2024
Noise-aware dynamic image denoising and positron range correction for Rubidium-82 cardiac PET imaging via self-supervision
Xie H, Guo L, Velo A, Liu Z, Liu Q, Guo X, Zhou B, Chen X, Tsai Y, Miao T, Xia M, Liu Y, Armstrong I, Wang G, Carson R, Sinusas A, Liu C. Noise-aware dynamic image denoising and positron range correction for Rubidium-82 cardiac PET imaging via self-supervision. Medical Image Analysis 2024, 100: 103391. PMID: 39579623, PMCID: PMC11647511, DOI: 10.1016/j.media.2024.103391.Peer-Reviewed Original ResearchImage denoisingPositron range correctionDynamic framesSelf-supervised methodsSuperior visual qualityLow signal-to-noise ratioCardiac PET imagingDenoising methodSignal-to-noise ratioSelf-supervisionVisual qualityHigh-energy positronsRange correctionsDenoisingNoise levelImage spatial resolutionImage qualityDefect contrastPET imagingImage quantificationRadioactive isotopesPatient scansQuantitative accuracyImagesFrame
2020
A pilot study of 13N-ammonia cardiac PET imaging to assess subacute cardiotoxicity following adjuvant intensity-modulated radiotherapy for locally advanced breast cancer
Nehmeh S, Fox J, Schwartz J, Ballangrud Å, Schöder H, Zhao Y, Strauss H, Yu A, Gupta D, Powell S, Ho A. A pilot study of 13N-ammonia cardiac PET imaging to assess subacute cardiotoxicity following adjuvant intensity-modulated radiotherapy for locally advanced breast cancer. Clinical Imaging 2020, 68: 283-290. PMID: 32919154, PMCID: PMC8207896, DOI: 10.1016/j.clinimag.2020.07.026.Peer-Reviewed Original ResearchConceptsRate-pressure productMyocardial flow reserveLABC patientsChest wallMyocardial segmentsAdjuvant intensity-modulated radiotherapyCardiac PET imagingPET imagingRadiotherapy treatment positionAdvanced breast cancerRegional lymph nodesBreast cancer patientsTreatment positionIntensity-modulated radiotherapySubacute cardiotoxicityHeart doseRT doseBlood pressureLymph nodesCoronary territoriesBC patientsCancer patientsCardiac functionBreast cancerFlow reserve
2019
MR-based cardiac and respiratory motion correction of PET: application to static and dynamic cardiac 18F-FDG imaging
Petibon Y, Sun T, Han P, Ma C, Fakhri G, Ouyang J. MR-based cardiac and respiratory motion correction of PET: application to static and dynamic cardiac 18F-FDG imaging. Physics In Medicine And Biology 2019, 64: 195009. PMID: 31394518, PMCID: PMC7007962, DOI: 10.1088/1361-6560/ab39c2.Peer-Reviewed Original ResearchConceptsMR-based motion correctionRespiratory motion correctionMotion correctionImproved spatial resolutionReconstructed activity concentrationCardiac PET dataSpatial resolutionCoincidence eventsMR-basedPET imagingContrast-to-noise ratioCardiac PET imagingRespiratory phasesMC dataImprove image qualityMR acquisitionQuantitative accuracyCardiac PETPET dataActivity concentrationsMyocardium wallF-FDG PETDynamics studiesImage qualityMotion artifactsBulk motion detection and correction using list-mode data for cardiac PET imaging
Sun T, Petibon Y, Han P, Ma C, Kim S, Alpert N, Fakhri G, Ouyang J. Bulk motion detection and correction using list-mode data for cardiac PET imaging. Proceedings Of SPIE--the International Society For Optical Engineering 2019, 11072: 110722f-110722f-5. DOI: 10.1117/12.2534701.Peer-Reviewed Original ResearchList-mode dataCardiac PET imagingPET list-mode dataMotion-corrected imagesLines of responsePET imaging applicationsCardiac PETImage qualityBulk motionCardiac PET studiesMotion correctionPET imagingBrain PETMotion estimationData-driven approachMotion detectionImaging applicationsImage spaceMoving frameStatic reference frameMotion transformationCorrectionCenter positionMotionReference frame