model. Magnetic Resonance In Medicine 2024 PMID: 39402014, DOI: 10.1002/mrm.30284.Peer-Reviewed Original ResearchExtracellular volume mappingContrast agent injectionExtracellular volumeGradient echo readoutECV mapsAgent injectionWhole heartEcho readoutExtracellular volume valuesVoxel-by-voxelInversion recovery sequenceSpatial resolutionScan timeImaging timeIn vivo studiesHealthy volunteersModel-based methodsRecovery sequenceInjectionReadoutFree-breathing 3D cardiac extracellular volume (ECV) mapping using a linear tangent space alignment (LTSA) model
Lee W*, Han P*, Marin T, Mounime IBG, Eslahi SV, Djebra Y, Chi D, Bijari FJ, Normandin MD, El Fakhri G, and Ma C. Free-breathing 3D cardiac extracellular volume (ECV) mapping using a linear tangent space alignment (LTSA) model. Magnetic Resonance in Medicine. 2024; doi: 10.1002/mrm.30284.Peer-Reviewed Original ResearchSparsity Constrained Linear Tangent Space Alignment Model (LTSA) for 3d Cardiac Extracellular Volume Mapping
Mounime I, Lee W, Marin T, Han P, Djebra Y, Eslahi S, Gori P, Angelini E, Fakhri G, Ma C. Sparsity Constrained Linear Tangent Space Alignment Model (LTSA) for 3d Cardiac Extracellular Volume Mapping. 2024, 00: 1-5. DOI: 10.1109/isbi56570.2024.10635692.Peer-Reviewed Original ResearchT)-space dataExtracellular volume mappingIntrinsic low-dimensional manifold structureCardiac tissue propertiesImproved image reconstructionLow-dimensional manifold structureExtracellular volumeFast MRI methodSparsity constraintModel-based methodsSuperior performanceSpace alignmentT1 mappingManifold structureImage reconstructionT)-spacePost-contrast T1 mappingTissue propertiesFree breathingConcentration of contrast agentLongitudinal relaxation timeAlignment modelDynamic MR imagingSparsityAlignment matrix
2023
Attenuation correction for PET imaging using conditional denoising diffusion probabilistic model
Dong Y, Jang S, Han P, Johnson K, Ma C, Fakhri G, Li Q, Gong K. Attenuation correction for PET imaging using conditional denoising diffusion probabilistic model. 2023, 00: 1-1. DOI: 10.1109/nssmicrtsd49126.2023.10338188.Peer-Reviewed Original ResearchDiffusion probabilistic modelGenerative adversarial networkConditional encodingAttenuation correctionDenoising diffusion probabilistic modelLow-level featuresProbabilistic modelAttenuation coefficientAdversarial networkExtract featuresPET/MR systemsEncodingPET acquisitionNovel methodDiffusion encodingMagnetic resonanceImagesPET imagingCorrectionMR imagingUNetAttenuationNetworkFeaturesResonanceB1 inhomogeneity‐corrected T1 mapping and quantitative magnetization transfer imaging via simultaneously estimating Bloch‐Siegert shift and magnetization transfer effects
Jang A, Han P, Ma C, Fakhri G, Wang N, Samsonov A, Liu F. B1 inhomogeneity‐corrected T1 mapping and quantitative magnetization transfer imaging via simultaneously estimating Bloch‐Siegert shift and magnetization transfer effects. Magnetic Resonance In Medicine 2023, 90: 1859-1873. PMID: 37427533, PMCID: PMC10528411, DOI: 10.1002/mrm.29778.Peer-Reviewed Original ResearchConceptsBloch-Siegert shiftBloch-SiegertMagnetization transfer effectsMonte Carlo simulationsSpin-lattice relaxationSpin-bath modelMagnetization transferBinary spin-bath modelCarlo simulationsProton fractionOff-resonance irradiationIn vivo brain studiesBloch simulationsPhantom experimentsMagnetizationEstimationTransmitted fieldQuantitative magnetization transferMethod performanceMT effectSignal equationBalanced Steady-State Free Precession and Radial Sampling for Arterial Spin Labeled Perfusion Imaging
Han P, Marin T, Zhuo Y, Ouyang J, Fakhri G, Ma C. Balanced Steady-State Free Precession and Radial Sampling for Arterial Spin Labeled Perfusion Imaging. Proceedings Of The International Society For Magnetic Resonance In Medicine ... Scientific Meeting And Exhibition. 2023 DOI: 10.58530/2023/0373.Peer-Reviewed Original ResearchDirect estimation of metabolite maps from undersampled k-space data using linear tangent space alignment
Ma C, Marin T, Han P, Fakhri G. Direct estimation of metabolite maps from undersampled k-space data using linear tangent space alignment. Proceedings Of The International Society For Magnetic Resonance In Medicine ... Scientific Meeting And Exhibition. 2023 DOI: 10.58530/2023/0496.Peer-Reviewed Original ResearchArterial spin labeled perfusion imaging with balanced steady-state free precession readout and radial sampling
Han P, Marin T, Zhuo Y, Ouyang J, El Fakhri G, Ma C. Arterial spin labeled perfusion imaging with balanced steady-state free precession readout and radial sampling. Magnetic Resonance Imaging 2023, 102: 126-132. PMID: 37187264, PMCID: PMC10524790, DOI: 10.1016/j.mri.2023.05.005.Peer-Reviewed Original ResearchConceptsOff-resonance effectsBalanced steady-state free precessionPhase-cycling techniqueTemporal SNRBalanced steady-state free precession acquisitionRadial sampling schemeSpoiled gradient-recalled acquisitionRadial samplingCartesian sampling schemeBalanced steady-state free precession readoutK-space dataSampling schemeSpin labelingSteady-state free precessionK-spaceImage readoutBanding artifactsMotion-related artifactsReadoutFree precessionArterial spin labelingImage reconstructionParallel imagingImaging timePerfusion-weighted imaging